INOVA DAS Operating Manual INOVA DAS Operating Manual Document Reference Company: Fiber Radio Technologies Version: Ver 1.2 Document Status: Release 1 Issue Date: 2018. 10. Department: R&D Group 2 Author Manager: Jun Hyun, Lee PRIVATE AND CONFIDENTIAL © 2018 FRTEK CO., LTD.
INOVA DAS Operating Manual ▪ Copyright The copyright of this manual is from FRTek Co., Ltd. This manual may not be reproduced, distributed, modified on any form without the consent of FRTek Co., Ltd Unauthorized disclosure, distribution, copying or use of the information contained in this document in whole or in part without authority is strictly prohibited. ▪ Trademark The trademarks mentioned in this manual are registered trademarks of the respective company.
INOVA DAS Operating Manual Revision History Version Issue Date Details of Revision Author Authorizing Manager V 1.0 18. 09. 12. Original Jun Hyun, Lee V 1.1 18. 10. 17. 1st Revision Jun Hyun, Lee V 1.2 18. 10. 22. 2nd Revision Jun Hyun, Lee This manual is produced by R&D Group 2 Printed in FRTek. PRIVATE AND CONFIDENTIAL © 2018 FRTEK CO., LTD.
INOVA DAS Operating Manual Chapter 1 Safety & Certification Notice 1.1 FCC/IC WarningStatements PRIVATE AND CONFIDENTIAL © 2018 FRTEK CO., LTD.
INOVA DAS Operating Manual Safety & Certification Notice 1.1 FCC/IC Warning Statements 1.1.1 FCC Part 15.105 statement - This equipment has been tested and found to comply with the limits for a Class A digital device. - These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
INOVA DAS Operating Manual work in order to prevent door from slamming due to wind causing bodily harm or damage. - Due to power dissipation, the remote unit may reach a very high temperature. Do not operate this equipment on or close to flammable materials. Use caution when servicing the unit. - Use this equipment only for the purpose specified by the manufacturer. Do not carry out any modifications or fit any spare parts, which are not sold or recommended by the manufacturer.
INOVA DAS Operating Manual Please be informed that the temperature of the surface is too high. Please be careful. The label is attached to the front of the equipment and the PSU (Power Supply Unit). • [FCC] RF Exposure Statement The antenna(s) must be installed such that a minimum separation distance of at least 20cm is maintained between the radiator (antenna) and all persons at all times. This device must not be colocated or operating in conjunction with any other antenna or transmitter.
INOVA DAS Operating Manual • RF Radiation Exposure This equipment complies with RF radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20 cm between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. RF exposure will be addressed at time of installation and the use of higher gain antennas require larger separation distances.
INOVA DAS Operating Manual Chapter 2 System Overview 2.1 System Overview 2.2 SystemNetworkConfiguration PRIVATE AND CONFIDENTIAL © 2018 FRTEK CO., LTD.
INOVA DAS Operating Manual System Overview 2.1 System Overview INOVA DAS is a system that can provide high quality telecommunication quality and data telecommunication service both in-building and outdoor. Also, this system is a DAS (Distributed Antenna System) system, a digital system capable of accommodating a plurality of frequency bands, available for public and private facilities.
INOVA DAS Operating Manual Chapter 3 System Configuration 3.1 ROU 2W Configuration 3.2 ROU 5W Configuration PRIVATE AND CONFIDENTIAL © 2018 FRTEK CO., LTD.
INOVA DAS Operating Manual 3.1 ROU 2W Configuration ROU 2W is a structure that can be used in-building, enclosure is minimized considering installation space and operator's convenience. ROU 2W is configured with RPSU, RDTU, RCPU, 6 RRFUs(ROU RF unit) and supports up to 6 frequency bands. Figure 11. ROU 2W Item Content Remark Size 300 * 890 * 262.9 (W * H * D) Including bracket Weight Approx. 39kg Input power AC 120V (60Hz) Environment In-building type Figure 12. ROU 2W Port Configuration.
INOVA DAS Operating Manual No Content ① Bluetooth antenna port ② 1Gbps service port ③ External alarm port ④ MHU/ROU Single OPTIC port ⑤ MHU/ROU Extend OPTIC port ⑥ Reserved OPTIC port (Single Sectorization or 5G interlink) ⑦ Reserved OPTIC port (Extend Sectorization or 5G interlink) ⑧ ANT port ⑨ Coupling port ⑩ AC power input port ⑪ EXT FAN input port PRIVATE AND CONFIDENTIAL © 2018 FRTEK CO., LTD.
INOVA DAS Operating Manual 3.2 ROU 5W Configuration ROU 5W is a structure for in-building and outdoor, minimized enclosure considering installation space and operator's convenience. ROU 5W, same as ROU 2W, is configured with RPSU, RDTU, RCPU, 6 RRFUs (ROU RF unit), and supports up to 6 frequency bands. Also, functions of ROU 5W are the same as ROU 2W. Below picture shows the ROU 5W figure. Figure 13. ROU 5W. Item Content Remark Size 300 * 970 * 287.9 (W * H * D) Including bracket Weight Approx.
