TiS10, TiS20, TiS40, TiS45, TiS50, TiS55, TiS60, TiS65 Performance Series Thermal Imagers Users Manual July 2015 © 2015 Fluke Corporation. All rights reserved. Specifications are subject to change without notice. All product names are trademarks of their respective companies.
LIMITED WARRANTY AND LIMITATION OF LIABILITY Each Fluke product is warranted to be free from defects in material and workmanship under normal use and service. The warranty period is two years and begins on the date of shipment. Parts, product repairs, and services are warranted for 90 days.
Table of Contents Title Page Introduction .................................................................................................................... How to Contact Fluke .................................................................................................... Safety Information.......................................................................................................... Operation in Extreme Conditions .......................................................................
TiS10, TiS20, TiS40, TiS45, TiS50, TiS55, TiS60, TiS65 Users Manual IR-PhotoNotes™ ....................................................................................................... Voice Annotation (Recording) ................................................................................... Listen to a Voice Annotation (Recording) .................................................................. Edit Captured Infrared Image ...........................................................................
Contents (continued) Localization .......................................................................................................... Language ............................................................................................................. Wireless Connectivity ........................................................................................... Image Storage......................................................................................................
TiS10, TiS20, TiS40, TiS45, TiS50, TiS55, TiS60, TiS65 Users Manual iv
List of Tables Table 1. 2. 3. 4. 5. Title Page Symbols ................................................................................................................................ Accessories .......................................................................................................................... Features and Controls .......................................................................................................... Palettes ...................................................
TiS10, TiS20, TiS40, TiS45, TiS50, TiS55, TiS60, TiS65 Users Manual vi
List of Figures Figure 1. 2. Title Page Laser Warning ...................................................................................................................... 2 Level and Span Settings .......................................................................................................
TiS10, TiS20, TiS40, TiS45, TiS50, TiS55, TiS60, TiS65 Users Manual viii
Introduction The Fluke TiS10, TiS20, TiS40, TiS45, TiS50, TiS55, TiS60, and TiS65 Thermal Imagers (the Product or Imager) are handheld, infrared imaging cameras for use in multiple applications. These applications include equipment troubleshooting, preventive and predictive maintenance, building diagnostics, and research and development.
TiS10, TiS20, TiS40, TiS45, TiS50, TiS55, TiS60, TiS65 Users Manual How to Contact Fluke Safety Information To contact Fluke, call one of the following telephone numbers: A Warning identifies conditions and procedures that are dangerous to the user. A Caution identifies conditions and procedures that can cause damage to the Product or the equipment under test.
Performance Series Thermal Imagers Safety Information Warning To prevent personal injury: • Read all safety information before you use the Product. • Carefully read all instructions. • Use the Product only as specified, or the protection supplied by the Product can be compromised. • Replace the batteries when the low battery indicator shows to prevent incorrect measurements. • Do not use the Product if it operates incorrectly. • Do not use the Product if it is damaged.
TiS10, TiS20, TiS40, TiS45, TiS50, TiS55, TiS60, TiS65 Users Manual Table 1 is a list of symbols used on the Imager and in this manual. Table 1. Symbols Symbol Symbol Risk of Danger. Important information. See manual. Connected to ac power. Battery removed. , 4 Description Description WARNING. LASER RADIATION. Risk of eye damage. Battery status. Battery charging when animated. On/Off Symbol Conforms to European Union directives.
Performance Series Thermal Imagers Accessories Accessories Table 2 is a list of the accessories available for the Imager. Table 2.
TiS10, TiS20, TiS40, TiS45, TiS50, TiS55, TiS60, TiS65 Users Manual Battery Before You Start Two-Bay Battery Charge Base Lithium-ion Smart Battery Hard Carrying Case Soft Case Micro SD Card and Adapter AC Power Supply with Mains Adapters Mini USB-to-USB Cable Quick Reference Guide Safety Information Users Manual, SmartView Software (on USB Drive) • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • Fluke recommends the removable memory card that is supplied with the Imager or available fr
Performance Series Thermal Imagers Before You Start On-Imager AC Power Socket 1. Connect the ac power adapter into an ac wall outlet and connect the dc output to the Imager’s external power socket. , flashes on the display while the battery charges with the ac power adapter. 2. Charge until the charge indicator on the display does not flash. 3. Disconnect ac power adapter when the smart battery is fully charged. Note Make sure that the Imager is near room temperature before you connect it to the charger.
TiS10, TiS20, TiS40, TiS45, TiS50, TiS55, TiS60, TiS65 Users Manual Features and Controls Table 3 shows the Imager features and controls. Table 3. Features and Controls Item 7 8 3 Description Arrow Buttons Function Buttons (F1, F2, and F3) Display Memory View Button Power On/Off Calibration-On-Demand Hand Strap Anchor USB Cable Connection Removable Micro SD Memory Card Slot AC Adapter/External Power Socket 9 2 4 5 1 6 hxk001.
