PROFESSIONAL WEATHER STATION (WIND AND AIR PRESSURE) Operation Manual About this manual Thank you and congratulations on selecting this professional weather station! We are positive you will enjoy the benefits of accurate weather readings that our instruments offer. This manual will guide you step-by-step through setting up your device. Use this manual to become familiar with your professional weather station, and save it for future reference.
OVERVIEW Display console DC connector USB interface QTY Item 1 Display Console 1 Outdoor sensor(Thermo-hygrometer with solar panel / Rain Gauge / Wind Speed Sensor/ Wind Direction) 1 CD contains PC software 1 Pole 1 pole mounting clamps 1 User manual 2 AA rechargeable batteries Note: Adaptor is not included. Features Time and date, Moon phase. Indoor temperature and humidity Outdoor temperature and humidity Wind chill, wind direction.
High/ low alarm. With message panel showing indication of alarms/Min/Max data, with time stamps Light and UV index Save the data when batteries are changed PC software Upload the data to internet (optional) Set up Guide Before placing and installing all components of the weather station at there final destination, please set up the weather station with all parts being nearby for testing the correct function.
station didn’t receive the signal in 240 minutes, the base station will start search and register new sensor. 3. If the outdoor data lost or a battery change for the transmitter, press the reset button on the solar power cabinet to re-send the signal and set the reregister on at display console to register new transmitter. 4. Do not press any key before outdoor sensor data received, otherwise the outdoor sensor learning mode will be terminated.
Anemometer wind direction sensor Mounting the dual wind sensor holder Mounting the rain sensor Thermo-hygro sensor with solar panel 5
Mounting the thermo-hygro Fix the whole set to a pole same as rain with the two adjustable hoops. sensor sensor The anemometer’s cable is connected to the input on the wind direction sensor. The wind direction sensor’s cable is connected to the input marked Wind on the thermo-hygro sensor The rain sensor’s cable is connected to the input marked Rain on the solar panel The solar panel’s cable is connected to the input marked Rain on the thermo-hygro sensor.
1.Time 2.Indoor Temperature 3.Indoor Humidity 4.Barometric Pressure 5. Barometric Pressure graph 6.Weather icon 7. Message panel showing indication of alarms/Min/Max data 8. Minimum 9.Time stamp 10.RF signal 11.Memory status 12.Wind direction 13.Rain fall 14.Wind speed 15.Dew point 16. Outdoor humidity 17.Outdoor Temperature 18.UV 19.Light 20.Date 2.Initial Display Console Set Up 2.1 The unit will turn on all segments of the LCD for 3 seconds after power on and display setting value.
2.3 Key function SET: Enter the setting mode HISTORY: Display history records / return to normal mode ALARM: Display high or low alarm function / turn on/off the alarm MAX/MIN: Display the MAX, MIN value : Increase the setting parameter/ Move to next message of the selected segment on the message panel : Decrease the setting parameter/ Move to previous message of the selected segment on the message panel : : Move to previous segment/move to main menu during setting.
Console Operation Program mode The screen is divided into 10 segments for selection and there are message display panel on the bottom. There are six program modes: normal, setting mode, history mode, alarm mode, max/min mode and calibrated mode. All the modes can be exited at any time by pressing the HISTORY key, or waiting for a 30 second timeout to take effect. Normally, if the segment selected has multi parts, press SET key to choose different part.
Time and date a) b) c) d) e) Light and UVI a) b) c) d) The max and min temperature/ humidity of the day. The max and min temperature/ humidity since reset. Outdoor temperature/ humidity a) b) The max light of the day. The max light since last reset The max UVI of the day. The max UVI since last reset. Indoor temperature a) b) Week and year (TUESDAY 2013) Alarm time Moon phase. (see moon phases part illustration on Page 19) The DST flag is ON, will display ―DAYLIGHT SAVING TIME‖.
a) b) c) d) Wind and gust speed a) b) c) d) The max wind speed of the day The max wind speed since last reset. The max gust of the day The max gust since last reset. Wind chill, dew point, heat index a) b) c) d) The max and min absolute barometric of the day The max and min absolute barometric since last reset. The max and min relatively barometric of the day The max and min relatively barometric since last reset. The max of dew point, heat index of the day.
b) The max Rainfall since last reset (including rainfall rate during 1 day, 1 week, 1 month, and 1 year). 2. Setting Mode 2.1 In normal mode, press SET key for 2 seconds to enter the setting mode.
