Hardware Installation 5. Align the slots on the rear interposer square air duct with the posts on the cordite bracket. Position the air duct over the cordite module. Make sure the slots on the air duct are aligned with the standoffs in the module. 7. /RZHU WKH DLU GXFW WR LQVWDOO 7KH DLU GXFW PXVW EH ÀXVK ZLWK WKH FKDVVLV ZKHQ LQVWDOOHG SURSHUO\ )LJXUH ,QVWDOOLQJ D . & $% $LU 'XFW Replace the top cover on the server. See “Installing a Top Cover” on page 11.
Hardware Installation 3.11. Expander Assemblies 3.11.1. Expander Assembly Cable Routing CBL_R 45 Cable CBL_Cor i e an 4 Power Cable (Amphenol : R CBL_Slimline PC CBL_ C-AB B o Cor i e (Amphenol : RR 45-07 5) - 0 ) Cable (Amphenol : RSL74-33 5) ART Cable (Amphenol : R - 1 0) )LJXUH ([SDQGHU $VVHPEO\ &DEOH 5RXWLQJ 43
Hardware Installation 3.12. Expander Brackets 3.12.1. Removing a K2V4 Expander Bracket Follow these steps to remove an expander assembly: 1. Remove the top cover from the server. See “Removing a Top Cover” on page 10. 2. Disconnect the cables from the expander assembly. See “Expander Assembly Cable Routing” on page 43. 3. Remove the screws securing the expander assembly. 4. Disconnect the expander assembly from the mainboard. )LJXUH 5HPRYLQJ DQ ([SDQGHU $VVHPEO\ 44
Hardware Installation 3.12.2. Installing a K2V4 Expander Bracket Follow these steps to install an expander assembly: 1. Align the connector on the expander assembly with the connector on the mainboard. 2. Install the expander assembly. Press down gently to seat in place. 3. Secure the expander assembly with screws. )LJXUH ,QVWDOOLQJ DQ ([SDQGHU $VVHPEO\ 4. Connect the cables to the expander assembly. See “Expander Assembly Cable Routing” on page 43. 5. Replace the top cover on the server.
Hardware Installation 3.13. K2C-AB 3.13.1. Removing a K2C-AB Follow these steps to remove a K2C-AB: 1. Remove the top cover from the server. See “Removing a Top Cover” on page 10. 2. Remove the interposer assembly. See “Removing an Interposer Assembly” on page 39. 3. Disconnect the cables from the interposer assembly. 4. Remove the screw securing the K2C-AB. 5. Disconnect the K2C-AB from the interposer board Remove the K2C-AB. )LJXUH 5HPRYLQJ D .
Hardware Installation 3.13.2. Installing a K2C-AB Follow these steps to install a K2C-AB: 1. Align the connector on K2C-AB with the connector on the interposer board. 2. Connect the K2C-AB to the interposer board. 3. Secure the K2C-AB to the interposer bracket with the screw. )LJXUH ,QVWDOOLQJ D . & $% 4. Connect the cables to the interposer assembly. 5. Install the interposer assembly. See “Installing an Interposer Assembly” on page 41. Replace the top cover on the server.
Hardware Installation 3.14. K2V4 3.14.1. Removing a K2V4 Card Follow these steps to remove an expander card: 1. Remove the top cover from the server. See “Removing a Top Cover” on page 10. 2. Remove the expander assembly. See “Removing a K2V4 Expander Bracket” on page 44. 3. Disconnect the SATA cable and UART cable from card. See “Expander Assembly Cable Routing” on page 43. 4. Turn the expander assembly over to gain access to the card. 5.
Hardware Installation 3.14.2. Installing a K2V4 Card Follow these steps to install an expander card: 1. 5HPRYH WKH GXPP\ EUDFNHW IURP WKH EXWWHUÀ\ EUDFNHW )LJXUH 5HPRYLQJ D 'XPP\ %UDFNHW 2. Align the connector on card with the connector on the riser board. 3. Insert the expansion card in the riser board. )LJXUH ,QVWDOOLQJ D . 9 &DUG 4. Once correctly seated, lock the expansion card in the bracket by rotating the locking lever to the closed position. 5.
Hardware Installation 3.15. NVMe SSD 3.15.1. Removing an NVMe SSD 1. 2. 3. 4. 5. Follow these steps to remove an NVMe SSD: Remove the top cover from the server. See “Removing a Top Cover” on page 10. Remove the interposer assembly. See “Removing an Interposer Assembly” on page 39. Remove the K2C-AB. See “Removing a K2C-AB” on page 46. Remove the screw securing the NVMe SSD assembly. Slide the NVMe SSD assembly to unlock from the posts and remove. )LJXUH 5HPRYLQJ DQ 190H 66' $VVHPEO\ 3XOO WKH EUD
Hardware Installation 7. Remove the NVMe SSD. )LJXUH 5HPRYLQJ DQ 190H 66' 3.15.2. Installing an NVMe SSD Follow these steps to install an NVMe SSD: 1. 3XOO WKH EUDFNHW RXW DQG DOLJQ WKH KROHV RQ WKH 190H 66' ZLWK WKH ¿[HG EUDFNHW RQ WKH 66' bracket. ,I WKH 66' LV SURSHUO\ LQVHUWHG LQ SODFH WKH ¿[HG EUDFNHWV ORFN WKH 66' PRGXOHV LQ WKH FDJH )LJXUH ,QVWDOOLQJ DQ 190H 66' 51
Hardware Installation 2. Align the NVMe SSD assembly with the posts in the server. 3. Slide the NVMe assembly until the connectors are fully engaged. Make sure the posts on the cage have locked onto the bottom of the SSD carrier. 4. Secure the NVMe SSD assembly with the screw. )LJXUH ,QVWDOOLQJ DQ 190H 66' $VVHPEO\ 5. Install the K2C-AB. See “Installing a K2C-AB” on page 47. Install the interposer assembly. See “Installing an Interposer Assembly” on page 41. 7.
Hardware Installation 3.16. Interposer Boards 3.16.1. Removing an Interposer Boards Follow these steps to remove an interposer board: 1. Remove the top cover from the server. See “Removing a Top Cover” on page 10. 2. Remove the interposer assembly. See “Removing an Interposer Assembly” on page 39. 3. Remove the K2C-AB. See “Removing a K2C-AB” on page 46. 4. Remove the NVMe SSD. See “Removing an NVMe SSD” on page 50. 5. Remove the screws securing the interposer board.
Hardware Installation 3.16.2. Installing an Interposer Board Follow these steps to install an interposer board: 1. Align the holes on the interposer board with the standoffs on the interposer bracket. 2. Secure the interposer board with the screws. )LJXUH ,QVWDOOLQJ DQ ,QWHUSRVHU %RDUG 3. Install the NVMe SSD. See “Installing an NVMe SSD” on page 51. 4. Install the K2C-AB. See “Installing a K2C-AB” on page 47. 5. Install the interposer assembly. See “Installing an Interposer Assembly” on page 41.