Performance Series Thermal Imagers Before You Start Table 3. Features and Controls (cont.) Item 10 Description Retractable Lens Cover Infrared Camera Lens Visual Light Camera Lens 19 11 16 12 Laser Pointer (Models TiS45, TiS50, TiS55, TiS60, TiS65) Secondary Trigger Primary Trigger 13 14 18 15 17 hxk002.
TiS10, TiS20, TiS40, TiS45, TiS50, TiS55, TiS60, TiS65 Users Manual Power On and Off Controls for Image Capture To turn on or turn off the Imager, push and hold for The two-part trigger is located in the standard trigger position for a pistol-grip device. The larger, green trigger is the primary trigger. The smaller, black trigger is the secondary trigger. >3 seconds. The Imager has Power Save and Auto Off features. For more information about how to set these features, see Settings Menu.
Performance Series Thermal Imagers Before You Start Control Buttons The function and cursor buttons are the primary controls. These buttons move the cursor through the menu structure to set the features.
TiS10, TiS20, TiS40, TiS45, TiS50, TiS55, TiS60, TiS65 Users Manual How to Use the Menus The menus, coupled with the function buttons and arrow buttons, are the access point for: • Thermal image display • Camera features • Measurement • Advanced functions • Memory review • Settings for date, time, language, units, file format • Information about the Imager To open the primary menu, push . The primary menu shows these secondary menus: Measurement, Image, Camera, Memory, and Settings.
Performance Series Thermal Imagers Image Capture stored in the file so you do not need to collate multiple files at a later time. To add photos using the IR-PhotoNotes annotation system: 1. With an infrared image in the buffer, push to open the EDIT IMAGE menu. 2. Push W/X to highlight IR-PhotoNotes. 3. Push to enter the Picture mode. 4. Focus the Imager on the object and push the Image Capture button. 5. Push when done. 6. Push the Image Capture button to capture additional pictures. 7.
TiS10, TiS20, TiS40, TiS45, TiS50, TiS55, TiS60, TiS65 Users Manual Listen to a Voice Annotation (Recording) The i icon identifies each file that has a voice annotation. The voice (audio) recording replays through a Bluetooth headset or when you use SmartView software. To play back: Edit Captured Infrared Image Before you save a file, use the Imager to edit or modify the image.
Performance Series Thermal Imagers Micro SD Memory Card Micro SD Memory Card Temperature Measurement To eject a Micro SD memory card, push in on the exposed edge of the card and then release. The card should pop partially out after you release it. Carefully pull the card out of the slot. All objects radiate infrared energy. The quantity of energy radiated is based on the actual surface temperature and the surface emissivity of the object.
TiS10, TiS20, TiS40, TiS45, TiS50, TiS55, TiS60, TiS65 Users Manual Menus The menus are the access points for thermal image display, camera features, memory setup, and settings for date, time, language, units, file format, and Imager information. Measurement Menu 8. Push: • 1 to set the change and go back to the live view. • 2 or Y to set the change and go back to the previous menu. • 3 to cancel the change and go back to the live view.
Performance Series Thermal Imagers Menus Level for Manual Operation Mode Temperature Span for Manual Operation Mode When put into manual ranging, the level setting moves the thermal span up or down within the total temperature range. See Figure 2. In the live manual mode, the arrow buttons are always available to adjust the level and span. When in manual mode, the span setting contracts or expands in a selected palette in a temperature range within the total range. See Figure 2.
TiS10, TiS20, TiS40, TiS45, TiS50, TiS55, TiS60, TiS65 Users Manual Emissivity Adjustment The correct emissivity values are important for the Imager to make the most accurate temperature measurement calculations. Emissivity of a surface can have a large effect on the apparent temperatures that the Imager observes. Understanding the emissivity of the surface being inspected can, but not always, allow you to obtain more accurate temperature measurements. Note Surfaces with an emissivity of <0.
Performance Series Thermal Imagers Menus Background (Reflected Background Temperature Compensation) Transmission/Transmittance Adjustment (TiS45, TiS55, TiS65 only) Compensation for reflected background temperature is set in the Background tab. Very hot objects or very cold objects can affect the apparent temperature and measurement accuracy of the target or object of interest, especially when surface emissivity is low.
TiS10, TiS20, TiS40, TiS45, TiS50, TiS55, TiS60, TiS65 Users Manual Spot Temperatures The Spot Temperatures are floating HI and LO temperature indicators that move on the display as the temperature measurements of the image fluctuate. To turn on/off the hot and cold spot indicators: 1. Go to Measurement > Spot Temp. 2. Push W/X to highlight ON or OFF. 3. Push or to set the new value.