RAIN SEASON BEGIN (JAN, FEB, MAR, APR, MAY, JUN, JUL, AUG, SEP, OCT, NOV, DEC) Default: January. The total rain falls before that will be cleared once it comes to 0:00 of January 1st. Means the new statistic annual of rain fall begins from 0:00 of January 1st.Users can choose from January to December PRESSURE SETTING a) Current weather setting. b) Select the synoptic chart, Pre-set the value of weather and Pre-storm value. c) Select the historical time coordinates of pressure graph.
Wind direction can be adjusted by 0-359°.For southern hemisphere installations, the wind direction need to change by 180°. j) WIND FACTOR Wind speed calibration coefficient: default 1 (range is Range is 0.1-2.5) k) RAIN FACTOR Rain factor calibration coefficient: default 1 (range is Range is 0.1-2.5) l) RAIN DAY CORRECT Calibration for total rain falls of 1 day.
l) m) n) o) DEW POINT HIGH ALARM --Set dew point high alarm HEAT INDEX HIGH ALARM --Set heat index high alarm RAIN RATE HIGH ALARM --Set rainfall rate high alarm RAIN DAY HIGH ALARM --Set rainfall day high alarm LOW ALARM SETTING a) In TEMP LOW ALARM--Set indoor temperature low alarm b) In HUMI LOW ALARM --Set indoor humidity low alarm c) In TEMP LOW ALARM --Set outdoor temperature low alarm d) Out HUMI LOW ALARM --Set outdoor humidity low alarm e) ABS BARO LOW ALARM --Set absolute barometric low alarm
temperature. m) RAIN RATE TODAY MAX, RAIN RATE TOTAL MAX -- Maximum Rainfall rate. n) RAIN 24H TOTAL MAX -- Maximum Rainfall within 24 hours. o) RAIN WEEK TOTAL MAX -- Maximum Rainfall within 1 week p) RAIN MONTH TOTAL MAX -- Maximum Rainfall within 1 month q) RAIN YEAR TOTAL MAX -- Maximum Rainfall within 1 year.
indicators Rising Rising rate>= 10% within 30 minutes Rising >= 1℃ within 30 minutes Steady Change rate < 10% within 30 minutes Change rate < 1℃ within 30 minutes Falling Falling rate >= 10% within 30 minutes Falling >= 1℃ within 30 minutes Moon Phases Icon: Northern Hemisphere Moon Phase Description Icon: Southern Hemisphere NEW MOON WAXING CRESCENT MOON FIRST QUARTER MOON WAXING GIBBOUS MOON FULL MOON WANING GIBBOUS MOON LAST QUARTER MOON WANING CRESCENT MOON Beaufort Scales (Wind Speed
Specification Factory Default Settings 1) 2) 3) 4) 5) 6) 7) 8) 9) 10) 11) 12) 13) 14) 15) 16) 17) 18) 19) 20) 21) 22) 23) 24) 25) 26) 27) 28) 29) 30) 31) 32) Time: 1/1/2000 0:00:00 31/12/2099 23:59:59 (default: 1/1/2014 0:00 00 WED) Time zone: -12 +12 12/24 hour format (default: 24hr) DD-MM-YYYY / MM-DD-YYYY / YYYY-MM-DD format (default: DD-MM-YYYY) Temperature unit C or F (default: C) Wind speed units: km/h, m/s, bft, mph, knots (default: km/h) Average wind speed / gust wind speed (default: average
33) 34) 35) 36) Wind speed alarm: 0-50.0m/s (default: 1.8km/h, disable) Guest speed alarm: 0-50.0m/s (default: 3.6km/h, disable) Light high alarm: 0 to 300000 (default: 200000lux, disable) UVI high alarm: 0 to 15 (default: 10, disable) Specifications 1) 2) 3) 4) 5) 6) 7) 8) Indoor temperature measure range: -10 to 60C Outdoor temperature measure range: -40 to 60C Humidity measuring range: 10% to 99% Wind speed measure range: 0 to 50.0m/s Wind direction: 0 to 359 degree Rainfall range: 0 to 9999.
Problem Solution from the display console and wait 10 seconds. Put the batteries back in. 3. Do not touch any buttons for several minutes. 4. The remote sensor search icon will splash on the display. Wait several minutes for this icon to turn off. 5. If the search icon turns off and the outdoor temperature and humidity are still showing dashes (--), the remote sensor is defective.
Problem Solution agree due to signal filtering. The indoor and outdoor humidity sensors should agree within 10 % (the sensor accuracy is ± 5 %) 2. Perform a humidity calibration (reference Section 2.1) Relative pressure does not agree with official reporting station 1. You may be viewing the relative pressure, not the absolute pressure. 2. Make sure you properly calibrate the barometer to an official local weather station (reference Section 2.1) 3. The barometer is only accurate to ± 0.
