DOUBLE DISHDRAWER™ DISHWASHER DD60DA & DD60DC models INSTALLATION GUIDE NZ AU GB IE SG 591151D 05.
1 SAFETY AND WARNINGS WARNING! Electrical shock hazard Before installing the dishwasher, remove the house fuse or open the circuit breaker. This appliance must be earthed. In the event of a malfunction or breakdown, earthing will reduce the risk of electric shock by providing a path of least resistance for electric current. This appliance is equipped with a cord having an equipment-earthing conductor and an earthing plug.
1 SAFETY AND WARNINGS IMPORTANT SAFETY INSTRUCTIONS O O O O O O O O O O 2 Installation of this dishwasher requires basic mechanical and electrical skills. Be sure to leave these Instructions with the Customer. Installation must comply with your local building and electricity regulations. At the completion of the dishwasher installation, the Installer must perform the Final Checklist. Remove all packaging materials supplied with the dishwasher.
2 Drain hose support (1) Phillips 16 mm screws (9) Drain hose joiner (1) Rubber washer for inlet hose (1) (comes already fitted) Wire clip (2) (for securing Drain hose joiner) Moisture protection tape (1) (to prevent moisture damage to cabinetry) PARTS SUPPLIED Clamp (1) (for securing Drain hose joiner) Hexagonal socket for feet adjustment (2) (long & short) Side mounting bracket kit (A and B) (2) OPTIONAL DD60DA models only Prefinished toekick (1) and securing pins (4) Top mounting brackets (2)
3 PRODUCT DIMENSIONS C J DD60DA MODELS DD60DC MODELS H K G F A I L L FRONT PROFILE N M PROFILE B PRODUCT DIMENSIONS A Overall height of product 820-880 B Overall width of product 599 599 C Overall depth of product 573 573 D Depth of chassis (to back of front drawer panel) 553 553 20 20 F Height of chassis 811 811 G Height of drawer front panels 712 712 H Height of upper drawer front panel 393 393 I Height of lower drawer front panel 312 312 8 8 7 7 70-120 72-12
4 CABINETRY DIMENSIONS Q S P R Bracket slots T PLAN PROFILE CABINETRY DIMENSIONS P Inside height of cavity* Q Inside width of cavity R Inside depth of cavity S Recommended height of adjacent cabinet space T Height of toekick space* DD60DA DD60DC MM MM min. 820 min. 820 600 600 min. 560 min. 560 720 720 100-160 100-160 Minimum clearances from adjacent cabinetry * depending on adjustment of levelling feet min. 13 mm clearance from a corner cupboard min.
5 CAVITY PREPARATION COUNTERTOP Water Connection 10 mm Moisture protection tape must be applied Recommended COLD (Maximum 60°C). 3/4“ BSP (GB20) to suit flat washer. Water Pressure These marks indicate formed bracket screw locations, if securing by drawer removal. Water softener models Max. 1 MPa (145 psi) Min. 0.1 MPa (14.5 psi) If there is no side partition, you can construct timber bracing as something to secure into. max. 450mm Models without water softener Max. 1 MPa (145 psi) Min. 0.
6 MAXIMUM DISTANCE OF HOSES & CORD FROM CHASSIS EDGE LEFT HAND SIDE Drain hoses - 2000 mm Inlet hose - 1650 mm Power cord (excl.plug) - 1650 mm RIGHT HAND SIDE Drain hoses - 1800 mm Inlet hose - 1250 mm Power cord (excl.
NOW CHOOSE WHICH INSTALLATION METHOD (A) OR (B) IS MORE SUITABLE FOR YOUR CABINETRY... 7 RECOMMENDED METHOD (A) - SECURE WITHOUT DRAWER REMOVAL (FRAMELESS CABINETRY ONLY) 8-A B ATTACH SIDE MOUNTING BRACKETS Clip all four side mounting brackets into their slots using a flat-bladed screwdriver. Ensure they’re securely fitted before sliding product into cavity.
!0-A SECURE TO THE CABINETRY ON THE SIDES !1-A OPTIONALLY SECURE TO THE CABINETRY ABOVE 1 Open the drawer halfway. Using a flat bladed screwdriver, prise the grey rubber plug out of the trim moulding. (x2) The top mounting brackets will only bend upwards a maximum of 10 mm. Replace the grey rubber plug back into the trim moulding and ensure the trim seal is facing forward. 3 2 Using a small Philips screwdriver, screw through the trim moulding, securing the side mounting bracket to the cabinetry.
7 8-B ALTERNATIVE METHOD (B) - SECURE BY DRAWER REMOVAL 9-B PULL THROUGH HOSES & PUSH INTO THE CAVITY optionally attach the two top mounting brackets (x2) REMOVE THE LOWER DRAWER To prevent kinked hoses Either sit the drawer down on the left hand side (recommended) or rotate the drawer clockwise, resting it on its side after removal. When fitting brackets, ensure the ends are not pushed down into the chassis.
