Product Overview

Installation
Installation of the Fire Department Connection is achieved with readily available
jobsite tools. Prior to installation make sure the proper identi cation sign has
been installed on the nipple. Coat male threads of 4” IPS nipple liberally with
a suitable pipe thread sealant such as PipeFit
®
. Tighten FDC one full turn past
hand tight. Make sure FDC is aligned according to requirements.
DO NOT OVER TIGHTEN. OVERTIGHTENING MAY CAUSE SEVERE
STRETCHING AND POSSIBLE CRACKING OF THE OF THE FDC BODY.
Specifi cations
Size:
4” IPS Outlet
(2) ” Inlets
Type:
Straight Pattern
Material:
B16 Brass*
Finishes:
Rough Brass
Polished Chrome**
Pin Lugs:
NST 3.0686 x 7½ T
BCT 3.0000 x 8 TP
CF 2.9900 x 7½ T
CIN-new 3.0580 x 6 TP
CIN-old 3.0930 x 6 TP
CLV 3.0780 x 8 TP
Dayton 3.2340 x 6 TP
DET 3.1250 x 7½ T
NovaSco 3.2300 x 5 TP
NYFD 3.0300 x 8 TP
ONT 3.1250 x 5 TP
PHX 3.0620 x 6 TP
QST 3.0310 x 7 TP
Raleigh 3.3400 x 6 TP
Richmon 3.3120 x 8 TP
TEM 3.0750 x 6 TP
Approvals:
UL Listed 300psi
FM Approved 300psi
*Contains lead. Not for use in
water systems intended for human
consumption.
**Polished chrome  nish only
available for NST pin lugs.
Description
The Straight Pattern Fire Department Connection is UL Listed and FM Approved.
Manufactured from solid brass* components to increase service life. The single
clapper design features brass clapper and brass seats within a cast brass body.
The 2½ ” inlets are pin lug design for ease of use and compatibility with local  re
service districts. Swivel gaskets are included. Breakable caps or plugs should be
installed to protect threads and prevent debris from being accidently introduced
into the water way.
WWW.FPPI.COM
Fire Department Connection
Single Clapper, Siamese Straight
The information above is believed to be reliable and accurate, but meant for reference only. FPPI and its agents cannot be
held responsible or liable for incidental or consequential damages or loss suffered by any person as a result of the use or
misuse of any of the information or its product by any person whose methods and quali cations are beyond our control. It is
the user’s responsibility to assure that products and methods of use are suitable for the intended purpose, and the preparation
prior to installation, and the installation is executed properly and according to existing code, regulations where applicable and
accepted industry practices. If you are not trained on the installation of this product, seek guidance from a quali ed installer.