User Manual Version 1.
Copyright 2013 All Rights Reserved Manual Version 1.0 The information contained in this document is subject to change without notice. We make no warranty of any kind with regard to this material, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. We shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material.
CE MARK This device complies with the requirements of the EEC directive 2004/108/EC with regard to “Electromagnetic compatibility” and 2006/95/EC “Low Voltage Directive” FCC This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference.
Safety Caution Note: To comply with IEC60950-1 Clause 2.5 (limited power sources, L.P.S) related legislation, peripherals shall be 4.7.3.2 "Materials for fire enclosure" compliant. 4.7.3.2 Materials for fire enclosures For MOVABLE EQUIPMENT having a total mass not exceeding 18kg.the material of a FIRE ENCLOSURE, in the thinnest significant wall thickness used, shall be of V-1 CLASS MATERIAL or shall pass the test of Clause A.2.
be readily identifiable and easily reached by the operator. For single-phase portable equipment, a plug on a cord of length not greater than 3m is considered to be easily reached. LEGISLATION AND WEEE SYMBOL 2012/19/EU Waste Electrical and Electronic Equipment Directive on the treatment, collection, recycling and disposal of electric and electronic devices and their components.
Revision History Revision Date V1.
Table of Contents 1 Intended Use ...................................................... 1 2 Package Checklist ............................................ 2 2-1 Standard Items ................................................................................. 2 3 System View ....................................................... 3 3-1 3-2 3-3 3-4 3-5 Front View .......................................................................................... 3 Side View............................................
1 Intended Use According to the Instructions for Use (IFU) of the manufacturer, the Bedside Terminal has the following intended use: The Bedside Terminal Hardware System is a computing device capable of storing, retrieving and sending data electronically. This Bedside Terminal Hardware System, including its user interface, battery, PCB and power supply, is intended to be fixed to a stand in medical care environment.
2 Package Checklist 2-1 Standard Items a. System b. Phone module c. Power adapter d. Power Cable e. Manual f.
3 System View 3-1 Front View Number Description 1 Build-in camera 2 Camera LED 3 Touch screen 4 Touch keys (from left to right: reading light, volume down, volume up, channel down, channel up , power button) 5 Smart IC card reader 6 VOIP phone (optional) 3
3-2 Side View Number 1 2 3-3 Description Combo smart IC card reader with separate RFID antenna (optional) Speaker Rear View Number Description 1 Light Sensor 2 Webcam switch 3 Ventilation 4 SSD/HDD door 5 Cable cover 6 Vertical I/O port (from left to right: Nurse call, Display port, DC jack, USBx2, LAN ) 4
3-4 Bottom View Number Description 1 Ventilation 2 From left to right: Video in, Audio left, Audio right (optional) 3 Bottom I/O port (from let to right: LAN, USBx2, Remote, Power button) 3-5 4 Microphone 5 Smart IC card reader 6 USBx1 7 Phone jack (RJ11) 8 From left to right: Audio line-out, Mic-in, Audio line-out Dimension 5
4 System Assembly 4-1 SSD/HDD Replacement 1. Remove the screw (x1) to open the HDD door. 2. Remove the screw (x1) that fixed the HDD to the system. 3. Pull the HDD outward as shown in the picture. 4. The HDD is secured by a metal bracket, remove the screws (x2) to release the metal bracket from the HDD.
5 Peripherals Installation 5-1 Phone module Installation 1. Loosen the screw(x1) to open the cable cover. 2. Slide the phone module into the phone holder and connect the other end of the phone cable to the connector on the system.
5-2 Stand Installation 2. Fasten the screws.
6 Specification Model K948 Motherboard C73 Processor Intel Celeron 1047UE Core Logic CPU with Graphic built-in HM76 System Memory 2 x DDR3 SO-DIMM slot up to 8GB FSB1600Mhz Graphic Memory DX11, HD Graphic 350MHz LAN Controller / PHY Intel WG82583V / Intel Audio Controller WG82579V Realtek ALC 662-GR HD codec I/O Controller Winbond W83627UHG Touch TF P-cap 18.5” Camera LED Green-color (GPIO) Microphone 1 Power LED Tri-color (GPIO) Watch Dog Timer Hardware WDT Display Size 18.
Model K948 Motherboard Mic-In C73 1 (Auto-detect,GPIO), in external IO Vertical I / O LAN 1 x RJ45 (with 10/100/1000) Power DC Jack 1 x DVI-D Display Port 1 x DVI-D USB 2 (USB 2 .
Manufactory information: Factory: Flytech Technology Co., Ltd. Address: NO.36 Huaya 3rd Rd., Guishan Township, Taoyuan County 33383, Taiwan Tel No: 886-3-272-9688 Fax No: 886-3-272-9666 Note: Cleaning solution-Wipe with cloth using clean water, 2 times a week. Adaptor Manufacturer: FSP TECHNOLOGY INC. 1. Model: PMP105-18-B15 Rating: 100-240V,47-63Hz,0.7 – 1.4A 2. Model: PMP60-12-B16 Rating: 100-240V,47-63Hz,1.22-0.
7 Jumper Setting 7-1 C73 Motherboard 12
7-2 Connectors & Functions Connector CN2 CN3 CN4 CN5 CN6 CN7 CN8 CN9 CN10 CN11 CN12 CN14 CN16 CN17 CN18 CN19 CN20 CN22 CN23 CN25 CN26 CN27 CN28 CN29 CN30 CN31 CN32 CN33 CN34 CN36 CN37 CN38 CN39 RJ45_1 USB1 SCSI 1 SW1 SW2 RJ45_2 DP1 PWR1 USB2 RJ48_1 USB3 RJ11_1 SATA0 SATA1 FAN_CPU1 Function Scanner Nurse Call LED Power Build-In MIC Inverter COM5 (for touch) USB port for Web Cam HDD LED SATA Power SATA Power PS/2 keyboard LVDS COM1 USB Power LED USB USB IrDA Reading Light Cradle USB USB First Audio Jack Sec
7-3 Jumper Setting Brightness Type Selection JP1 Function (1-2) (3-4) (5-6) ▲LED Power Mode Setting JP8 Function (1-2) ▲ATX Power AT Power LCD ID Setting JP5 Function (1-2) (3-4) (5-6) (7-8) 18.