All about the Use & Care of your Dehumidifier TA B L E O F C O N T E N T S Important Safety Instructions ............................... 2 Care And Cleaning .............................................. 11 Installation........................................................... 3 Storage ............................................................. 11 Location .............................................................. 3 Before You Call ...................................................
Important Safety Instructions NOTE: This USE & CARE MANUAL provides specific operating instructions for your model. Use the dehumidifier only as instructed in this USE & CARE MANUAL. These instructions are not meant to cover every possible condition and situation that may occur. Common sense and caution must be practiced when installing, operating, and maintaining any appliance. WARNING WARNING Avoid fire hazard or electric shock. Do not use an extension cord or an adaptor plug.
Installation, Location & How It Works Location Selecting a Location IMPORTANT: 1. Dehumidifier must be operated in an enclosed area to be most effective. Close all doors, windows, and other outside openings to the room. The effectiveness of the dehumidifier depends on the rate at which new moisture-laden air enters the room. 2. Place dehumidifier in a location that does not restrict airflow through the rear of the unit. 3.
Operating Instructions Operating Instructions Allow the unit to reach room temperature before operating. To begin operating the dehumidifier, follow these steps: NOTE: Unit must be upright for one hour prior to operating. 1. Plug the power cord into a properly grounded 115 volt AC outlet. NOTE: If the "BUCKET FULL" light is on, remove the bucket and re-install to reset the float switch. CO 2. To turn the unit on, press the ON/OFF button.
Operating Instructions Operating Instructions (continued) 4. You can also use the FAN SPEED button to change the fan speed to HIGH, Medium or LOW. The indicator light will show the setting you have selected. A higher fan speed will result in quicker moisture removal. 65 5. The CLEAN FILTER light will illuminate after 250 hours of operation. At this time refer to the care and cleaning section to remove and clean the filter.
Operating Instructions Operating Instructions (continued) 7. Press PUMP button, the unit will enter water pump mode. Pump Mode Indicator will be on. When the water tank is full of water,the pump will start to pump water automatically. The pump will stop automatically after a set period. NOTE: Pump drain hose must be well connected for this mode. 8. To shut the unit down, press the ON/OFF button.
Fault Codes Fault Codes (continued) 2.If the display reads "F0" , check the following operating conditions. Outlet voltage should be 115V±10% and the surrounding temperature should be with in the range of 41 °F (5 °C) to 90 °F (32 °C). Unplug the unit and plug it in again under normal operating conditions. If the "F0" code persists, contact your Authorized Frigidaire Service Center. F0 3.If the display reads "PU", check the following operating conditions: a.
Operating Instructions Removing Collected Water 1. Emptying the Bucket: a. When the bucket is full, the unit will shut down and the BUCKET FULL indicator will illuminate. The product have also added an additional bucket full indicator light to the front of the unit, this light will continually blink when the bucket is full, removed or not placed correctly. 65 b. Do not move the unit at this time otherwise water may spill on the floor. c. Press sides of bucket gently to unclip the bucket from the unit. d.
Operating Instructions Removing Collected Water (continued) 2. Continuous Drainage: a. Open the drain cover at the side of the unit, so the drainage connector could be found inside. (fig.1) Take out drainage adapter from the top of the styrofoam packaging. (fig.4) NOTE: The drainage adapter is just a helpful tool which facilitates the installation of dehumidifier drain hose (not supplied), however it is not necessary for the operation of the continuous drainage feature.
Operating Instructions Removing Collected Water (continued) NOTE: 1. Screw the hose onto the drainage connector of the unit directly or through the drainage adapter, continuous drainage option will automatically start. 2. Check the seal between the hose and the drainage adapter. If there is a small leak then replace the hose gasket and re-tighten the hose. 3. It is recommended that a Dehumidifier Drain Hose - 11/16" (17.5 mm) or larger be used. 4.
Care and Cleaning & Storage Care and Cleaning Tabs 1. Filter a. Remove the filter every two weeks based on normal operating conditions. b. To remove the filter, pull the tabs and then take out the filter. c. Wash the filter with clean water then dry. Do not dry the air filter with electric hair dryer. d. Once filter is dry, replace on rear of unit and snap in place. 2. Cabinet a. Dust cabinet with an oil-free cloth, or using a damp cloth. b. Vacuum grill using brush attachment. Air Filter 3.
Before You Call Before calling for service, review this list. It may save you time and expense. This list includes common occurrences that are not the result of defective workmanship or materials in this appliance. OCCURRENCE DEHUMIDIFIER DOES NOT OPERATE. SOLUTION Wall plug disconnected. Push plug firmly into wall outlet. House fuse blown or circuit breaker tripped. Replace fuse with time delay type or reset circuit breaker. The dryness level you selected has been reached.
Major Appliance Limited Warranty Your appliance is covered by a limited one-year warranty and a limited 2-5 year warranty on the sealed system (the compressor, condenser, evaporator and tubing). For one year from your original date of purchase, Electrolux will pay all costs for repairing or replacing any parts of this appliance that prove to be defective in materials or workmanship when such appliance is installed, used and maintained in accordance with the provided instructions.