Manual

Parts List
C.SCH−2* & C.SCT−2
Foot Control, 230V
FOREDOM The Foredom Electric Company
16 Stony Hill Rd., Bethel, CT 06801 203−792−8622
Fax: 203−796−7861
www.foredom.net
}
Wiring Diagram
*C.SCH−2 is required for use with the latest
SR 230V Motors produced since May 2006.
Form DN 1/11
Qty
DescriptionPart No.Item
1
CoverCP10691
1
1
Trigger Switch, 250VCP11027
2
2
Screw, 6−32 x 5/16"CP10571
3
1
Bracket
CP11030
4
1
Base
CP10690
5
1
Base Pad
CP10753
6
1
Male Cordset or Substitute OptionCP10541
7
2
Hinge Pin
CP10584C
8
1
GrommetCP10578
9
1
Terminal Ring
CP10580
10
1
Lock Washer, #8
CP10564
11
1
Screw, 8−32 x 1/4"CP10563
12
1
Wire ConnectorCP11029
13
1
Female Cordset (SCT−2)
Female Cordset (SCH−2)
CP10542
CP10868
14
1
Set ScrewCP10562
15
1
SpringCP10588
16
Bracket
Tigger Switch
CP11027
AC Male Plug
To Power Source
Attach Ground
Screw to Base
Female Receptacle
to Motor
BRN (BLK)
GRN/YLW (GRN)
BLU (WHT)
WHT (BLU)
BLK (BRN)
GRN (GRN/YLW)
CPOption20 CP10545 No Plug, Europe
CPOption21 CP10553 Male, United Kingdom
CPOption22 CP10554 Male, Continental Europe
CPOption25 CP10555 Male India 10A
CPOption26 CP10556 Male, Austrailia
Cordset Option
Part No.
Description
5
6
1
4
3
2
Connect Wires to New Trigger Switch as shown in the
Wiring Diagram.
Push wires all the way in, so that no bare wire
is exposed. On Screw Terminal 1, push the wire lead all the way
into the socket then tighten the screw firmly. Push the other
wire lead all the way into terminal 6. Pull on all the wires, making
sure they are secure.
On older Switches, all the terminals will be push-in, spring clamp
type. On newer Switches, Terminal 1 has a screw for fastening
the wire lead. To remove wires from the push-in terminals, insert
1.3mm [.05in] approximate diameter pin or the blade of a jeweler's
screwdriver all the way into the terminal socket to release the spring
clamp. Grasp the tool and wire and pull them together out of the
socket. If you have difficulty removing the wires from the push-in
terminals and you have wire-cutting, stripping, and soldering tools,
you can cut the wires off where they exit from the terminals. To
prepare the cut wires for installation into the replacement Switch,
strip them back exactly 8.25 mm [5/16 in], then apply solder to the
stripped ends to fuse the strands together.
Insert new Trigger Switch into Bracket.
6.
5.
Position wires around post of Base so wires will not
interfere with Cover travel.
8.
Install Cover over Spring (16) and align holes to Base.
Insert Pins (8) and seat them with hammer.
9.
Install Bracket and Switch into Base using two Screws (3).
7.
1.
2.
Remove two Screws (3) from Bracket (4). After the wires have
been removed from the switch, as instructed in paragraph 4,
remove the switch from the board, insert the new switch in its
place, and follow the instructions in paragraph 5 and 6.
Remove Cover and drive Pins outward with hammer and punch
to remove.
With a punch and hammer drive two Pins (8) in until Cover (1)
lifts from each side of Base (5).
Disconnect Foot Control from Motor and Wall Outlet.
Instructions for Removing
and Replacing Trigger Switch
3.
4.
1
3
4
5
6
7
8
9
11
10
15
16
12
7
2
13
Wire
Connector

Summary of content (1 pages)