Submittal Sheet
Submittal Data:ASU9RLS2 9,000 BTU Wall Mount Type
Inverter Driven Heat Pump
Job Name:______________________________ Date:_______________________________
Location:_______________________________ Approval:____________________________
Engineer:_______________________________ Construction:_________________________
Submitted to:____________________________ Unit #:______________________________
Submitted by:___________________________ Drawing #:___________________________
Reference:______________________________
Model Information
Evaporator…………………………….……..…………...………….… ASU9RLS2
Condenser compatibility………………………….… AOU9RLS2, AOU18RLXFZ
AOU24RLXFZ, AOU36RLXFZ, AOU48RLXFZ
Electrical ……………………………………….…........ 208/230V AC 1ph-60Hz
Available Voltage Range……………………..……..….……....… 208/230 +/- 10%
Minimum Circuit Ampacity……………...…………………........…......…... 0.19 A
Full Load Amps………………………………………………………..……. 0.15 A
Input Power ……………………………………….……....…………….……. 16 W
Running Current………………………………………………………..…… 0.14 A
Capacity
Nominal Cooling………………….…………...…..…………………... 9,000 Btu/h
Fan Motor
Type: DC ……………………………..……………………………... Cross flow x1
Motor Output………………………………………………………….…...…. 36 W
Fan Motor Protection……………………………...… off: 320 ± 45°F (160 ± 25°C)
Airflow Rate on: 230 ± 45°F (110 ± 25°C)
Cooling (High / Medium / Low / Quiet)
353 CFM (600 m3/h) / 324 CFM (550 m3/h) / 277 CFM (470 m3/h) / 194 CFM (330 m3/h)
Heating (High / Medium / Low / Quiet)
353 CFM (600 m3/h) / 324 CFM (550 m3/h) / 277 CFM (470 m3/h) / 194 CFM (330 m3/h)
Heat Exchanger
Dimensions
(H x W x D) in. (mm)………...……..……. 12-5/8 x 27-3/16 x 13/16 (320x690x20)
Fin Pitch……………………………………...…...…..… Main 23 FPI / Sub 18 FPI
Rows x Stages………………………………………………. Main 2 x20 / Sub 1 x4
Pipe Type (Material)………....………………...………………………....… Copper
Type (Material)……………………..…………...……............................. Aluminum
Note: Specifications are based on the following conditions.
Cooling: Indoor temperature of 80°F (26.7°C) DB/67°F (19.44°C) WB, and outdoor temperature of 95°F (35°C) DB/75°F (23.9°C) WB.
Heating: Indoor temperature of 70°F (21.11°C) DB/59°F (15.°C) WB, and outdoor temperature of 47°F (8.33°C) DB/43°F (6.11°C) WB.
Pipe length: 24ft. 7in. (7.5m), Height difference: 0ft. (0m) (Outdoor unit – indoor unit)
•Refrigerant Type R410A.
•Wired and wireless remote controllers
•Auto changeover
•Weekly timer
•Removable open panel
•Super quiet operation
Temperature Setting Range
Cooling…………...………….…………….……..…… 64°F - 90°F (18°C – 32 °C)
Heating………………………………………….……… 60°F - 88°F (16°C - 30°C)
Enclosure
Material………………………………………...……...……Galvanized Steel Sheet
Sound Pressure Level
Cooling
High/Medium/Low/Quiet….........… 36 dB (A) / 32 dB (A) / 28 dB (A) / 21 dB (A)
Heating
High/Medium/Low/Quiet…………. 36 dB (A) / 32 dB (A) / 28 dB (A) / 21 dB (A)
Dimensions
H x W x D
in. (mm)..................................................... 11-1/8 x 34-1/4 x 7-5/16 (282x870x185)
Connection Pipe
Liquid……………………...………..……………..…..……...… 1/4” in. (6.35 mm)
Gas………………………..….....……………….………….…... 3/8” in. (9.52 mm)
Method (Liquid/Gas)………………...…..........………..…...……………....… Flare
Drain hose
Material…………………….…………………………………….…… PP + LLDPE
Size……….…. Ø9/16 (I.D.), Ø5/8 to Ø11/16 [Ø13.8 (I.D.), Ø15.8 to Ø16.7 O.D.)]
Weight
Net……………………...………………………...………………… 21 lbs. (9.5 kg)
Gross…………………........…………………………….……...…… 27 lbs. (12 kg)
Accessories
Wired Remote Controller…………………………………...……… UTY-RNNUM
Backlit Display……………….............…………………………….. UTY-RVNUM
Simple Remote Controller…………………….................…………. UTY-RSNUM
Dry Contact Wire Kit……………………………………...………. UTY-XWZXZ5
Interface Kit……………………………………………………...… UTY-TWBXF1
Intertek©ETL Number
ASU9RLS2………..………………………………...………….……………. 91986
Fujitsu General America, Inc.
353 Route 46 West
Fairfield, NJ 07004
Toll Free: 1-888-888-3424
Fax: (973) 836-0447
www.fujitsugeneral.com
General Features
•Removable air filter
•Energy Saving Program
•Program timer
•5 years standard parts warranty
•Eligible for 10 year or 12 year parts
warranty. See warranty statement
for details.
1 of 2