!0-B !1-B SECURE TO THE CABINETRY ON THE SIDES OPTIONALLY SECURE TO THE CABINETRY ABOVE (x2) For further adjustment, using the most appropriate length Hexagonal socket supplied, fully extend levelling feet up to required distance by hand. The top mounting brackets will only bend upwards a maximum of 10 mm. Secure using two pairs of formed brackets. Repeat on the other side of the chassis. Hexagonal socket x4 Ensure product is level and aligning with cabinetry.
FIT THE SUPPLIED TOEKICK PANEL - DD60DA MODELS ONLY Carefully bend and snap off. 91 !4 19 2 min.2 mm clearance 3 4 Once the sides are removed, score/cut all the way down the middle of the toekick. 1 HEIGHT OF TOEKICK min.12 mm clearance Cutoff Sections 115 mm On a board, lay the toekick on its side and carefully score/cut down the corner to where the cutoff will be. There are 3 preset height positions. Carefully bend and snap off the side. Repeat in the opposite corner.
!4 Where the toekick meets the bottom of the tub is the cut-off point FIT THE SUPPLIED TOEKICK PANEL - DD60DC MODELS ONLY 3 Lay the toekick face down on a chopping board or similiar 4 Turn the toekick over and score along the same line 6 Smooth the edges with a file. Be careful of sharp edges.
THERE ARE TWO DIFFERENT PLUMBING AND DRAINAGE OPTIONS. CHOOSE WHICH IS MORE SUITABLE. DRAINAGE OPTION 1 Dishwasher and Ø 38 mm Standpipe DRAINAGE OPTION 2 Dishwasher using drain hose joiner onto sink trap/waste tee Screw Drain hose support to back wall at correct height. If space is limited for fixing, push hose through drain hose support to required height. If space is limited for fixing, push hose through drain hose support to required height. 1 2 3 step 16 min.
!6 CONNECT INLET HOSE TO COLD WATER !7 PLUG PRODUCT IN min. 10mm 3/4” BSP connector 180o No leaks! Ensure the supplied rubber washer is fitted inside the coupling. Tighten coupling with spanner. 1 2 !8 O O TROUBLESHOOTING Excessive water remaining above the filter plate, after the rinse cycle. (This is displayed as an A3 fault) Check for a kinked drain hose, blocked waste connection, highloop not properly installed, drain hose not routed correctly or spray arms not in place. No water supply.
!9 FINAL CHECKLIST TO BE COMPLETED BY THE INSTALLER Check all parts are installed. Ensure that all panels and parts thereof are secure and final electrical tests have been conducted in accordance with local electrical regulations. Turn on the power and water supplies, then open the drawers. You should hear a beep and see a program indicator light up on the control panel. Check the spray arms are in place, mounted correctly and free to rotate, by physically rotating by hand.
17
SINGLE DISHDRAWER™ DISHWASHER DD60SA & DD60SC models INSTALLATION GUIDE NZ AU GB IE SG 591151D 05.
1 SAFETY AND WARNINGS WARNING! Electrical shock hazard Before installing the dishwasher, remove the house fuse or open the circuit breaker. This appliance must be earthed. In the event of a malfunction or breakdown, earthing will reduce the risk of electric shock by providing a path of least resistance for electric current. This appliance is equipped with a cord having an equipmentearthing conductor and an earthing plug.
1 SAFETY AND WARNINGS IMPORTANT SAFETY INSTRUCTIONS O O O O O O O O O O 2 Installation of this dishwasher requires basic mechanical and electrical skills. Be sure to leave these Instructions with the Customer. Installation must comply with your local building and electricity regulations. At the completion of the dishwasher installation, the Installer must perform the Final Checklist. Remove all packaging materials supplied with the dishwasher.
2 Drain hose support (1) Phillips 16 mm screws (7) Drain hose joiner (1) 38 mm bottom fixing screws & metal washers (2) Wire clip (1) (for securing Drain hose joiner) Rubber washer for inlet hose (1) (comes already fitted) PARTS SUPPLIED Clamp (1) (for securing Drain hose joiner) Side mounting bracket kit (A and B) (2) OPTIONAL Top mounting brackets (2) OPTIONAL Moisture protection tape (1) (to prevent moisture damage to cabinetry) If the Drain hoses supplied are not long enough to reach your se
3 PRODUCT DIMENSIONS C H A F FRONT G I PROFILE B DD60SA DD60SC DD60SCT MM MM A Overall height of product 410 454 B Overall width of product 599 599 C Overall depth of product 573 573 D Depth of chassis (to back of front drawer panel) 553 553 E Depth of drawer front panel 20 20 F Height of drawer front panel 393 437 G 410 454 H Height from top of drawer front panel to top of chassis 8 8 I Ventilation gap below drawer front panel 7 7 547 547 PRODUCT DIMENSIONS D E
4 CABINETRY DIMENSIONS L K M Bracket slots PLAN PROFILE CABINETRY DIMENSIONS K Inside height of cavity DD60SA DD60SC DD60SCT MM MM min. 412 min. 456 Inside width of cavity 600 600 M Inside depth of cavity min. 560 min. 560 L Minimum clearances from adjacent cabinetry Cavity height options allow you to match dishwasher with your cabinetry or companion products DD60SA/SC (Standard height models) K min. 412mm DD60SCT (Tall height models) ( ) K Dishwasher min.