Performance Series Thermal Imagers Menus Center Box To set the size of the Center Box when enabled: For models TiS50, TiS55, TiS60, and TiS65, the Center Box feature is an adjustable temperature measurement zone (box) that you can center on the infrared image. This zone (box) expands and contracts to different levels within the infrared image. The zone lets the user see an approximate maximum (MAX), average (AVG), and minimum (MIN) temperature measurement in that area.
TiS10, TiS20, TiS40, TiS45, TiS50, TiS55, TiS60, TiS65 Users Manual 22 Grayscale Grayscale Inverted Blue-Red High Contrast Hot Metal Ironbow Amber Amber Inverted Ultra Contrast™ Palettes Grayscale Grayscale Inverted Blue-Red High Contrast Hot Metal Ironbow Amber Amber Inverted TiS60, TiS65 The Palette menu lets you change the false-color presentation of the infrared images on the display (availability varies by model). Some palettes are more suitable for specific applications and can be set as required.
Performance Series Thermal Imagers Menus 3. Push 1 or Z to view the menu. 4. Push W/X to highlight Palette. 5. Push 1 or Z to view the menu. 6. Push W/X to highlight Standard or Ultra Contrast. 7. Push W/X to select a palette. IR-Fusion has different modes that vary by model, see Table 5. (IR-Fusion is not available with the TiS10 model.) Table 5. IR-Fusion Modes by Model 8.
TiS10, TiS20, TiS40, TiS45, TiS50, TiS55, TiS60, TiS65 Users Manual To set the IR-Fusion mode: 1. Push 2. 2. Push W/X to highlight Image. 3. Push 1 or Z to view the menu. 4. Push W/X to highlight IR-Fusion. 5. Push 1 or Z to view the menu. 6. Push W/X to highlight an option. 7. Push: • 1 to set the change and go back to the live view. • 2 or Y to set the change and go back to the previous menu. • 3 to cancel the change and go back to the live view.
Performance Series Thermal Imagers Menus Set High-Temperature Color Alarm To set a high-temperature color alarm: 1. From the Color Alarm menu, push W/X to highlight the option: Set High Alarm. 2. Push Z to open the Color Alarm menu. 3. Push W/X to adjust the temperature setting. 4. Push: • 1 to set the change and go back to the live view. • 2 or Y to set change and go back to the previous menu.
TiS10, TiS20, TiS40, TiS45, TiS50, TiS55, TiS60, TiS65 Users Manual Display Graphics Presentation Logo The options for how you view the on-screen graphics are in the Display menu. These options are Display All, Details and Scale, Scale Only, and Image Only. A Fluke logo shows on the display and captured images. You can choose to turn on or turn off the logo: 1. Push 2. 2. Push W/X to highlight Image. 3. Push 1 or Z to view the menu. 4. Push W/X to highlight Display. 5. Push 1 or Z to view the menu. 6.
Performance Series Thermal Imagers Menus Camera Menu Video The Camera menu has controls and options for secondary camera features such as auto focus, backlight level, and laser pointer. The TiS60 and TiS65 Imagers can record infrared and IR-Fusion™ to the SD card or internal memory in .is3 or .avi format. Backlight To record: The backlight level control is set to low, medium, and high. To set the backlight: 1. Go to Camera > Video. 2. Push W/X to select Video/Audio or Video ONLY.
TiS10, TiS20, TiS40, TiS45, TiS50, TiS55, TiS60, TiS65 Users Manual Auto Capture In the Auto Capture sub-menu, you will see these options: The Auto Capture feature allows you to set the Imager to capture and save an infrared image, or series of images, automatically. Image capture can be triggered manually or with an “apparent temperature” trigger. The temperature trigger is set to start when a value is above or below a set limit.
Performance Series Thermal Imagers Menus Memory Menu Edit Image Files The Memory Menu allows you to review captured images, audio and text annotations, and IR-PhotoNotes™. Files in memory are shown in a large preview format. You can scroll through long lists and open a full-size image. Delete Image Files Change the setting for visible and thermal image and then view all images in the same format.
TiS10, TiS20, TiS40, TiS45, TiS50, TiS55, TiS60, TiS65 Users Manual Settings Menu The Settings menu has adjustments for user preferences such as units of temperature measurement, file format of stored data, “save to” location choice, auto off settings, WiFi and Bluetooth settings, date, time, localization, and language. This menu also has a section that displays information about the Imager such as model number, serial number, and firmware versions. Certificates and licenses are available from this menu.
