Product information

YELLOW/
BLACK
YELLOW/
BLACK
YELLOW
YELLOW
BROWN
BLACK
BLUE
BLACK
YELLOW
BLACK
COMPRESSOR
CONTACTOR
OUTDOOR
FAN MOTOR
HIGH PRESSURE
SWITCH
LOW PRESSURE
SWITCH
CCH
S
C
R
HC
Y2 C Y
L1 L2
T2T1
TO THERMOSTAT
LEFT
RIGHT
YELLOW
GRN L1
L2
SINGLE PHASE
FIELD SUPPLY
ECM
Y2
L2
C
L1
Y1
G
RED
BLACK
CAPACITOR
WHITE
C
TERMINAL
BLOCK
D
GREEN
TO UNIT
GROUND
LUG
WIRING DIAGRAM
711013B
(Replaces 711013A)
07/19
FIELD WIRING
LEGEND:
LOW VOLTAGE
HIGH VOLTAGE
YELLOW
BLACK
YELLOW
BLUE
YELLOW
CC- CONTACTOR COIL
CCH - CRANKCASE HEATER
LPS - LOW PRESSURE SWITCH
HPS - HIGH PRESSURE SWITCH
CSC - COMPRESSOR SOLENOID COIL
208/230V
H
C
CCH
R
C
S
L2
T2
COMPRESSOR
CONTACTS
L1
T1
COMPRESSOR
CSC
C
Y2
Y
LPSHPS
COMPRESSOR
SOLENOID COIL
24 VOLT FIELD
CONNECTIONS
CC
208/230V
Two Stage Split System Air Conditioner (Outdoor Section)
With ECM Outdoor Motor
Single Phase / 60 Hz.
NOTES:
1. Disconnect all power before servicing.
2. For supply connections use copper conductors only.
3. Not suitable on systems that exceed 150 volts to ground.
4. For replacement wires use conductors suitable for 105
5. For ampacities and overcurrent protection, see unit rating plate.
6. Connect to 24 vac/40va/class 2 circuit. See furnace/airhandler installation
instructions for control circuit and optional relay/transformer kits.
1. Couper le courant avant
de faire letretien.
2. Employez uniquement des
conducteurs en cuivre.
3. Ne convient pas aux installations
de plus de 150 volt a la terre.
°C
OUTDOOR
FAN MOTOR
CAPACITOR
Y1
C
Y2
ECM
L2
L1
G
TO GROUND
UNIT LUG

Summary of content (1 pages)