For authorized service personnel only. MANUEL D’INSTALLATION UNITÉ INTÉRIEURE (Type sol) Seulement pour personnel d’entretien autorisé. MANUAL DE INSTALACIÓN UNIDAD DE INTERIOR (Tipo de piso) Únicamente para personal de servicio autorizado. Français INDOOR UNIT (Floor type) Español INSTALLATION MANUAL English AIR CONDITIONER Keep this manual for future reference. Conserver ce manuel pour pouvoir le consulter ultérieurement. Conserve este manual para futura referencia. PART No.
AIR CONDITIONER When Installing... INSTALLATION MANUAL ...In a Ceiling or Wall Make sure the ceiling/wall is strong enough to hold the unit’s weight. It may be necessary to construct a strong wood or metal frame to provide added support. Part No. 9378533066 Indoor unit (Floor type) Contents 1. SAFETY PRECAUTIONS ............................................................................................ 1 2. ABOUT THIS PRODUCT..........................................................................
Name and Shape 2.2. Special tools for R410A refrigerant Tool name Gauge manifold Contents of change Pressure is high and cannot be measured with a conventional (R22) gauge. To prevent erroneous mixing of other refrigerants, the diameter of each port has been changed. It is recommended the gauge with seals -30 inHg to 768 psi (-0.1 to 5.3 MPa) for high pressure. -30 inHg to 551 psi (-0.1 to 3.8 MPa) for low pressure.
EMBEDDING THE INDOOR UNIT IN A WALL 4. ELECTRICAL REQUIREMENT The indoor unit is powered from the outdoor unit or branch box. Do not power indoor unit from separate power source. WARNING Refer to local codes for acceptable cable type. 5. SELECTING THE INSTALLATION LOCATION • When installing a grating, use a grating with narrow upper and lower horizontal bars so that the airflow from the upper and lower air outlets does not contact the bars.
The side panel L, R installation For RIGHT or LEFT piping (1) Firstly, fit the top part of the side panel, and insert top and bottom hooks. (2) 4 screws is attached. (3) The intake grille is attached. Mounting shaft Front panel Unit: in. (mm) Front panel Rope Intake grille FOR LEFT PIPING Side panel L Intake grille Side panel R 2-1/8 (54) 11/16 2-3/16 (18) (56) 11/16 2-3/16 (18) (56) Rope 2-1/8 (54) FOR RIGHT PIPING For RIGHT BOTTOM or LEFT BOTTOM piping Base Unit: in.
The drain hose can be connected at either side of the indoor unit. The unit has been shipped with the drain hose connected at left (viewed from the back of the unit) and the drain cap applied at right. (1) Remove the both side panels. (2) Remove the screw and remove the drain holder from drain pan. (3) Pull out the drain cap. (4) Connect the drain hose to the right, attach the screw and insert the drain cap to the left. WARNING Fix the indoor unit with 4 screws surely.
When using conventional flare tools to flare R410A pipes, the dimension A should be approximately 0.020 in. (0.5 mm) more than indicated in the table (for flaring with R410A flare tools) to achieve the specified flaring. Use a thickness gauge to measure the dimension A. Width across flats flats Pipe Outside Diameter [in. (mm)] Width Across Flats of Flare Nut [in. (mm)] 1/4 (6.35) 11/16 (17) 3/8 (9.52) 7/8 (22) 1/2 (12.70) 1 (26) 5/8 (15.88) 1-1/8 (29) 3/4 (19.05) 1-7/16 (36) 7.1.
. FINISHING 7.3. Conduit mounting method (1) Fasten the indoor unit wire harness to the conduit holder using the lock nut. IMPORTANT: Refer to [7.1. Wiring system diagram] about the length of indoor unit wire harness. (2) Remove the screws, then remove the cable clamper. (3) Connect indoor unit wire harness to the terminal. Refer to the wiring diagram (4) Use the screws to install the cable clamper. (1) Insulate between pipes.
[Operation method] ● For the operation method, refer to the operating manual. ● The outdoor unit may not operate, depending on the room temperature. In this case, keep on pressing the MANUAL AUTO button of the indoor unit for more than 10 seconds. The Operation lamp and Timer lamp will begin to flash simultaneously during cooling test run. Then, heating test run will begin in about three minutes when HEAT is selected by the remote controller operation.
STEP 1 11.5. Connecting cable to control board connector Selecting the Remote Controller Custom Code (1) Connect the cable to the circuit board and hang on the hooks. CN 6 CN 21 (EX. OUT2) CN 20 CN 14 (EX. OUT1) (EX. IN1) Option type Connector No. Wired remote controller Simple remote controller CN 6 CN 14 (EX. IN1) External input External output (operation status) CN 20 (EX. OUT1) External output (error status) CN 21 (EX.
Auto restart Setting record Record any changes to the settings in the following table. Enable or disable automatic restart after a power interruption. (♦... Factory setting) Function Number 40 Setting Value Setting Description 00 Enable 01 Disable Setting Vertical airflow direction range control ♦ Room temperature sensor switching (Only for Wired remote controller) When using the Wired remote controller temperature sensor, change the setting to “Both” (01). (♦...
Room temperature control for wired remote controller sensor Depending on the installed environment, correction of the wire remote temperature sensor may be required. Select the appropriate control setting according to the installed environment. To change this setting, set Function 42 to Both “01”. Ensure that the Thermo Sensor icon is displayed on the remote controller screen. (♦... Factory setting) Function number 92 93 (For cooling) (For heating) Setting value Setting description 00 No correction 0.
(7) (2) (7) (3) (7) (4) (7) (5) (7) (6) (7) (7) (8) (2) (8) (3) (8) (4) (8) (6) (9) (4) (9) (5) (9) (7) (9) (9) (10) (1) (10) (3) (10) (4) (10) (5) (13) (2) Display mode Compressor temp. sensor error Outdoor unit Heat Ex. liquid temp. sensor error Outdoor temp. sensor error Suction Gas temp. sensor error • 2-way valve temp. sensor error • 3-way valve temp. sensor error Heat sink temp. sensor error • Sub-cool Heat Ex. gas inlet temp. sensor error • Sub-cool Heat Ex.