Installation and Operation Manual PTAC Packaged Terminal Air Conditioners & Heat Pumps FreshAire TM
Table of Contents Congratulations········································································································································ 3 General Instructions·································································································································· 3 General Specifications·······························································································································4 PTAC Installation Recommendations···
Congratulations Thank you for your decision to purchase Friedrich. Your new Friedrich has been carefully engineered and manufactured to give you many years of dependable, efficient operation, maintaining a comfortable temperature and humidity level. Many extra features have been built into your unit to assure quiet operation, the greatest circulation of cool, dry air, and the most economic operation.
GeneralSpecifications Typical Unit Components and Dimensions WALL SLEEVE OUTDOOR GRILLE DISCHARGE GRILLE FILTERS PDXWS Wall Sleeve Dimensions: 16" H x 42" W x 13-¾" D Front Cover Dimensions: 16" H x 42" W x 7-¾" D Cut-Out Dimensions: 16-¼" x 42-¼" CHASSIS RETURN AIR GRILLE MODEL NUMBER FRONT COVER V H 09 3 F A Engineering Digit Series PV = Friedrich Digital PTAC Design Series System E = Cooling with electric heat H = Heat Pump with Auxiliary Heat Chassis F = FreshAire Nominal Capacity 07 = 7,
PTACInstallationRecommendations For proper PTAC unit performance and maximum operating life refer to the minimum installation clearances below: Figure 1 PTAC units should be installed no closer than 12" apart when two units are side by side. If three or more PTAC units are to operate next to one another allow a minimum of 36" between units. Also,a vertical clearance of 60" should be maintained between units installed.
Wall Sleeve Installation Instructions (PDXWSA) NOTE: Insure that the unit is only installed in a wall structurally adequate to support the unit including the sleeve, chassis and accessories.If the sleeve projects more than 8" into the room, a subbase or other means of support MUST be used. Please read these instructions completely before attempting installation. WARNING NOTICE Falling Object Hazard DO NOT allow any pitch toward the inside.
Alternate Wall Installations Figure 6 Figure 4 CurtainWall Panel Wall WALL OR WINDOW 1/4" MIN PROJECTIO N CASE FLANGE (BY OTHERS) OPTIONAL SUBBASE OPTIONAL SUBBASE LEVELING SCREW LEVELING SCREW FRP004 Figure 5 Figure 7 Frame and Brick Veneer Block and Brick Veneer 1/4" MIN PROJECTION 1/4" MIN PROJECTION CONCRETE LINTEL WOOD FRAME STEEL LINTEL STEEL LINTEL 13-3/4" MIN. WITHOUT SUBBASE 11" MIN.
Figure 8 Wall Sleeve Attachment ALTERNATE FASTENING METHODS (Field Supplied) WALL SLEEVE NOTE: The Wall Sleeve must be horizontally level (side-to-side) and pitched 1/4 bubble to the WOOD SCREW outside when installed in an opening. TOGGLE BOLT The mounting hole location EXPANSION should be approximately 2-4” ANCHOR BOLT from the top and bottom of the sleeve. MOUNTING HOLES PLASTIC ANCHORS SCREWS FRP008 Figure 9 Dimensions A ¼" MIN.
5. Drill two 3/16" holes through each side of the sleeve approximately 4" from top and 4" from bottom of sleeve. Screw four #10 x 1" screws (included) or appropriate fasteners for your installation, through the holes in the sides of the wall sleeve. 7. If the chassis and exterior grille are to be installed later, leave the weatherboard and center support in place, otherwise remove and dispose of them. (See Figure 13, Page 12). 8. 6.
PXDR10DrainKitInstallation Instructions (optional for new construction) NOTE: Determine whether drain will be located within the wall, on the indoor side, or will drain to the exterior of the building. Follow appropriate instructions below depending on your particular type of installation. Internal Drain NOTE: 1. 2. 3. Remove the backing from the gasket and mount it on the flat side of the mounting plate (See Figure 12, Page 11).
External Drain (for new construction or unit replacement) Cover Plate Installation When using an external drain system, the condensate is removed through either of two drain holes on the back of the wall sleeve. Select the drain hole which best meets your drainage situation and install the drain kit. Seal off the other with a cover plate. Peel the backing tape off the gaskets and apply the sticky side to one cover plate and one mounting plate as shown in Details A and B. 2.
PXGAStandard Grille Installation Instructions 5. Insert the remaining screws into the remaining holes and tighten securely. WARNING 1. Remove the center support and weatherboard if still installed in the sleeve. 2. Insert six plastic grommets into the grille openings from the outside of the grille as shown in Figure 13. Falling Object Hazard 3. Insert two #8 x ⅜" sheet metal screws (provided) in the top two outside edge plastic grommets, and tighten them half way into the grommets.