INOVA DAS Operating Manual Figure 14. ROU 5W Port Configuration.
INOVA DAS Tune-up Procedure Chapter 3 Bluetooth Connection 3.1 LTD. Bluetooth Connection PRIVATE AND CONFIDENTIAL © 2018 FRTEK CO.
INOVA DAS Tune-up Procedure 3.1 Bluetooth Connection INOVA DAS is implemented with Bluetooth function for user's convenience. ROU is configured with Bluetooth port, and GUI access is available remotely through Bluetooth. Connect Bluetooth antenna to ROU’s Bluetooth port, and turn on the ROU power. Then go to the control panel - hardware and sound - device and printer window, click right button of the mouse and click the add device button.
INOVA DAS Operating Manual Chapter 4 System Installation 4.1 Tools 4.2 ROU 2W Installation 4.
INOVA DAS Operating Manual System Installation “ This manual is to provide product installation method and product information to the user operating the INOVA DAS system, the repeater manager who uses the operation manual needs to require professional knowledge and experience on construction operation of repeater systems. “ This chapter explains how to connect power cables and how to install each equipment and optic cable.
INOVA DAS Operating Manual Other cables and components needed for installation are as below. No. Tools No.
INOVA DAS Operating Manual 4.2 ROU 2W Installation 4.2.1 Product Installation ROU 2W is configured to one enclosure, can be installed to wall through mounting bracket. Figure 1. ROU 2W needed Door space. Since ROU 2W is configured with door, for ease of process, 324mm space on the equipment right side must be secured, and more than 570mm installation space is needed from installation wall. Figure 2. ROU 2W Anchor Bolt Assemble. Above figure is a simple drawing for the wall face.
INOVA DAS Operating Manual Figure 3. ROU 2W Wall Installation Assemble. Above figure is the assemble drawing of ROU 2W's wall installation. The assemble orders are as below. 1. Insert bake lite to M16 Anchor Bolt, and locate ROU 2W according to M16 Anchor Bolt location. 2. Insert M16 Insulation Bushing, M16 Plane Washer, and M16 Spring Washer. 3. Tighten M16 Hex, Nut using spanner. 4.2.2 Ground Cable Connection Figure 4. ROU 2W Ground Cable Connection.
INOVA DAS Operating Manual 4.2.3 Power Cable Connection ROU 2W uses AC120V(60Hz) as main power, and power cable includes plug. Below is the pin specification of AC power cable, when connecting power, polarity of each pin must be checked. MS Connector Pin Name Name Description Length(mm) A AC_H AC Hot 1800 B AC-N AC Neutral 1800 C F.G Frame Ground 1800 Figure 5. ROU 2W의 Power Cable. 4.2.4 Optic Cable Connection Figure 6. ROU 2W Optic Cable Connection.
INOVA DAS Operating Manual 4.3 ROU 5W Installation 4.3.1 Product Installation ROU 5W is configured with one enclosure, installation on wall is available through mounting bracket. Figure 7. ROU 5W Needed Door Space. Since ROU 5W is, same as ROU 2W, configured with door, for ease of process, 324mm space on the equipment right side must be secured, and more than 570mm installation space is needed from installation wall. Figure 8. ROU 5W Anchor Bolt Assemble.
INOVA DAS Operating Manual bolt is used to fix. Figure 9. ROU 5W Wall Face Installation Assemble. Above figure is a assemble drawing of wall face installation of ROU 5W. Assemble order is as the following. 1. Insert bakelite to M16 Anchor Bolt, and locate ROU 5W according to M16 Anchor Bolt location. 2. Insert M16 Insulation Bushing, M16 Plane Washer, and M16 Spring Washer. 3. Tighten M16 Hex, Nut using spanner. 4.3.
INOVA DAS Operating Manual Figure 10. ROU 5W Ground Cable Connection. Same as ROU 2W, Enclosure grounding and building grounding is connected in order to stable and protect ROU 5W equipment from electrical danger. 4.3.3 Power Cable Connection Same as ROU 2W, ROU 5W uses AC power cable, and when connecting power, polarity of each pin must be checked. MS Connector Pin Name Name Description Length(mm) A AC_H AC Hot 1800 B AC-N AC Neutral 1800 C F.G Frame Ground 1800 Figure 11.
INOVA DAS Operating Manual 4.3.4 Optic Cable Connection Figure 12. ROU 5W Optic Cable Connection. Figure 13. ROU 5W Waterproof Type Optic Connector. Since ROU 5W is also installed and operated outdoors, waterproof type optic cable must be used for outdoor use. Above figure shows information of the optic cable connection method and waterproof type optic connector.
INOVA DAS Operating Manual 92