目录 0.0 Versions and updates .......................................................................................................................................................... 4 1.0 Overview .................................................................................................................................................................................... 4 2.0 Pay attention to safety matters ...............................................................................................
10.1.8 Settings menu->General->Bluetooth switch ........................................................................................... 26 10.1.9 Settings menu->General->Gravity direction recognition ................................................................... 26 10.1.10 Settings menu->General->Boot page ...................................................................................................... 27 10.1.11 Settings menu->General->reset ...................................................
0.0 version and updates As the instrument has many functions and frequent software and hardware updates, the manual may be updated at any time, please be aware. Please get the latest update information on the official website. 1.0 Overiew The C1 TYPE-C tester is a high-reliability, high-safety USB voltage and current detection meter and a mobile communication terminal fast charging trigger. It has a 1.3-inch TFT LCD display with 240x240 ultra-high pixels.
4 When working with high power, the temperature of the instrument rises, please be careful to prevent burns; 5 Please do not charge the phone after the fast charge is triggered. Therefore, the manufacturer is not responsible for damage to the phone. 3.0 Performance description 3.0.1 Interface 1 Input monitoring port: TYPE-C, 24-PIN male; 2 Output monitoring port: TYPE-C, 24-PIN female socket; 3 PC connection port: Micro-USB, 5-PIN female socket. 3.0.2 Human-computer interaction 1 1.
4 1 set of voltage and current curve records, maximum support 9 hours; 5 Support low-speed waveform (voltage, current, D+, D-) drawing, 2sps --> 100sps sampling rate; 6 Support high-speed ripple (voltage, AC coupling) drawing, 5Ksps --> 4Msps sampling rate. 3.0.4 Fast charge trigger 1 QC2.0, QC3.0 trigger; 2 Huawei FCP, SCP trigger; 3 Samsung AFC trigger; 4 PD2.0/3.
2 Onboard temperature measurement; 3 Gravity sensor, automatically switch the display direction, the whole interface supports 4 direction switching; 4 PD monitoring; 5 Apple 2.4A acceleration; 4.
5.0 Technical Specifications Accuracy: ±(a%(‰) reading + number of words) Index Range Resolution Accuracy Monitorvoltage 4~24V 0.00001V ±(0.2‰+2) Monitorcurrent 0~6.5A 0.00001A ±(0.5‰+2) Monitor power 0~130W 0.00001W ±(0.5‰+2) 0~9999.9Ω 0.0001Ω ±(0.5‰+2) D+/D- voltage 0~3.3V 0.001V ±(1.0%+2) Equipment ℃ 1℃ ±(1.2%+3) temperature ℉ 1℉ ±(1.2%+4) capacity 0~9999.99Ah 0.00001Ah energy used 0~9999.99Wh 0.00001Wh 0~9999.9Ω 0.
6.0 Main Page Except for special instructions, left and right buttons switch pages/menus, OK button and click to confirm, OK button and long press to cancel/return. 6.0.1 Concise Page Description Only 4 key parameters of voltage, current, power and load equivalent internal resistance are displayed, → indicates the direction of current. This page can change the display direction. Instructions (1) Long press the left button: enter the setting menu. (2) Click the OK button: switch to 6-bit resolution.
(3) Long press the OK button: when the setting menu -> general -> gravity direction recognition is off, switch the screen direction. 6.0.
curve. The color display indicates that it is recording, and the gray color indicates that it is not recording. Instructions (1) Long press the left button: switch to the capacity/power consumption list (please see the following instructions). (2) Click the OK button: start/stop the voltage and current curve recording. It cannot be started when the recording time is 0. (3) Long press the OK button: prompt to restart the calculation of the minimum, maximum, and average values of voltage, current, and power.
The top row of data from left to right is the boot record time and the onboard temperature respectively; The uppercase data on the left is voltage, current, and power from top to bottom; From top to bottom on the right are: 1. The trigger time limit is the setting menu->trigger->trigger time value. 2. The percentage of remaining trigger time. 3. Trigger status. 4. Trigger type The trigger timing is the timing of the trigger time.
6.0.4 Curve display page Description Mode 1: Low-speed voltage and current curve (2sps -> 100sps) Mode 2: Low-speed D+D-curve (2sps -> 100sps) Mode 3: High-speed voltage ripple (AC coupling) (5Ksps -> 4Msps) The following picture shows the sine wave, square wave and triangle wave at 200KHz.
Instructions (1) Long press the left button: time base subtraction. (2) Click the OK button: start/pause drawing the curve. (Except in mode 3, it will prompt whether to clear the curve). (3) Long press OK key: switch mode. (4) Long press the right button: time base plus. 7.0 Expansion of recording function 7.0.1 Energy Statistics List Description In the record page (6.0.2) long press the left button to enter.
7.0.2 Offline curve observation page Description Click OK to prompt to clear the record curve. 8.0 Quick charge protocol trigger and detection menu Description On the (6.0.3) fast charge recognition page, long press the left button and confirm to enter.
