SKYWELL User Manual Atmospheric Water Cooler Model: Spec: Serial Number: Admin PIN: Date of Purchase: Please register this unit at Skywell.com to activate warranty and get the latest product updates. SAVE THIS MANUAL FOR FUTURE USE When using electrical appliances, basic safety precautions should be followed in order to reduce the risk of fire, electric shock and injury to persons or property.
To reduce risk of injury and property damage, please read this entire manual before assembling, installing & operating the dispenser. Failure to execute the instructions in this manual could cause personal injury or property damage. QUICK SETUP AND INSTALLATION . Excessive Weight Hazard. Use two or more people to move and install the water cooler. 1 Find the perfect spot for your Skywell on a hard level surface. It should have 4 inches of space in each direction to ensure proper air flow and operation.
WELCOME TO YOUR SKYWELL Congratulations on your selection of an advanced state-of-the-art Atmospheric Water Generator, water cooler, and multi-purpose dehumidification unit. Your Skywell 5T1.5 uses a fan to draw moist air into the machine, where it passes through a chilled evaporator coil that cools the air to below the dew point.
SAFETY PRECAUTIONS Ensure you read this entire manual before operating the machine for the first time. This product dispenses water at very high temperatures. Failure to use properly can cause personal injury. When operating this dispenser, always exercise basic safety precautions, including the following: 1. Prior to use, this dispenser must be properly assembled and installed in accordance with this manual. 2. This dispenser is intended for water dispensing only. Do NOT use other liquids.
PRODUCT SPECIFICATIONS Power rating Refrigerant Types Cold Water Power Cold water capacity / Hour Hot Water Power Hot water capacity / Hour Dispense Temp. Range Collection tank capacity Cold tank capacity Hot tank capacity Dimensions Net Weight AC120V / 60Hz / 13A R-134a & R-410a 70W 0.8L / 0.21Gallons 850W 7.2L / 1.9Gallons 39°F - 203°F 6 L / 1.6 Gallons 10 L / 2.5 Gallons 0.8 L / 0.21 Gallons 123.6 H × 32 W × 50.2 D (cm) 48.7 H × 12.6 W × 19.
WATER FILTER BREAK-IN PRIOR TO USE (OPTIONAL) While the very first drops of Skywell water will be clean, fresh water, the first few gallons may have a less than optimal taste while the filters break in. In order to avoid this Skywell recommends that the first 10 gallons produced not be consumed. (Feel free to water plants or otherwise use the water as you see fit.
Custom Logo SETTING PRODUCTION SCHEDULE To set up a custom schedule for producing water, first go to the Settings Menu. In the lower-right-hand corner there are two options: Schedule Daily Generation – use to set regular production schedule. You can set up to 4 different time periods and have each produce water at different rates. “MAX” will produce the most water but also have the most “fan noise.
CLEANING AND CARE Disinfecting the dispensing point Time Required: 5 minutes Recommended Frequency: Once per month The Skywell machine is self-cleaning internally, but the dispensing point for the water interacts with the outside environment. Regular use of the hot water will generally disinfect the dispensing point, but extra care at the dispensing point can ensure you always have the cleanest water possible.
Replacing water filters Time Required: 15 minutes Recommended Frequency: Quarterly NOTE: If you purchased a service plan through Skywell, a certified technician will perform all replacements of filters for your machine. 1) Unplug your Skywell and wait for any noises to cease. 2) Open the front cabinet door to expose the filter manifold. 3) Place a bowl or other device below the filters to catch any water that may drip out as a result of releasing filters.
IMPORTANT: Do NOT Return Dispenser To Store. If you have a question or problem, please contact 1-844-SKY-WELL for assistance. TROUBLESHOOTING TIPS PROBLEM No hot water No cold water POSSIBLE CAUSES HOW TO SOLVE 1. There is no power to the outlet, machine 1. Ensure that the power outlet has power by testing another safe device. is not plugged in, or power switch is off 2. Allow machine to generate additional water, 2.
Water leaking from unit 1. Collection tank lid is not aligned correctly. 2. Filters not seated correctly in filter manifold. 3. Water line cracked. 4. Level sensors are out of the tank. 1. Ensure that the lid to the collection tank is perfectly covering it and is firmly in place. 2. Remove water filters and put back in place, ensuring tight fit (see page 9) 3. Open cabinet door at front of unit and see if you can find a drip. Replace line if possible or call for service.
IMPORTANT: Do NOT Return Dispenser To Store. If you have a question or problem, please contact 1-844-SKY-WELL for assistance.
QUICK REFERENCE GUIDE Cleaning the air filter 1. 2. 3. 4. 1 2 3 Open the air filter door Remove the air filter Rinse until clean Return air filter and close filter door Changing the water filters NOTE: Use only Skywell water filters. Other filters may damage the unit and will void the warranty. 1) Unplug your Skywell and open the front cabinet door 2) Place a bowl or drip tray below filters 3) From left to right, replace the filters one at a time: 1.
—Reorient or relocate the receiving antenna. —Increase the separation between the equipment and receiver. —Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. —Consult the dealer or an experienced radio/TV technician for help. FCC Radiation Exposure Statement This device complies with FCC radiation exposure limits set forth for an uncontrolled environment and it also complies with Part 15 of the FCC RF Rules.