FZ200BS Manual VERSION 0.1.0 4. Dip Switch & Interface Socket 번호 FEATURES ON OFF BASIC SET 1 Do not use - - - 2 Do not use - - - Firmware Download Firmware Download Select Mode Do not use - 3 4 Operation Mode -
NO. Port Description 1 VCC(3.3V) 3.FZ200BS Manual VERSION 0.1.0 5. LED Indication / Reset Switch LED State Power LED Power Input Description Red Power LED is lit. Create a network or networks involved in the case, Status LED flashes about Network Creation one second intervals. or Participation Did not create the network or the network did not participate in the case, Status LED blinks rapidly.
FZ200BS Manual VERSION 0.1.0 6. Product Performance List Specification Zigbee Spec. Zigbee 2006 Specification Support Communication Distance 120 M Frequency Range 2405~2480MHz Sensitivity -98 dBm Transmit Power 6 dBm Input Power 5V Current Consumption 00 mA (Max) Operating Temperature -20 ℃ - +50 ℃ Max Operating Temperature -30 ℃ - +80 ℃ Communication Speed 9,600 bps ~ 230,400 bps Antenna Dipole Antenna (4 dBi) Interface USB 7.
FZ200BS Manual VERSION 0.1.0 List Initial set value Device Name FZx00 Vx.x.
FZ200BS Manual VERSION 0.1.0 Program. The signal speed of FZ200BS is basically 115200bps. 9-1. Serial Communication (Hyper Terminal) Program Execute FZ200BS first power ON. Using a USB virtual COM Port FZ200BS By using the device's power is not ON unless you can not run the HyperTerminal. Select [Start][All Programs][Accessories][Communication][Hyper Terminal] in order, and then a window for Connection Set-up comes up. Put a name in the name blank, and click the OK button.
FZ200BS Manual VERSION 0.1.0 Select each blank as below “Bit/sec: 115200, data Bit: 8, Parity: None, Stop Bit: 1, Flow Control: None”, and click the OK button. Hyper Terminal is executed. Hyper Terminal simply does not show any letters inputted. If you check on “Echo typed characters locally” to get to know what letters are inputted, the Recommends between FZ200BS and Hyper Terminal are mixed up. Do not check this.
FZ200BS Manual VERSION 0.1.0 9-2. Set-up FZ200BS Device Type Zigbee Device is classified as Coordinator, Router, and End Device by objective of its operation. There should be Coordinator in the Zigbee Network. A Coordinator should exist in a Zigbee Network. Coordinator manages the Network in the Zigbee Network. Router extends the Network in the Zigbee Network. End Device participates in the Zigbee Network using low power consumption.
FZ200BS Manual VERSION 0.1.0 3. Do not change the Device Type of FZ200BS once the Zigbee Network is configured. ※ It is better to set Coordinator and Router again(Factory Reset) if the Device Type of FZ200BS is changed after the Zigbee Network is already configured. ※ See if the Zigbee Network is configured before resetting FZ200BS to initial set value. The FZ200BS reset automatically participates in the Zigbee Network if the Zigbee Network still exists there. 9-2-1.
FZ200BS Manual VERSION 0.1.0 (6) If “OK” is output from FZ200BS, reboot FZ200BS by inputting “ATZ”. (7) “END START ERROR” is output at the moment when FZ200BS is rebooted. “END START OK” is output if the Zigbee Network is successfully configured. (8) Now, End Device of FZ200BS set-up is completed. Turn the Power of the End Device OFF, and set other devices. 9-2-2. FZ200BS Router Set-up (1) The initial set value of Device is ROUTER. ※ The initial set value of FZ200BS is ROUTER.
FZ200BS Manual VERSION 0.1.0 (6) If “OK” is output from FZ200BS by inputting “ATZ”, reboot FZ200BS. (7) “ROUTER START ERROR” is output at the moment when FZ200BS is rebooted. “ROUTER START OK” is output if the Zigbee Network is successfully configured. (8) Now, Router of FZ200BS Set-up is completed. Turn the Power of the End Device OFF, and set other devices. 9-2-3. FZ200BS Coordinator set-up (1) The initial set value of FZ200BS is ROUTER. (2) FZ200BS device and the PC is connected and powered ON.
FZ200BS Manual VERSION 0.1.0 “ATZ”, reboot FZ200BS. (7) “COORD START OK” is output at the moment when FZ200BS is rebooted. (8) Now, Coordinator of FZ200BS Set-up is completed, and the Zigbee Network is successfully configured. Turn the Power of the Coordinator Device OFF, and set other devices. 9-3. The Zigbee Network Configuration using FZ200BS Try to configure the Zigbee Network after setting the Type for each Device. 9-3-1.