This meter supports QC2.0/QC3.0, HuaWei FCP/SCP, Samsung AFC trigger, PD2.0/3.0 trigger. caveat Once you have entered the quick charge trigger/detection interface, all operations must be performed carefully, and it is forbidden to connect to equipment that cannot withstand high voltage. During the use of this function, the author will not be responsible for the loss caused by misoperation. 8.0.
8.0.2 QC2.0 trigger In QC2.0 trigger mode, use the left and right keys to select the trigger voltage, and long press the OK key to return. 8.0.3 QC3.0 trigger In QC3.0 trigger mode, use the left and right keys to decrease/increase the trigger voltage, and long press the OK key to return. Press the left/right keys to quickly decrease/increase the voltage.
8.0.4 Huawei FCP trigger The operation mode is the same as QC2.0 trigger. 8.0.5 Huawei SCP trigger The operation mode is the same as QC3.0 trigger.
8.0.6 Samsung AFC Trigger The operation mode is the same as QC2.0 trigger. 8.0.7 PD protocol trigger Take the picture as an example. The picture shows a charger sending a message with a total of 6 gears, among which gears 1, 2, 3, 4, and 5 are fixed voltage gears, and gear 6 is adjustable voltage gear (PPS).
and right keys. When the gear is switched to the PPS gear, you can switch the step voltage by clicking the middle button. After selecting the step voltage, press the left and right keys (left Decrease right plus), decrease/increase the voltage. 9.0 Charging tool On the (6.0.3) fast charge recognition page, long-press the right button to enter the charging tool menu. The functions are: 1 PD listener. 2 Read the E-Marker cable. 3 wire resistance measurement. 4 Apple 2.4A acceleration. 9.0.
In the figure above, the charger is a 105W PD charging head. The current PD consumer selects the 5th gear and triggers the target voltage of 20V,the maximum current is 5A. Click the middle button to switch to the "View Detailed Communication Process" page, as shown in the figure above. In the left column, you can select the message to be viewed by the left/key, such as: Now select the message with 0x1882 REQ <-. It is the message number.
head for the gear required for charging (for example, 6 gears in this example, request one of the gears) ). <- Indicates the direction of data transmission, which means that this message is sent to the PD charging head by the PD consumer. The right column 3304B12C (hexadecimal) contains information such as voltage and current when sending a request message. In addition, in this interface, long press the left button to clear the data buffer. Long press the right button to quickly browse the messages.
read the message, as shown in the figure below. Click OK to switch to the figure below. The above two pictures, one picture is the parsed data, and the second picture is the original data. Users can consult the PD protocol related materials and make comparisons by themselves.
9.0.3 Wire resistance measurement page Description C1 uses the differential pressure method to measure the internal resistance of the cable, which needs to be used with a constant current load. Instructions Click the OK button: use the current voltage and current value as the reference value. Measurement procedure (1) Connection method: charger + C1 + constant current load (the current is adjusted to about 0.5-1A), and record the reference value.
9.0.4 Apple 2.4A acceleration The Apple device can only charge at 5V-2.4A when it detects that the charging head D+ and D- are 2.7V. This function sets D+ and D- to 2.7V. 10.0 setting menu Description In the setting menu, left and right buttons can select menu options, click OK to enter/confirm the current options, long press OK to return/cancel/exit the current options/menu. 10.1 Settings menu -> General Set up some general system configurations. 10.1.
10.1.2 Settings menu->General->Standby brightness Set the brightness of the standby screen, the adjustable range is 0-20, when it is set to 0, the screen will be turned off directly after entering the standby state. 10.1.3 Settings menu->General->Standby time Set the standby time, the last time you operate the button to start timing, reach the standby time, enter the standby state. 10.1.4 Settings menu->General->Data transmission After closing, unable to connect to the computer through the PC port. 10.1.
by long pressing the OK button on the (6.0.1) concise page. 10.1.10 Settings menu->General->Startup page Turn on/off the boot page. 10.1.11 Settings menu->General->Restore factory settings Restore all settings except recorded data. 10.2 Settings menu -> record Set the configuration required for logging data. 10.2.1 Setting menu->Record->Curve record time Set the recording time of the voltage and current curve, the maximum is 9 hours, set to no time without recording.
10.3 Settings menu -> trigger Trigger related configuration. 10.3.1 Setting menu -> Trigger -> Trigger time Set the trigger time. 10.3.2 Setting menu -> Trigger -> Block PD CRC After it is enabled, CRC packets can be shielded when PD is monitoring, and it is disabled by default. 10.3.3 Settings menu -> Trigger -> Power on Apple 2.4A Settings menu -> Trigger -> Power on Apple 2.4A. 10.
device firmware version. 3 Click “System”, In the location of the file, import the firmware version you want to upgrade. 4 Click “Refresh icon”,START to start the firmware upgrade. After the upgrade is complete, the watch will automatically restart and enter the main interface. 12.
A: This is the reason for the agreement, which is normal. 4 Q: After the SCP or PD is released, if another protocol is triggered, it will restart? A: This is the reason for the agreement, which is normal. 5 Q: Enter the PD to monitor a black screen? A: Entering the PD monitor will turn off the CC pull-down, so it is recommended to use an external power supply.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.