User's Manual

Introduction
Thank you for purchasing the FrSky Horus X10 digital telemetry radio system. In order to make the best use of your
system and to fly safely, please read this manual carefully. If you have any difficulties while using your system, please
consult the manual, your hobby dealer, or FrSky technical support.
Meanings of Special Markings
Pay special attention to safety where indicated by the following marks:
DANGER- Procedures which may lead to dangerous conditions and cause death/serious injury if not carried
out properly.
WARNING- Procedures which may lead to a dangerous condition or cause death or serious injury to the user
if not carried out properly or procedures where the probability of superficial injury or physical damage is high.
CAUTION- Procedures where the possibility of serious injury to the user is small, but there is a danger of injury,
or physical damage, if not carried out properly.
= Mandatory = Prohibited
Warning: Always keep electrical components away from small children.
FrSky Horus X10 Manual
Due to unforeseen changes in production, the information contained in this manual is subject to change without notice.
Cautions on handling antenna of External Module
Do not touch the antenna during operation. Doing so could interfere with transmission, causing a crash.
Do not carry the transmitter by the antenna. The antenna wire could break and prevent transmission.
Do not pull the antenna forcefully. The antenna wire could break and prevent transmission.
Specifications
Model Name: Horus X10
Number of Channels: 47 channels
Operating Voltage: DC 7.2V supplied by battery or DC 15V from adapter
Operating Temperature: -10~60
Industrial screen: high resolution TFT (480*272), readable outdoor
Compatibility: FrSky X series, D series, L series and V8-II series receivers (plus other receivers if an external module
is used)
16MB Flash
*SD card is not supplied with X10 Horus, please purchase separately.
● 6 position encoder for easier flight modes switch
● FrSky FrTX operation system
● Industrial High Resolution TFT Screen Readable
Outdoor
● Internal and External Antenna selectable
Audio Speech Outputs (values, alarms, settings, etc.)
● Full telemetry and real-time data logging
Antenna detection and SWR warning
● 6 ball bearings gimbals with accuracy hall
sensor and extensible by stick ends
● Inbuilt wireless trainer system
Features
Notice:
When failsafe is disabled on X10 Horus side, the failsafe set on receiver side will be used.
SBUS port always outputs, No Pulse could not perform properly on it. Set “Hold” or “Custom” for SBUS port.
The above instructions do not apply to D-series and L-series receivers, which require the internal RF module of
Horus X10 to be in D8 mode or LR12 mode. For these receivers, failsafe must be set on the receiver side
(see receiver instructions).
Notes and Warnings for Battery & Charger
The 2S Li-Ion battery is for use only in your Horus X10.
Be sure to use the offered battery charger to charge the battery.
Be careful not to drop the battery.
Don't pull the battery wires as this could produce, short-circuits and cause the battery to explode.
Do not remove the battery from the Horus X10 transmitter while the voltage warning is blinking as this could
cause internal settings and memories to be destroyed.
Be sure to turn off the Horus X10 before charging the battery.
The Power Indicator LED in the charger will be on during charging, and be off after the charging is finished.
Model Setup for Horus X10 Internal RF Module
The internal RF module of FrSky Horus X10 is newly developed by FrSky under the name of IXJT.
Enter the RF SYSTEM menu (for details, download it from FrSky website).
Model Setup for Horus X10 External RF Module
No Pulse: on loss of signal the receiver produces no pulses on any channel. To use this type, select it in the menu
and wait 9 seconds for the failsafe to take effect.
Hold: the receiver continues to output the last positions before signal was lost. To use this type, select it in the menu
and wait 9 seconds for the failsafe to take effect.
Custom: pre-set to required positions on lost signal. Move the cursor to the failsafe mode of channel and press Encoder,
then choose the Custom mode. Move the cursor to the channel you want to set failsafe on, and press Encoder.
Then rotate the Encoder to the place you want for failsafe and short press Encoder to finish the setting. Wait 9 seconds
before the failsafe takes effect.
Step 6: Range
Range refers to Horus X10 range check mode.
