Design and Technical Manual

- (01 - 29) -
FLOOR TYPE
AGU9-15RLF
FLOOR TYPE
AGU9-15RLF
6) Remote controller custom code
(Only for wireless remote controller)
The indoor unit custom code can be changed.
Select the appropriate custom code.
(
... Factory setting)
Function number Setting value Setting description
44
00 A
01 B
02 C
03 D
7) External input control
"Operation/Stop" mode or "Forced stop" mode can be selected.
(
. . .Factory setting)
Function number Setting value Setting description
46
00 Operation/Stop mode
01 (Setting prohibited)
02 Forced stop mode
8) Room temperature sensor switching (Aux.)
To use the temperature sensor on the wired remote controller only, change the setting to
"Wired remote controller" (01). This function will only work if the function setting 42 is set at
"Both" (01).
(
. . .Factory setting)
Function number Setting value Setting description
48
00 Both
01 Wired remote controller
9) Indoor unit fan control for energy saving for cooling
Enables or disables the power-saving function by controlling the indoor unit fan rotation when
the outdoor unit is stopped during cooling operation.
(
. . .Factory setting)
Function number Setting value Setting description
49
00 Disable
01 Enable
00: When the outdoor unit is stopped, the indoor unit fan operates continuously following the setting on the
remote controller.
01: When the outdoor unit is stopped, the indoor unit fan operates intermittently at a very low speed
.