A. Electrical Rating Tables All units are equipped with standard power cords. NOTE: 1.5kW heater only for 12K Btu unit and 2.5kW heater only for 9K Btu unit. Table 1 Receptacles and Fuse Types 230V Voltage Amps Heater Size 15 20 1.5/2.5kw 3.5kw 30 5kw 15 265V 20 30 1.5/2.5kw 3.
TABLE 2 MODEL PVH09K PVH12K PVH09R PVH12R HEATER kW Power Cord Kit Voltage Amperage Receptacle 2.5(optional) STD 230/208 15 NEMA 6-15r 3.5(default) STD 230/208 20 NEMA 6-20r 1.5(optional) STD 230/208 15 NEMA 6-15r 3.5(default) STD 230/208 20 NEMA 6-20r 5.0(optional) STD 230/208 30 NEMA 6-30r 2.5(optional) STD 265/277 15 NEMA 7-15r 3.5(default) STD 265/277 20 NEMA 7-20r 1.5(optional) STD 265/277 15 NEMA 7-15r 3.5(default) STD 265/277 20 NEMA 7-20r 5.
Figure 16 Figure 15 TO CHASSIS JUNCTION STRAIGHT CONNECTOR WALL CONNECTION 4.0 IN. JUNCTION BOX GROUND SCREW GROUND WIRE HARNESS EXPOSE WIRES (1.0 IN.) 18.0 IN. FRP016 TRIM HARNESS TO LENGTH Figure 17 LEADING SIDE FOR WIRE HARNESS INSERTION SPACER STRIP WIRE ENDS (0.5 IN.) TO WALL JUNCTION 4. 5. SPACER Route the cut ends of harness through the conduit connector assembly and flex conduit sleeve. Be sure to use the s upplied conduit bushing to prevent damage to the cord by the con duit.
Chassis Install Preparation Check to be sure the wall sleeve, extension (if used), grille, and drain kit are installed properly before chassis installation. 1. Remove the weatherboard and center support from the sleeve (if still in place). Be sure an outdoor grille is attached. NOTE: Figure 18 To avoid breaking the door or hinge pins, do not apply excessive force when installing.
CAUTION Figure 21 Unit Damage Hazard Removing Front Panel Failure to follow this caution may result in equipment damage or improper operation. 2 3. Carefully remove shipping tape from the front panel and power vent door. See Figure 20. Figure 20 Shipping Tape Location 1 4. FRP021 Remove front panel,see Figure 21. Pull out at the bottom to release it from the tabs (1). Then lift up (2).
Chassis Installation 1. Lift unit level and slide unit into wall sleeve until seal rests firmly against front of wall sleeve. 3. Place tabs over top rail.(1)Push inward at bottom until panel snaps into place(2). 4. Reinstall front panel.See Figure 23. CAUTION Figure 22 SecuringUnit Excessive Weight Hazard Use two or more people when installing your air conditioner. Failure to do so can result in back or other injury. NOTICE Copper refrigerant tubes are NOT handles.
Friedrich PTAC Digital Control and Unit Features The new Friedrich digital PTAC has state of the art features to improve guest comfort, indoor air quality and conserve energy. Through the use of specifically designed control software for the PTAC industry Friedrich has accomplished what other Manufacturer’s have only attempted – a quiet, dependable, affordable and easy to use PTAC. Below is a list of features and their benifit to the owner.
DIGITAL DEFROST THERMOSTAT The PV-Series uses a digital thermostat to accurately monitor the outdoor coil conditions to allow the heat pump to run whenever conditions are correct. Running the PTAC in heat pump mode saves energy and reduces operating costs. The digital thermostat allows maximization of heat pump run time.
Figure 25 Air Vent Control System Configuration Fresh Air Vent Control To operate the FreshAire module please see Dip switch #3. With dip switch in the "on" position FreshAire module will be on continuously. With dip switch in the "OFF" position FreshAire module will be not be activated. POWER-DRIVEN VENT DOOR FRP025 Adjusting Air Figure 26 Toadjustair direction: 1. Removefrontpanel.SeeFigure21. 2. Remove louverscrewsthat holdlouver insertinplace(from back sideof frontpanel).See Figure 29. 3.
Digital Control User Input Configuration The adjustable control dip switches are located at the front portion of the digital Smart Center. The inputs are only visible and accessible with the front cover removed from the PTAC. Dip Switch Setting With the room freeze protection enable.Room Freeze Protection can be switched off at the owner’s preference by moving Dip Switch 5 to “OFF”.
