FR-RLRL45US Operating Manual FR-RLRL45US Operating Manual Document Reference Company: Version: Document Status: Issue Data: Department: Author Manager: Fiber Radio Technologies Ver 2.2 Release 1 2017. 01. R&D Division Team 4 Jun-Hyun Lee PRIVATE AND CONFIDENTIAL © 2016 FRTEK CO., LTD.
FR-RLRL45US Operating Manual ▪ Copyright ⓒ FRTek Co., Ltd. All rights reserved The customer hereby agrees that the use, sale, license or other distribution of this service manual for any such application without the prior written consent of FRTek, shall be at the customer’s sole risk. Without any authorization, the disclosure, distribution, reproduction and reuse of all or part of the information in this service manual to the 3rd party are strictly prohibited.
FR-RLRL45US Operating Manual Revision History Version Issue Date Details of Revision Author V 1.0 16. 08. 19. Original Jun-Hyun Lee V 2.0 16. 10. 03. Revision Jun-Hyun Lee V 2.1 16. 10. 19. Revision Jun-Hyun Lee V 2.2 17. 01. 03. Revision Jun-Hyun Lee Authorizing Manager This manual is produced by R&D Division Team 4 Printed in FRTek. PRIVATE AND CONFIDENTIAL © 2016 FRTEK CO., LTD.
FR-RLRL45US Operating Manual Contents Chapter 1 Safety & Certification Notice ............................................................................................. 7 1.1 FCC Warning Statements ............................................................................................................. 8 1.1.1 FCC Part 15.105 statement .................................................................................................... 8 1.1.2 FCC Part 15.21 statement ..............................
FR-RLRL45US Operating Manual Figures Figure 1. ICS Repeater Service Application Network ......................................................................... 11 Figure 2. Repeater Figuration .............................................................................................................. 14 Figure 3. ICS Repeater External Port Configuration ......................................................................... 15 Figure 4. AC Power Cable .................................................
FR-RLRL45US Operating Manual Used Abbreviations ACLR Adjacent Channel Leakage Power Ratio ALC Auto Level Control EVM Error Vector Magnitude GUI Graphical User Interface HPA High Power Amp HAAT Height Above Average Terrain ICS Interference Cancellation System PSU Power Supply Unit SISO Single Input Single Output VSWR Voltage Standing Wave Ratio USB Universal Serial Bus 3GPP 3rd Generation Partnership Project EMS Enetrprise Management Systems RET Remote Electric Tilt PRIVATE AND C
FR-RLRL45US Operating Manual Chapter 1 Safety & Certification Notice 1.1 Health and Safety Warnings PRIVATE AND CONFIDENTIAL © 2016 FRTEK CO., LTD.
FR-RLRL45US Operating Manual Safety & Certification Notice 1.1 FCC Warning Statements 1.1.1 FCC Part 15.105 statement - This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. - These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
FR-RLRL45US Operating Manual Booster Warning Label WARNING. This is NOT a CONSUMER device. It is designed for installation by FCC LICENSEES and QUALIFIED INSTALLERS. You MUST have an FCC LICENSE or express consent of an FCC License to operate this device. Unauthorized use may result in significant forfeiture penalties, including penalties in excess of $100,000 for each continuing violation. PRIVATE AND CONFIDENTIAL © 2016 FRTEK CO., LTD.
FR-RLRL45US Operating Manual Chapter 2 System Overview 2.1 System Overview PRIVATE AND CONFIDENTIAL © 2016 FRTEK CO., LTD.
FR-RLRL45US Operating Manual System Overview 2.1 System Overview FRTek’s repeater is the most economical and effective solution for outdoor coverage with high RF efficiency and robust feedback cancellation. ICS repeater receives 1900MHz CDMA and LTE RF signal from BTS and transmits them to service user after amplifying to expand CDMA/LTE service coverage and cover shadow regions with black spot where BTS installation is not available.
FR-RLRL45US Operating Manual UL 1850 ~ 1915 MHz DL 30Watt/Total (44.77dBm /Total) UL 2Watt/Total (33dBm /Total) System Output AC Power AC 110V ~ 240V Enclosure Size Below 24" x 19" x 15" Weight Below 35kg Excluding mounting bracket ※ Maximum DL output power is 30Watt/Total - In case of 3 blocks : 10Watt (40dBm) per block - In case of 2 blocks : 15Watt (41.76dBm) per block - In case of 1 block : 20Watt (43.01dBm) per block ※ Maximum UL output power is 2Watt/Total - In case of 3 blocks : 0.
FR-RLRL45US Operating Manual Chapter 3 System Configuration 3.1 Configuration 3.2 System Module Configuration 3.3 System Port Configuration 3.4 AC Power Cable 3.5 Antenna PRIVATE AND CONFIDENTIAL © 2016 FRTEK CO., LTD.