A pre-flight range check should be done before
each flying session. Move the cursor to “STATE”,
scroll the Encoder to select “RANGE” mode and
press Encoder.In range check mode, the effective
distance will be decreased to 1/30. Press “STATE”
turn to “NORMAL” then exit.
The external RF module can be powered on or off by
software. The setup process is the same as that for
the internal RF .
If you use other brand RF module than FrSky, please
choose PPM mode.
Step 2
: Set the Channel Range
The internal RF module of Horus X10 supports 47
channels. The channel range is configurable, and needs
double check before use.
Step 3: Set the Receiver Number
When you create a new model, the system will assign y
ou a receiver number automatically, but this can be
easily changed.
The range of the receiver number is 01-47, with the default number being 01. Once the receiver
is set to the desired number and is bound to the Horus X10, the bind procedure will not need to be repeated
unless the receiver number is changed, In this case, either set the receiver number to the previous one,
repeat the bind procedure.
Step 4: Bind
Bind refers to Horus X10 binding mode. Move the cursor to “STATE”, press Encoder button, scroll the Encoder to
select “BIND” mode and then press Encoder button again, that the RF module has entered the bind mode. Then put
your receiver into binding mode and finish the bind procedure(refer to the receiver’s manual for details).Press
“STATE” turn to “NORMAL” then exit.
Step 5: Set Failsafe mode
There are 3 failsafe modes When enabled :
No Pulse, Hold, Custom.
Compatible Receivers Number of Output Channels
D8
D16
LR12
X series (X8R, etc.)
L series (L9R, etc.)
47 channels
47 channels
47 channels
V8-II series in D mode (V8FR-II,
V8R7-II, V8R4-II, VD5M, etc.)
D series (D8R-II plus, D8R-XP,
D6FR, D4R-II, etc.)
Note: older V8 receivers are not supported by the internal module but can be used with an external
DJT module in V8 mode.
Overview
(Switch Default Settings)
SA: 3 positions, Short Lever
SB: 3 positions, Long Lever
SC: 3 positions, Long Lever
SD: 3 positions, Short Lever
SE: 3 positions, Short Lever
SF: 2 positions, Long Lever
SG: 3 positions, Short lever
SH: 2 positions, Momentary;
Long Lever
You can choose the Switch and define
its positions in the Input and Output
Map screen.
Step 1: Set the Mode for Horus X10 Internal RF
Refer to the table below and set the HORUS X10
to the mode corresponding to your receiver (D8,
D16 or LR12 ).
FrSky Electronic Co., Ltd www.frsky-rc.com Contact us : frsky@frsky-rc.com
Add:F-4,Building C, Zhongxiu Technology Park, No.3 Yuanxi Road, Wuxi, 214125, Jiangsu, China Technical Support: sales4tech@gmail.com
FrSky Electronic Co., Ltd www.frsky-rc.com Contact us : frsky@frsky-rc.com
Add:F-4,Building C, Zhongxiu Technology Park, No.3 Yuanxi Road, Wuxi, 214125, Jiangsu, China Technical Support: sales4tech@gmail.com
FrSky Electronic Co., Ltd www.frsky-rc.com Contact us : frsky@frsky-rc.com
Add:F-4,Building C, Zhongxiu Technology Park, No.3 Yuanxi Road, Wuxi, 214125, Jiangsu, China Technical Support: sales4tech@gmail.com
FrSky Electronic Co., Ltd www.frsky-rc.com Contact us : frsky@frsky-rc.com
Add:F-4,Building C, Zhongxiu Technology Park, No.3 Yuanxi Road, Wuxi, 214125, Jiangsu, China Technical Support: sales4tech@gmail.com
Mode of Horus X10
USB Port
Smart Port
Trainer port
Diaplay Screen
Speaker
Power Swich
SA, SB, SE, SF
Stick
(J3)
(J4)
MDL,SYS,
RTN,TELE,
PgUp/PgDn,
LS
Charge Jack
SC, SD, SG, SH
S1, S2,
Stick
(J1)
(J2)
ENT
RS
Headset port

Summary of content (2 pages)