FreshAire System SW3 DIP SWITCH Engagement Method Mode SW3-1 ON / OFF Description Fresh-Air Fan runs only when Dip Switch is set to ‘ON’ ON/CON. 1 2 OFF/CYC.
Digital Control Operation Figure 29 Digital Control Panel FRP029 Emergency Heat Operation Cooling Mode Pressing the “Cool” button after turn the unit on will put the unit into cooling mode. Press “UP” or “DOWN” button to adjust the set point, the unit will start the compressor and run appropriate frequency to maintain a comfortable room temperature. The compressor will come on anytime that the room temperature is 2℉above the set point. The fan will come on with compressor.
Settings- Detailed Configurations This section is about how to set the unit operating parameter, include display temperature unit, Fahrenheit or Celsius, control master, temperature limit, temperature calibration, display set point or room temperature. Under OFF mode, hold [Cool] and [Low] two keys at the same time continuously for 5 seconds. This time displays ‘d0’, indicates that system has entered the senior operation status.
Remote Control Thermostat Installation To control the unit with a wall mounted thermostat follow the steps below: Install Thermostat 1. Approximately 5 ft from the floor. 2. Close to or in a frequently used room,preferably on an inside wall. 3. On a section of wall without pipes or ductwork. The Thermostat should NOT be mounted: 1. Unplug the unit before doing any work 2. Remove the low voltage terminal block from the unit. 3.
Front Desk Control Terminal (ONLY FOR UNIT CONTROL) WARNING The Friedrich PV model PTAC has built-in provisions for connection to an external switch to control power to the unit. The switch can be a central desk control system. For front desk control operation, connect one side of the normal open switch to the R terminal and the other to the FD terminal. Electrical Shock Hazard Turn off electrical power before service or installation.
Final Inspection & Start-up Checklist Secure components and accessories, such as the chassis, decorative front cover and control door. Inspect and ensure that all components and accessories have been installed properly and that they have not been damaged during the installation process. Start the unit and check for proper operation of all components in each mode of operation.Instruct the owner or operator of this units operation, and the manufacturer’s recommended routine maintenance schedule.
Basic Troubleshooting Malfunction Possible Reasons S olution power line bad, units don’t have power supply. Check the indicator LED on the LCID power head, it should be lit up, if not, push the RESET button, if still don’t have voltage, but power grid has output, you need to change the power cord. Power cord protection trip. Check the power cord if somewhere is broken, push the RESET button. If not solved, replace the power cord. Power cord isn’t fixed well.
Malfunction Outlet temperature is not always cooling/heating Possible Reasons Solution When outdoor ambient temp is low, the heat Outlet temperature is not high enough when pump will not be able to offer enough heat. Soon heating by heat pump. after that, the E-heater will come on to heat. Fan stops when cooling/heating. It is normal when the CONSTANT FAN is OFF. Youcan enable the CONSTANT FAN. Outdoor is dripping water Not install the drain pipe kit. Install the drain pipe kit.
Service & Assistance Before calling for service, please check the "Basic Troubleshooting" section above.This may help you to find the answer to your problem, avoid unnecessary service calls, and save you the cost of a service call if the problem is not due to the product itself.
Accessories New Construction Accessories PDXWSA PDXWSEXT18 PDXWSEXT24 PDXWSEXT WALL SLEEVE Galvanized zinc coated steel is prepared in an 11step process, then powder coated with a polyester finish and cured in an oven for exceptional durability. The wall sleeve is insulated for sound absorption and thermal efficiency, 16" H x 42" W x 13 3/4" D. PDXWSA DEEP WALL SLEEVE For walls up to 17 1/2" D. DEEP WALL SLEEVE For walls up to 23 1/2" D.
New Construction Accessories PXFTB REPLACEMENT FILTER PACK These are original equipment return air filters. They are reusable and can be cleaned by vacuuming, washing, or blowing out, and are sold in convenient ten-packs. (Two filters per chassis). PXSBA DECORATIVE SUBBASE Provides unit support for walls less than six inches thick. Includes leveling legs, side filler panels and mounting brackets for electrical accessories. Accepts circuit breaker, power disconnect switch, or conduit kit.
Friedrich Air Conditioning Co. 10001 Reunion Place, San Antonio, TX 78216 800.541.6645 www.friedrich.com PV-SERIES PACKAGED TERMINAL AIR CONDITIONERS LIMITED WARRANTY SAVE THIS CERTIFICATE.It gives you specific rights.You may also have other rights which may vary from state to state and province to province. In the event that your unit needs servicing, contact your nearest authorized service center.