DOUBLE DISHDRAWER™ DISHWASHER INTEGRATED DD60DTX6HI INSTALLATION GUIDE BI
SAFETY AND WARNINGS ! WARNING! ! WARNING! Electric Shock Hazard Failure to follow this advice may result in electrical shock or death. Electric Shock Hazard Failure to follow this advice may result in electrical shock or death. • Fitting an integrated panel requires access to electrical service areas. This must be performed by a Fisher & Paykel trained and supported service technician or qualified person.
SAFETY AND WARNINGS WARNING! To reduce the risk of fire, injury to persons or damage when using the appliance, follow the important safety instructions listed below. Read all the guidance before using the appliance. Servicing z Do not repair or replace any part of the appliance unless specifically recommended in this guide. All other servicing should be undertaken by a Fisher & Paykel trained and supported service technician or qualified person.
TOOLS AND COMPONENTS PARTS SUPPLIED z z z TOOLS REQUIRED Keep all packing materials until the unit has been inspected. Inspect the product to ensure there is no shipping damage. If any damage is detected contact the dealer or retailer you bought the product from to report the damage. Fisher & Paykel is not responsible for shipping damage.
PRODUCT DIMENSIONS e PRODUCT DIMENSIONS MM j k PLAN A Overall height* 865 – 925 B Overall width** 599 C Overall depth*** 571 D Height of chassis 855 E Depth of chassis 553 F Ventilation gap between door panels ISOMETRIC 8 G Depth of toe kick recess** b C Custom panel installation 40 – 100 Pre-finished panel installation 40 – 120 H Minimum clearance between toe kick panel and floor I Height of feet* 10 – 70 J Door panel depth**** 16 – 20 K Depth of drawer opening** f A 12 52
CUSTOM PANEL DIMENSIONS Material specifications z z z z h Maximum weight of drawer panels must not exceed 9kg (including handle) The panel should be adequately sealed to withstand moisture (50°C @ 80% RH). The back and sides of the panel should be completely sealed with a waterproof vapour barrier, such as polyurethane, to prevent damage. The back of the panel should be completely flush so that the seal between the panel and the rubber trim is maintained.
CABINETRY DIMENSIONS CLEARANCES C D A E Connections can be located in an adjacent cabinet on either side of the DishDrawer™ Dishwasher*** B A PLAN B ISOMETRIC CABINETRY DIMENSIONS MM CABINETRY CLEARANCES A Minimum inside height* 864 A Minimum clearance to adjacent cupboard door B Inside width 600 B Minimum clearance to corner cupboard* C Minimum inside depth** 578 D Recommended height of adjacent cabinetry 762 E Height of toe kick area*** *depending on adjustment of levelling feet **i
PLUMBING & ELECTRICAL CONSIDERATIONS Hose and cord lengths z z Your services can be installed to either the left-hand or right-hand side of the product in an adjacent cabinet. Refer to 'Preparation' for service access requirements. If the drain hoses supplied are not long enough to reach your services, you may purchase a Fisher & Paykel drain hose extension kit which will extend the drain hoses by 3.6m (part number 525798).
PREPARATION SERVICE ACCESS MOISTURE PROTECTION We recommend locating the service holes on either side of the DishDrawer™ Dishwasher as shown below. If the holes are created through wood, ensure the edges are smooth and rounded If the holes are created through metal, ensure the supplied edge protector is fitted.
PUSH THE PRODUCT INTO THE CAVITY B 1 A A B FIT CUSTOM DOOR PANELS If securing to cabinetry via method A Secure all four side brackets to the DishDrawer™ Dishwasher, aligning bracket A with slot A and bracket B with slot B. 1 Remove both side pins from each drawer by twisting a quarter-turn towards the product front. Pull outwards to remove pin. Ensure the ends of the brackets are not pushed into the chassis. 2 Optionally, fit the two top brackets for additional stability.
FIT THE CUSTOM PANEL 5 Snap the bracket tab to remove. 9 Re-insert both side pins to each drawer by pushing in and twisting a quarter-turn towards the rear of the product to secure panels into place. Attach the Knock-to-Pause module to the panels as shown. 6 Ensure the Knock-to-Pause modules are oriented correctly and are not in contact with the brackets before securing. !0 Insert a Phillips screwdriver into the hole above each side pin and rotate to adjust the panel alignment.
SECURE TO CABINETRY VIA BRACKETS (METHOD A) SECURE TO CABINETRY VIA DRAWER REMOVAL (METHOD B) 1 1 Open the lower drawer and press both locking tabs back to release. Partially open one of the drawers and remove the first screw cover from the trim moulding. Lift the drawer off the runners and carefully set aside on a protected surface. Push runners back in. 2 2 3 Secure to cabinetry via the brackets. Pre-drilling a pilot hole may be required depending on the cabinetry material.
SECURE TO CABINETRY VIA DRAWER REMOVAL (METHOD B) INSTALL PRE-FINISHED TOE KICK Select your preferred pre-finished toe kick based on the depth of your desired toe kick recess. Toe kick depth of 40 – 56mm Flush pre-finished toe kick panel 5 6 Toe kick depth of 56 – 120mm Recessed pre-finished toe kick panel Before refitting the drawer, ensure the hoses are not twisted. 1 Measure toe kick height against the base of the locking tab. Mark cutting location on panel.
INSTALL CUSTOM TOE KICK Align the custom panel to the recessed pre-finished panel, referring to 'Custom panel dimensions' for guidance. 1 Custom panel 2 3 Recessed pre-finished panel Mark a section of the recessed panel to be removed, ensuring it is shorter than the custom panel. On a protected surface, carefully score the toe kick at the marked height. Re-align the custom panel to the recessed panel and secure using the provided screws.
PLUMBING & ELECTRICAL CONNECTION Ø38MM STANDPIPE INSTALLATION Install the drain hose support to the back wall, as close to the underside of the countertop as possible. Refer to 'Plumbing & electrical considerations' for minimum install heights. 1 SINK TRAP/WASTE TEE INSTALLATION 1 Thread wire clips on to the hoses before pulling both hoses through the support guide and fitting to the supplied hose joiner. Secure using the wire clips. Pull both hoses through the support guide and rest in standpipe.
INSTALLER CHECKLIST TO BE COMPLETED BY THE INSTALLER Installation Electrical Ensure all electrical tests have been conducted in accordance with local regulations. Check all parts are installed correctly and are secure. Ensure all clearance gaps have been maintained. Ensure DishDrawer™ Dishwasher is secure and drawer opens and closes freely with no resistance. Ensure panel is fitted correctly to the DishDrawer™ Dishwasher Ensure any packaging or tape securing the racks and spray arm is removed.
TROUBLESHOOTING DISPLAY POSSIBLE CAUSE WHAT TO DO No program indicator lights up when the drawer is opened z A1: Water Supply fault. RINSE + all modifiers ECO, RINSE + all modifiers GLASSWARE, ECO + all modifiers 18 A3: Drawer cannot drain. The drainage hose may be blocked or kinked, or the connection to drainage pipe may be blocked. A6: The spray arm has loosened or come off its mounting, or water pressure is too low, or a combination of low water pressure and excessive foaming.
FISHERPAYKEL.COM © Fisher & Paykel Appliances 2021. All rights reserved. The models shown in this guide may not be available in all markets and are subject to change at any time. The product specifications in this guide apply to the specific products and models described at the date of issue. Under our policy of continuous product improvement, these specifications may change at any time.