FOOD WASTE DISPOSER use & care English ..............................................................
IMPORTANT SAFETY INFORMATION 3-BOLT MOUNTING SYSTEM Í NOTE This Food Waste Disposer has been designed to operate on 110-120V, 60 Hz exclusively. Using any other voltage or Hz adversely affects performance. IMPORTANT Read all instructions thoroughly. Keep this guide for future reference. INSTRUCTIONS PERTAINING TO A RISK OF FIRE, ELECTRIC SHOCK OR INJURY TO PERSONS. SAVE THESE INSTRUCTIONS.
REMOVAL OF OLD UNIT 1. REMOVAL OF OLD UNIT TYPICAL INSTRUCTIONS, YOUR MODEL MAY VARY. Before starting this step, turn off electrical power at the circuit breaker or fuse box. Unplug disposer. D. To remove remaining mount system from the sink, loosen mount screws, push mount ring up. Under it is the retainer ring. Use screwdriver to pop off ring (see 1D). Remove mount ring, protector ring and gasket from sink flange. Some mounts will require the unscrewing of a large ring holding the sink flange in place.
INSTALLATION 2. INSTALLATION OF MOUNTING ASSEMBLY A STOPPER B REMOVABLE SPLASH GUARD C SINK FLANGE D FIBER GASKET E SUPPORT FLANGE F UPPER MOUNT RING G MOUNT SCREWS H RETAINER RING I CUSHION RING J LOWER MOUNT RING* K SILVER GUARD® MAGNETIC CATCH RING** * Part not disengaged during disposer installation. **ATTACHMENT INCLUDED WITH MOST CONTINUOUS FEED 3/4 HP & 1-¼ HP MODELS. Installation instructions on last page.
INSTALLATION (CONTINUED) A. The Cushion Ring and the Lower Mount Ring will remain attached to the disposer during installation. Take apart the other parts of the mounting assembly by rotating the Lower Mount Ring clockwise until the Lower Mount Ring Tabs slide off from the Upper Mount Ring ramp (see A1). This allows you to pull the Sink Flange up and out of the remaining Lower Mount Assembly. Note the order of these parts as they are arranged in the required order.
INSTALLATION (CONTINUED) E. Take the remaining portion of the mount assembly that was put aside. From under the sink insert the Fiber Gasket (see E1), then the Support Flange (see E2), and then the Upper Mount Ring (see E3). F. Hold the three parts in place while attaching the Retainer Ring (see F1) by pulling it apart and having it snap within the groove of the sink flange (see F2). G. Tighten the three Mount Screws evenly and firmly against the Support Flange (see G1). Do not over tighten. H.
CONNECTION 7 3. DISHWASHER CONNECTION PREPARATION If you are utilizing a dishwasher, complete the following procedure. Using a blunt instrument (steel punch or wooden dowel), knock out entire plug. Do not use a screwdriver or sharp instrument. (When knockout plug falls into disposer, you may remove it or grind it up when the disposer is used. This will not damage the disposer in any way, but it may take some time to grind).
CONNECTION (CONTINUED) & GROUNDING INSTRUCTIONS B. Connect dishwasher hose (see 5C) using hose clamp. Make sure all plumbing connections are tight and in accordance with all plumbing codes and ordinances. Run water and check for leaks. Grounding Instructions FOR WASTE DISPOSERS EQUIPPED WITH A GROUNDED PLUG-IN POWER CORD. B. This appliance must be grounded.
GROUNDING INSTRUCTIONS (CONTINUED) 1. Turn off or disconnect all power to the wall junction box serving the disposer. 2. Open the junction box in the wall and remove the wire nuts or electrical tape or whatever is tying the old disposer wire to the electrical wire inside of the junction box. 3. If you are using nonmetallic-sheathed (ROMEX) cable: 1. Install cable fitting in the end bell hole and secure the cable to the fitting. 2.
PERMANENT WIRE INSTALLATION 1 1. After turning off power supply, unbolt two nuts and remove end plate. 2 2. Using a flathead screwdriver or needle nose pliers, remove clip from strain relief portion of the cord. 3 3. Using wire cutters, cut black (or brown) wire and white (or blue) wire near the connectors. 4 5 6 4. Pull cord strain relief out of endbell. Cut green ground wire near the cord strain relief. 5.
OPERATION 7. OPERATING INSTRUCTIONS Your disposer is Continuous Feed if you did not specifically purchase a Batch Feed Disposer. CONTINUOUS FEED 11 C. Insert stopper to start disposer (see B). One of the two small slots in stopper base must line up with switch plunger inside the neck of the disposer. Push down firmly to turn the disposer on. Lift stopper to shut the disposer off. The Anti-Jam Swivel Impellers make a clicking sound as they initially swing into place. This indicates normal operation. A.
CLEANING AND MAINTENANCE DO NOT ATTEMPT TO LUBRICATE YOUR DISPOSER! The motor is permanently lubricated. The disposer is self cleaning and scours its internal parts with each use. NEVER put lye or chemical drain cleaners into the disposer, as they cause serious corrosion of metal parts. If used, resulting damage can be easily detected and all warranties are void. Mineral deposits from your water can form on the stainless steel turntable, giving the appearance of rust.
TYPICAL INSTALLATIONS *Approximate Dimension 1/3 HP, 1/2 HP & 3/4 HP SlimLine Models 10.2 in 3/4 HP Deluxe 10.5 in 1-1/4 HP Premium 10.5 in Batch Feed units add approx. 2.1”/53mm For your specific disposer dimensions, contact Frigidaire customer service at 1-833-240-6224. MOUNTING THE SILVER GUARD® MAGNETIC CATCH RING After the disposer is fully mounted to the sink, guide the Magnetic Silver Guard® through the mount screws (6A) with the flat portion of the black strap facing the metal sink flange.
LIMITED LIFETIME WARRANTY AGAINST FAILURE DUE TO CORROSION Proof of purchase is required! Staple receipt or proof of purchase to this manual. Tracking is handled through the serial number affixed to the bottom of the disposer and/or on the power cord label. Conveniently record your model number and serial number on the front of this manual for your records. If you need warranty service, call us toll-free at 833-240-6224. Have serial number and receipt available for the technician.
welcome home Our home is your home.