Performance Series Thermal Imagers Menus Auto Off Date The Auto Off timer is user-defined separately for the LCD and power. The date can be displayed in one of two formats: MM/DD/YY or DD/MM/YY. Note Auto Off is automatically disabled when the Imager is connected to ac power. To set the Auto Off feature: To set the date: 1. Go to Settings > Auto Off. 3. Push to set a new format. 2. Push Y/Z to highlight LCD Time Out or Power Off. 4. Push W/X to highlight Set Date. 3.
TiS10, TiS20, TiS40, TiS45, TiS50, TiS55, TiS60, TiS65 Users Manual 6. Push Y/Z to highlight hours or minutes. The 12 hour format has a selection to set the time as AM or PM. 7. Push W or X to change the setting. 8. Push to set the change. Language To change the display to a different language: 1. Go to Settings > Language. 2. Push W or X to highlight the setting. 3. Push to set a new language.
Performance Series Thermal Imagers Menus WiFi™ Network Infrastructure WiFi is a wireless local area network (WLAN) that links your Imager to other wireless devices using its radio and providing a connection through an access point to the wider Internet. This gives you the ability to move around within a local coverage area and still be connected to the network. To turn on the WiFi Network feature: 1. Go to Settings > Wireless > WiFi > WiFi Network. 2. Push W/X to highlight ON. 3.
TiS10, TiS20, TiS40, TiS45, TiS50, TiS55, TiS60, TiS65 Users Manual 6. Push 1 to save the image and view the image on the phone app. Go to www.flukeconnect.com for more information about how to use the app. Fluke Connect Tools To discover an Imager with Fluke Connect: 1. Turn on the Imager. 2. On the Imager, go to Menu > Fluke Connect. 3. Push W/X or On to select. The Imager starts to scan and presents a list with the ID and name of available tools found within the 20 m distance.
Performance Series Thermal Imagers Menus Advanced Settings Filename Prefix To show the Imager Info: The default filename starts with IR_. You have the option to change this prefix to a different 3-character name with the keyboard. 2. Push W/X to scroll through the menu. Reset Filename You can reset the file number to 00001. Factory Defaults Erases all user-set preferences and restores all of the factory default settings. Imager Information 1. Go to Settings > Advanced > Imager Info. 3.
TiS10, TiS20, TiS40, TiS45, TiS50, TiS55, TiS60, TiS65 Users Manual 3. Push to view the information screen with a list of Open Source Software Licenses. Lens Care 4. Push W/X to scroll to a specific license. Caution To prevent damage to the infrared lens: 5. Push to view the information screen with the specific license agreement. • Carefully clean the infrared lens. The lens has a delicate anti-reflective coating. 6. Push to close the information screen.
Performance Series Thermal Imagers Battery Care To get the best performance from the lithium-ion battery: Warning To prevent personal injury and for safe operation of the Product: • Do not store the battery on the charger for more than 24 hours. • Charge the Imager for a two-hour minimum at threemonth intervals for maximum battery life. • The battery will discharge in about three months if installed in the Imager and powered off.
TiS10, TiS20, TiS40, TiS45, TiS50, TiS55, TiS60, TiS65 Users Manual General Specifications Temperature Operating ............................................................ -10 °C to +50 °C (14 °F to 122 °F) Storage ............................................................... -20 °C to +50 °C (-4 °F to +122 °F) Relative Humidity.................................................. 10 % to 95 % non-condensing Altitude Operating ............................................................
Performance Series Thermal Imagers Detailed Specifications Korea (KCC) ....................................................... Class A Equipment (Industrial Broadcasting & Communication Equipment) Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes. USA (FCC) ......................................................... 47 CFR 15 subpart B.
TiS10, TiS20, TiS40, TiS45, TiS50, TiS55, TiS60, TiS65 Users Manual Imaging Performance IFOV (spatial resolution) Distance to Spot TiS10 .............................................................. 7.8 mRad, D:S 137:1 TiS20 .............................................................. 5.2 mRad, D:S 206:1 TiS40, TiS45 ................................................... 3.9 mRad, D:S 275:1 TiS50, TiS55 ................................................... 2.8 mRad, D:S 377:1 TiS60, TiS65 ....................
Performance Series Thermal Imagers Detailed Specifications Level and Span Smooth Auto-Scaling and Manual scaling of level and span Fast auto setting/switching between manual and auto modes Fast auto rescale in manual mode Minimum Span (in manual mode) ................... 2.5 °C Minimum span (in auto mode) ........................ 5.0 °C Image and Data Storage File Formats ........................................................ BMP, JPG, IS2, IS3, AVI (No analysis software required for .bmp and .
TiS10, TiS20, TiS40, TiS45, TiS50, TiS55, TiS60, TiS65 Users Manual 42