User's Guide Bluetooth Series 1000 Amp Clamp Meters with IR Thermometer AC/DC True RMS Clamp meter Patented
Introduction 1000A True RMS AC/DC Current Clamp models measure: Infrared Temperature AC/DC Voltage Resistance Capacitance Frequency Continuity Diode Specific functions: DC Current, True RMS, Type K thermometer, DC Zero Auto Power OFF Max/Min recording Data Hold Peak Hold Backlit LCD display Careful use of this meter will provide many years of reliable service.
Safety International Safety Symbols This symbol, adjacent to another symbol or terminal, indicates the user must refer to the manual for further information. This symbol, adjacent to a terminal, indicates that, under normal use, hazardous voltages may be present Double insulation SAFETY NOTES • • • • Do not exceed the maximum allowable input range of any function. Do not apply voltage to meter when resistance function is selected. Set the function switch OFF when the meter is not in use.
Description eter Description 1. Current clamp 2. Clamp opening trigger 3. Data Hold Button 4. Mode 5. Peak 6. Range 7. DCA Zero 8. MIN/MAX 9. Backlit LCD Display 10. Test lead input jacks 11. IR thermometer and laser pointer (rear) 12. Backlight /BT active / Store trigger button 13. Laser pointer button 14.
Specifications Function AC Current 50/60 Hz True RMS DC Current AC Voltage 50/60Hz True RMS Range & Resolution Accuracy (% of reading + digits) 400.0 AAC ± (2.5% + 8d) 1000 AAC ± (2.8% + 5d) 400.0 ADC ± (2.5% + 5d) 1000 ADC ± (2.8% + 5d) 400.0 mVAC ± (1.0% + 10d) 4.000 VAC ± (1.5% + 5d) 40.00 VAC 400.0 VAC 600 VAC ± (2.0% + 5d) 400.0 mVDC ± (0.8% + 2d) 4.000 VDC DC Voltage ± (1.5% + 2d) 40.00 VDC 400.0 VDC 600 VDC ± (2.0% + 2d) 400.0Ω ± (1.0% + 4d) 4.000kΩ Resistance ± (1.
Function Range and Resolution Accuracy (% of reading + digits) Temperature (type-K) -4 to 1400 F -20 to 760 C -58 to -4°F ± 9 °F Temp (IR) -4 to 518°F ±2.0% reading or ± 4°F whichever is > o o ± (3%rdg + 9 F) o o ± (3%rdg + 5 C) -50 to -20°C ±5°C -20 to 270°C ±2.
Operation NOTES: Read and understand all Warning and Caution statements in this operation manual prior to using this meter. Set the function select switch to the OFF position when the meter is not in use. AC/DC Current Measurements WARNING: Ensure that the test leads are disconnected from the meter before making current clamp measurements. 1. Set the Function switch to the AAC range or ADC 2. Press the trigger to open jaw. enclose only one conductor.
Resistance Measurements Note: Remove power before making resistance measurements 1. Insert the black test lead into the negative COM terminal and the red into the Ω positive terminal. 2. Set the function switch to the Ω position. 3. Touch the test probe tips across the circuit or component under test. 4. Read the resistance on the LCD display. test lead Capacitance Measurements WARNING: To avoid electric shock, discharge the capacitor under test measuring.
Type K Temperature Measurements 1. Set the function switch to the K Temp position. 2. Insert the Temperature Probe into the negative COM and the TEMP jacks, observing polarity. 3. Touch the Temperature Probe tip to the device under test. Continue to touch the part under test with the probe until the stabilizes. 4. positive reading Read the temperature on the display. The digital reading will indicate decimal point and value.
Non-Contact InfraRed Temperature Measurements 1. Set the function switch to the IR Temp position. 2. Aim the infrared sensor (rear of the meter) at surface to be measured. 3. Press the button in the center of the rotary function switch to turn on the laser pointer and identify the surface spot to be measured. 4. The area of the surface to be measured must spot size as determined by the distance to spot 5. Read the temperature in the display.
Data Hold To freeze the LCD reading, press the HOLD button. While data hold is active, the HOLD icon appears on the LCD. Press the HOLD button again to return to normal operation. Peak Hold The Peak Hold function captures the peak AC or DC voltage or current. The meter can capture negative or positive peaks as fast as 1 millisecond in duration. 1. Turn the function switch to the A or V position. 2. Use the MODE button to select AC or DC . 3. Allow time for the display to stabilize. 4.
FCC Warning This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) T his device may not cause harmful interference, and (2) this device must accept any interference received, incl uding interference that may cause undesired operation. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Do not attempt to disassemble the EX845 instrument by yourself.