WeatherSmart PC Software User Manual 1.0 General Information The Weather station is a weather monitoring device that achieves displays and records the weather data from internal and external sensors. Besides the indoor temperature, indoor humidity and air pressure measured by internal sensor, it will receive the outdoor temperature and humidity, wind and rainfall. Light & UVI and Heat index transmitted by outdoor sensor as well.
3.0 Basic Settings of the “Weather Smart” Software After the ―WeatherSmart.exe‖ program has been started, the following main window will appear on the PC screen: All the settings from the base unit is mirrored into the PC software, so once you have done your setting on the base unit, then you don’t need to make any setting changes on the PC software.
4.1.1 Click System button, enters the Setting menu This section is used to set up PC software display, base station units. Once you made your choice, press Save to make the setting effective. 4.1.
This section is used to set the desired time, high or low alarm value for the base unit, as well as able or disable the corresponding alarm function. Once you made your choice, choose Save to make the setting effective. If you don’t want to make any change, just press Cancel and exit without change. 4.1.3 Click Max/Min day button, enters the Max/Min day menu This section is used to display the recorded the min and max alarm time.
4.1.4 Click Max/Min button, enters the Max/Min menu This section is used to display the recorded min and max value recorded with time stamp. Min/Max reset can only be done through key operation on the base station. 4.1.5 Click Language button, enters the Language menu 4.
4.2.1 Click History button, enters the History menu This section is used to display recorded history data in a spread sheet. If you wanted to see all history data in a desired time period, choose the time duration and press Search to reload the history data. With the Export button, you can export the selected history data into excel format and PDF format file for other application purpose.
In this section, you can see the history data plotted in graph format for easier observation.
With the Export as image button, you can export the selected graph into .jpeg format file. You can change the Y axel by scrolling the mouse up and down roller. What to do if graph function is not working This is the most encountered problem with this software. To make the graph function working properly, please check the following step: 1, find the folder where the ―WeahterSmart.exe‖ file is located 2. Create a file name ―reg_graph.bat‖ file with wordpad or notepad editor program 3.
4.3 Upload option Click Upload button, enters the upload menu Note: This feature is only available in WeatherSmart Version 1.8 or greater. 4.3.1 Select Upload|Wunderground.com from the menu bar. User can upload data to website. www.wunderground.com or their own website. If user choose www.wunderground.com, he do not need to set the server, server type and port. If user choose custom, he need to set the server, server type and port.
To upload data to Wunderground.com, you must first register on the Wunderground.com website. Registration is free. Note: How to create a Wunderground.com® account and station ID. 1. Join the Wunderground.com® Community. Visit: https://www.wunderground.com® /members/signup.asp and sign up with Wunderground.com.
2. Join the Personal Weather Station (PWS) network. Visit: http://www.wunderground.com/personal-weather-station/signup or select More | Register Your PWS from the menu at the top of the WeatherUndeground.
Enter your ID obtained and password and select Auto Upload checkbox and Save. Please Note: Make sure you enter the ID in all capitals, and the password exactly as you chose it, both fields are case sensitive. 4.3.2 Upload to WeatherBug Select Upload | WeatherBug from the menu bar.
To upload data to Weatherbug.com, you must first register on the Weatherbug.com website. Registration is free. 1. 2. Visit http://backyard.weatherbug.com/ and select Join if you do not have an account. Once registered with Weatherbug.com you will need to sign up your station. To get started visit: http://backyard.weatherbug.com/group/backyardstations/page/backyardstations Enter your ID, password and station number and select Auto Upload checkbox and Save. 4.3.
4.4 Help option Click About ―WeatherSmart‖ button, enters the About menu 5.0 “WeatherSmart” Software on MAC OS Insert the CD-ROM into the CD-ROM Drive and double click the WeatherSmart software icon, the main interface as below will be opened: The functions of MAC OS are the same to the windows version. Once the device is connected to MAC PC by USB cable, settings, alarms of all weather parameter can be done here. Max/Min record, all history record can be viewed.
5.1 Setting option: Please refer to 4.1.1 5.2 Alarm option: Please refer to 4.1.2 5.
5.4 History option: Please refer to 4.2.1 5.5 Graph Please refer to 4.2.
5.6 Upload option: Please refer to 4.3 5.
Click About WeatherSmart button, enters the About menu to check version information, Special Notes about time synchronization between PC and sub-station: The PC software obtained its own time scale through the time interval marker from the base station history data, and the PC software automatically synchronizes the weather data with a time stamp calculated. Thus the history data file can have different time when the PC time and base station time is not same.
Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Legal Notes We reserve the right to delete or change any image whether or not purposely uploaded onto the server by a user of the touch screen weather station and the WeatherSmart software products.