PULSE915-LRW Terminal User Manual LoRaWAN Terminal Series Version 2.1 Date: 2020-09-11 www.friendcom.
PULSE915-LRW_User_Manual FCC Statement 1. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference. (2) This device must accept any interference received, including interference that may cause undesired operation. 2. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
PULSE915-LRW_User_Manual NOTICE Information in this document has been carefully reviewed and is considered to be accurate. However, Friendcom assumes no liability resulting from any inaccuracies or omissions in this document, or from use of the information obtained herein.
PULSE915-LRW_User_Manual Related Documents Friendcom_PULSE915-LRW_Terminal_Datasheet Friendcom_PULSE915-LRW_Configuration_User_Manual Conventions Symbol Indication This warning symbol means danger. You are in a situation that could cause fatal device damage or even bodily damage. Means reader be careful. In this situation, you might perform an action that could result in module or product damages. Means note or tips for readers to use the module.
PULSE915-LRW_User_Manual History Issue 1.0 1.1 1.2 2.0 2.
PULSE915-LRW_User_Manual Content About This Document........................................................................................................................................... 2 Table Index............................................................................................................................................................ 6 Figure Index.......................................................................................................................................
PULSE915-LRW_User_Manual Table Index Table 2- 1 Table 3- 1 Table 3- 2 Table 3- 3 Table 4- 1 Table 5- 1 Specifications of PULSE915-LRW............................................................................................... 9 Wiring definition of PULSE915-LRW...................................................................................... 11 Active pulse wiring...................................................................................................................
PULSE915-LRW_User_Manual Figure Index Figure 3- 1 Figure 5- 1 Figure 6- 1 Figure 6- 2 PCB wiring diagram.............................................................................................................. 11 Magnet activation position.................................................................................................. 19 Dimensions of PULSE915-LRW............................................................................................. 21 Installation of PULSE915-LRW.............
PULSE915-LRW_User_Manual 1 Introduction This document describes the technical parameters and key functions which are connected with customers’ applications, and it can help customers quickly understand the data format, wiring definitions, as well as other related information of PULSE915-LRW. Associated with configuration user manual, customers can use the terminal to any pulse emitting device (water, gas, electricity, etc.) easily. 2 Product Concept 2.
PULSE915-LRW_User_Manual Lifetime depends from the device location and reporting interval. 2.3 Specifications The following table describes the specifications of PULSE915-LRW Table 2- 1 Specifications of PULSE915-LRW Specifications Description Dimensions (L*W*H): 50 mm x 45.5±0.
PULSE915-LRW_User_Manual pulse signal input port supports single pulse and double pulse signal input. It supports both active and passive sensors. The sampling pulse time is less than 5ms, which can meet the requirement of typical water, electricity and gas instrument pulse acquisition. 2.
PULSE915-LRW_User_Manual Figure 3- 1 PCB wiring diagram The specific functions are defined as shown in the following table. Table 3- 1 NO. Name Wiring definition of PULSE915-LRW Function Wiring Remarks color Red 1 VOUT Power Output 3.
PULSE915-LRW_User_Manual 3.2.1 Active Pulse The ports that need to be used for active pulses are as follows: Table 3- 2 Active pulse wiring Port Single pulse Double pulse VOUT √ √ GND √ √ PUL-A √ √ √ PUL-B 3.2.2 Passive Pulse The ports that need to be used for passive pulses are as follows: Table 3- 3 Passive Pulse wiring Port Single pulse Double pulse GND √ √ PUL-A √ √ √ PUL-B 4 Data Format And Setting Command 4.
PULSE915-LRW_User_Manual Short data frame format: Name Frame header Byte Note 1 Fixed 0x56 Frame number and status 1 Bit 4- Bit 7: Frame number Bit 3: NC Bit 2: Magnetic interference flag, 0 means normal, 1 means abnormal. Bit 1: Broken line sign, 0 means normal, 1 means abnormal Bit 0: Low voltage alarm flag, 0 means normal, 1 means abnormal Address field 4 The device address, the factory default is the last 4 bytes of LoRaWAN module DevEUI, which can be modified by command.
PULSE915-LRW_User_Manual Checksum 1 Accumulate sum, the cumulative sum of one byte of data from the frame header to the check Terminator 1 Fixed 0x16 Take long data frame as an example 55 05 00 31 00 29 01 00 39 58 68 00 39 50 00 19 12 13 16 31 09 36 02 FD 16 Bytes Remarks 55 Frame header, fixed to 0x55 05 05 represents the 5th frame data sent by the module 00 31 00 29 It is the address of device, which is taken from the last four bits of DevEUI of LoRaWAN module 01 Reserved, fixed to 0x01 0
PULSE915-LRW_User_Manual AT+I Query the current electronic index, the unit is m³ AT+I=xxxxx.xxx Set the initial index, such as the current value of meter. Max. value is 5 integers and 3 decimal, the unit is m³. For example, to set the initial index is 55.123, the command is as follows: AT+I=55.123 Set InitValue = xxxxx.xxx Error AT+P Query pulse constant PulseConst = xxx Error Set PulseConst = 1000 Error AT+T RTC real-time clock query RTC real-time = year.month.
PULSE915-LRW_User_Manual hexadecimal digits. Example: AT+DA =ABCDEF01 AT+VP Read pull-up resistor configuration of external Vcc and two pulse sampling ports Vcc = **(ON), Pull Up = **(OFF) AT+VP=”vcc state”,”Pull up state” Set pull-up resistor of external Vcc and two pulse sampling ports. ON is open OFF is close Example: AT+VP=ON, OFF Set Vcc = ON, Pull Up = OFF AT+NP Read pulse type, support signal and double type.
PULSE915-LRW_User_Manual AT+DR=band Set the frequency band. For example, set the band to AU915. The command is: AT+DR=AU915. +DR: XXXXXX AT+CH=NUM, chm-chn Set channel. The transmit channel of the module must be consistent with the receive channel of the gateway. For example, set the channel to 0-7.
PULSE915-LRW_User_Manual Each pulse of 1 liter of water produces 1 pulse, that is, 1 m3 of water meter will produce 1000 pulses, then the pulse constant should be 1000 (if the pulse constant is reset, the initial reading must be reset). Parameter configuration can be manually entered through the serial port debugging assistant, or can be carried out using the PC software provided by Friendcom. 5 Parameters Configuration 5.
PULSE915-LRW_User_Manual 5.1.3 Entering Configuration Mode PULSE915-LRW terminal can be activated by magnet to enter configuration mode. Both the wired configuration mode and wireless configuration mode need to be activated before parameters configured. The reed switch inside the product is triggered by the magnet to put the product into the configuration mode, and then the configuration command must be sent within 30 seconds.
PULSE915-LRW_User_Manual 9s-15s >15s Reset Typically 12s No response Close magnet detecting function 60s When the product exits the configuration mode, basing on whether the user has sent a network access command (AT + JOIN) and whether the current mode is OTAA, it will automatically join the network if both are satisfied. The network access result can be verified by triggering whether the data report is successful.
PULSE915-LRW_User_Manual Figure 6- 1 Dimensions of PULSE915-LRW Page 21 / 23
PULSE915-LRW_User_Manual 6.2 Installation Figure 6- 2 Installation of PULSE915-LRW Installation method: 1) Ties installed in water pipes 2) Use screw to fixed it through side fixing holes 3) Mounted on DIN35 rails 4) Use screw to fixed it through front fixing holes 6.3 Transportantion and Storage Storage: -5C to 55C, non-corrosive gases. Less than 4 layers stacked and pay attention to shockproof during transportation.