FR-RLRL45US Operating Manual System Configuration 3.1 System Figuration This equipment is designed with consideration the following items: - Enclosure of the equipment is designed for outdoor environments and for handling such as rainfall, snowfall and temperature change. - This equipment is designed to carry, assemble, install easily. - Enclosure of this equipment is designed to protect breaking into dust, pollutants and insect.
FR-RLRL45US Operating Manual 3.2 System Module Configuration Module Name Q’ty Description Duplexer 2 There are 2 types for donor and server and it support to divide DL/UL signal. DL HPA 1 It amplifies output of DL Signal from ICS Module. UL HPA 1 It amplifies output of UL Signal from ICS Module. ICS Module 1 It performs ICS signal processing after receiving main signal and feedback signal to and also embedded MCU and performs MCU function.
FR-RLRL45US Operating Manual Port Type AC IN Port (For supplying AC PORT) Donor Antenna Server Antenna DL MON UL MON RET (AISG 2.0) Local GUI Description Location of port AC(110~204V) is provided from external power cabinet. Spec : MS3106A-16-10S(Female) Connection port with link antenna, it receives and transmit BTS(BS) signal through this port. Spec : 7/16 DIN-Female Connection port with server antenna, it receives and transmit Mobile(MS) signal through this port.
FR-RLRL45US Operating Manual 3.5 Antenna One of the important system optimizations task is to adjust antenna tilts, or the inclination of the antenna in relation to an axis. By doing tilt adjustment, we are able to control the received RF power to concentrate the energy into the new desired direction. FR-RLRL45US Repeater has RET function to adjust antenna tile. Figure 5. RET Port Connector(SU-20SPR-8S) Pin Map Part 27.50 Antennas must be installed in accordance with FCC 27.50.
FR-RLRL45US Operating Manual Chapter 4 System Specification 4.1 RF Specification 4.2 Power Specification 4.3 Environment Specification PRIVATE AND CONFIDENTIAL © 2016 FRTEK CO., LTD.
FR-RLRL45US Operating Manual System Specification 4.1 RF Specification Items Specification Remark Service Frequency LTE, CDMA2000/EV-DO LTE 5M / 10M DL CDMA 1930 ~ 1995 MHz UL CDMA 1850 ~ 1915 MHz Frequency band Occupied Bandwidth 25 MHz configurable ( 3 channels contiguous and or non-contiguous) in 5MHz increments. ≤ 3dB Band Flatness Frequency Stability CDMA LTE (5M / 10M) CDMA p-p ≤ ±0.05ppm Rho ≥ 0.99 EVM ≤ 3.2% EVM ≤ 5.1% EVM ≤ 7.1% Rho ≥ 0.
FR-RLRL45US Operating Manual This system complies with prescribed gain control and input/output function specification. Items Specification Remark Gain control range 65 ~ 105 dB DL / UL Gain control gap 0.5 dB /Step Gain control error Below ±0.5dB /Step DL -60.3dBm/Total UL -72dBm/Total Input Range DL Output Level UL DL Shut-down Function UL System Noise Figure 30Watt/Total (44.7dBm /Total) 2Watt/Total (33dBm /Total) Over 45.
FR-RLRL45US Operating Manual 4.2 Power Specification Items Specification Power AC110 ~ 240V, 60Hz 4.3 Environment Specification 4.3.1 This system operates in operating temperature between -40°C ~ +55°C without problem. 4.3.2 After testing the temperature/humidity test, there is no condensation inside of the system. 4.3.3 In terms of not operating system, there is not condensation and function degradation due to difference of temperature. 4.3.
FR-RLRL45US Operating Manual Chapter 5 FR-RLRL45US Installation 5.1 Installation PRIVATE AND CONFIDENTIAL © 2016 FRTEK CO., LTD.
FR-RLRL45US Operating Manual FR-RLRL45US Installation 5.1 Installation 5.1.1 Grounding Connection Figure 6. Connection of grounding cable This system connects with enclosure grounding and building ground to avoid electrical hazard and protect system operator. 5.1.2 Antenna Connection Figure 7. ICS Antenna Cable Connection. PRIVATE AND CONFIDENTIAL © 2016 FRTEK CO., LTD.
FR-RLRL45US Operating Manual Donor and Server Antenna have RF and RET ports, and these ports are connected to ICS repeater. The brief drawing which connectors to the antenna of ICS repeater is as follows. Antenna being used for ICS repeater should be approved by service provider or officially approved and proper antenna type can be selective depending on the installation environment. This system is composed of 2 antenna port (Donor and server antenna) it is DIN-Type Connector.
FR-RLRL45US Operating Manual FR-RLRL45US Operating Manual Fiber Radio Technologies CO., LTD. All rights reserved. - Copyright ⓒ FRTek Co., Ltd. All rights reserved. - Without any authorization of FRTek Co., Ltd., the disclosure, distribution, reproduction and reuse of all or part of the information in this service manual to the 3rd party are strictly prohibited . PRIVATE AND CONFIDENTIAL © 2016 FRTEK CO., LTD.