5 CAVITY PREPARATION COUNTERTOP 10 mm Moisture protection tape must be applied Water Connection Recommended COLD (Maximum 60°C). These marks indicate formed bracket screw locations, if securing by drawer removal. 3/4“ BSP (GB20) to suit flat washer. If there is no side partition, you can construct timber bracing as something to secure into. Ø 57mm Water Pressure Water softener models Max. 1 MPa (145 psi) Min. 0.1 MPa (14.5 psi) max. 450mm WARNING! min.
6 MAXIMUM DISTANCE OF HOSES & CORD FROM CHASSIS EDGE LEFT HAND SIDE Drain hose - 2000 mm Inlet hose - 1650 mm Power cord (excl.plug) - 2000 mm RIGHT HAND SIDE Drain hoses - 1800 mm Inlet hose - 1250 mm Power cord (excl.
NOW CHOOSE WHICH INSTALLATION METHOD (A) OR (B) IS MORE SUITABLE FOR YOUR CABINETRY... 7 RECOMMENDED METHOD (A) - SECURE WITHOUT DRAWER REMOVAL (FRAMELESS CABINETRY ONLY) 8-A B ATTACH SIDE MOUNTING BRACKETS Clip all four side mounting brackets into their slots using a flat-bladed screwdriver. Ensure they’re securely fitted before sliding product into cavity. B 9-A PULL THROUGH HOSES & PUSH INTO THE CAVITY A A A B A B The mounting slots are in pairs, one on each side diagonally across the product.
!0-A SECURE TO THE CABINETRY ON THE SIDES 1 Using a small Philips screwdriver, screw through the trim moulding, securing the side mounting bracket to the cabinetry. Do not damage the rubber trimseal. Open the drawer halfway. Using a flat bladed screwdriver, prise the grey rubber plug out of the trim moulding. 3 2 Replace the grey rubber plug back into the trim moulding and ensure the trim seal is facing forward. Repeat for all four brackets.
7 8-B ALTERNATIVE METHOD (B) - SECURE BY DRAWER REMOVAL PULL THROUGH HOSES & PUSH INTO THE CAVITY 9-B REMOVE THE LOWER DRAWER 1 To prevent kinked hoses Either sit the drawer down on the left hand side (recommended) or rotate the drawer clockwise, resting it on its side after removal. 3 2 4 Sit the drawer down As you push product in, pull through hoses and cord, ensuring they don’t get kinked or twisted. 3 100 Push drawer runners back in on either side.
!0-B SECURE TO THE CABINETRY ON THE SIDES The product has three pairs of fixing points: Ensure the sound insulation is repositioned correctly. 2 two pairs of formed brackets on either side of the chassis (use 16 mm screws) a pair of fixing holes either side on the bottom (use 38 mm fixing screws & washers) 1 !1-B REFIT THE DRAWER ONTO THE RUNNERS 2 Lift or rotate anti-clockwise the drawer back onto the drawer runners on either side.
THERE ARE TWO DIFFERENT PLUMBING AND DRAINAGE OPTIONS. CHOOSE WHICH IS MORE SUITABLE. DRAINAGE OPTION 2 DRAINAGE OPTION 1 Dishwasher and Ø 38 mm Standpipe Dishwasher using drain hose joiner onto sink trap/waste tee Screw Drain hose support to back wall at correct height. 2 750-883 mm If space is limited for fixing, push hose through drain hose support to required height. Supplied drain hose joiner to suit 19 mm waste tee Screw Drain hose support to back wall at correct height. max.
!3 CONNECT INLET HOSE TO COLD WATER !4 PLUG PRODUCT IN min. 10mm 3/4” BSP connector 180o No leaks! Ensure the supplied rubber washer is fitted inside the coupling. 2 1 Tighten coupling with spanner.
!5 O O TROUBLESHOOTING Excessive water remaining above the filter plate, after the rinse cycle. (This is displayed as an A3 fault) Check for a kinked drain hose, blocked waste connection, highloop not properly installed, drain hose not routed correctly or spray arm not in place. No water supply. (This is displayed as an A1 fault) Check water is connected and turned on. O The dishwasher is beeping continuously There is a fault.
!6 FINAL CHECKLIST TO BE COMPLETED BY THE INSTALLER Check all parts are installed. Ensure that all panels and parts thereof are secure and final electrical tests have been conducted in accordance with local electrical regulations. Turn on the power and water supplies, then open the drawer. You should hear a beep and see a program indicator light up on the control panel. Check the spray arms are in place, mounted correctly and free to rotate, by physically rotating by hand.