FZ200BS Manual VERSION 0.1.0 HyperTerminal, FZ200BS will reset. (2) “ROUTER START OK” and “TARGET NON” are output. “TARGET NON” means that FZ200BS has yet to set its target device. If “ROUTER START ERROR” is output, which means that no Zigbee Network is around, reset the Device or check if the Coordinator’s status is okay. (3) Router participates in the Zigbee Network and extends the Zigbee Network. (4) Router can transmit Data. 9-3-3.
FZ200BS Manual VERSION 0.1.0 With no target device, data transmission cannot be done even if data is inputted. To set a target device, you need to know an IEEE ADDRESS of the Device. 9-4-1. Searching for an IEEE ADDRESS of Coordinator (1) Input “+++” through Serial port of PC while a Device operates. With Inputting “+++”, the mode of FZ200BS(Coordinator) switches from operation mode to AT-command mode. Data transmission becomes possible when FZ200BS is in an operation mode.
FZ200BS Manual VERSION 0.1.0 (2) FZ200BS outputs a message “TARGET NON”, which means that its target device is not set. (3) Input “+++” through Serial port of PC while FZ200BS operates. “OK” is output. From then, its target device set-up is possible with AT Command. (4) After “OK” is output from FZ200BS “AT+SETTARGET 001551000000000B” through Serial of PC and press “Enter” Key. AT+SETTARGET : It is a command to save the target device’s address.
FZ200BS Manual VERSION 0.1.0 (1) Coordinator to set up the device's power is ON. After running HyperTerminal, FZ200BS will reset. The Zigbee Network is configured by Coordinator. (2) Router to set up the device's power is ON. After running HyperTerminal, FZ200BS will reset. The Device participates in the Zigbee Network. Its target device is automatically set. A message “TARGET OK” is output. If, “TARGET NON” or “TARGET ERROR” is output, its target device is not set. Do the “9-4-2.
FZ200BS Manual VERSION 0.1.0 ERROR LED shows its status. 10. FZ200BS Management TIP Refer to the following to configure Zigbee Network properly in terms of data transmission and Controls. 10-1. FZ200BS Device Type Set-up (1) End Device Set-up Set FZ200BS to End Device before Coordinator and Router is set. (AT+SETEND) Turn the power of the FZ200BS OFF. (2) Router Set-up Set FZ200BS to Router before Coordinator is set. (AT+SETROUTER) Turn the power of the FZ200BS OFF.
FZ200BS Manual VERSION 0.1.0 (1) Turn the power of FZ200BS set to Coordinator ON. (2) Turn the power of Router and End Device which are supposed to make 1 Depth ON. - You can create Devices in 1 Depth up to 8. (3) Turn the power of Router and End Device which are supposed to make 2 Depth ON. - You can create Devices in 2 Depth up to the number of Router in 1 Depth * 8. - Devices are automatically created in 1 Depth if any seats are available in 1 Depth.
FZ200BS Manual VERSION 0.1.0 If there are a lot of Nodes in the Zigbee Network, set the space of time longer for data transmission between the Nodes, Especially, in case of End Device, great caution is required. (A space of data transmission per 10 Devices: minimum 2seconds) The Shorter the space of data transmission is, the more traffic in the Zigbee Network is caused. Do not change target device too often. When you set or change a target device, data for transmission is more created to get its route.
FZ200BS Manual VERSION 0.1.0 (2) Sorts of START MESSAGE COORD START OK : A Device starts as Coordinator and the Zigbee Network is configured properly. Thus, data transmission is possible. COORD START ERROR : A Device starts as Coordinator, and the Zigbee Network Configuration is failed. In this situation, a normal Zigbee Network cannot be configured. After initializing the Device to factory set value (AT&F) and set the Device to Coordinator again, Change the Channel used.
FZ200BS Manual VERSION 0.1.0 See if there is Router participated in the Zigbee Network configured by Coordinator. See if there is Coordinator which has 8 child nodes. See if there is Router which participates in the Zigbee Network and has 8 child nodes. TARGET NON : There is no IEEE ADDRESS of target device saved. In this case, data transmission is not possible. Set a target device to process data transmission. TARGET OK : Target Set-up is properly done by using an IEEE ADDRESS of target device.
FZ200BS Manual VERSION 0.1.0 START OK”. Target device Se-up is possible afterwards. FZ200BS outputs “ROUTER START ERROR” or “END START ERROR” if there is no Zigbee Network around or the Device cannot participate in the Zigbee Network. Target device set-up is prior to data transmission. Turn the power of FZ200BS ON, and then the Device is participated in the Zigbee Network. If FZ200BS has its target device’s Address, FZ200BS searches if its target device is participated in the Zigbee Network.
FZ200BS Manual VERSION 0.1.