MEET 0$5,1( PANEL INSTALLER'S MANUAL ENGLISH Version This manual corresponds to FERMAX MARINE MEET PANEL firmware version V02.10.
FERMAX ELECTRÓNICA S.A.U. http://www.fermax.com MEET DIGITAL VIDEO Panel manual available at https://www.fermax.com/qr/meet/ Copyright Notice Fermax and Fermax MARINE MEET panel are trademarks of Fermax Electronica S.A.U. registered in the European Union and other countries. © FERMAX ELECTRÓNICA S.A.U., 2020.
INDEX Product Introduction ................................................................................................... 4 Overview............................................................................................................. 4 Panel Display Screen .......................................................................................... 5 2 Functions Introduction ................................................................................................ 5 Call Apartment .....
Product Introduction Overview Speaker High definition camera 1,2Mpx Lighting for night vision with LEDs 4.
Panel Display Screen Network Status 2 Functions Introduction Call apartment Call guard unit => Concierge Call volume settings Door opening, relay delay settings Exit button connector Voice Synthesizer Door opened, door forced alarm , and tamper alarm Lift control (Only when installed) PIN Access Code Mifare reader Alarm management by access control Face Recognition Electronic Directory Fire Alarm for lock release Page 5
Call Apartment 2.1.1 Enter Apartment Number Visitors need to enter apartment number followed by to confirm. For example, if the resident lives in apartment 201, the visitor should enter: 201 and press . 2.1.2 Call Apartment Via Directory (If enable directory) Access to menu , need to call select directory icon and press B, then search the apartment that the Visitors and press .
Call Guard Unit 2.2.1 Dial Number To Call The visitor or resident can call the guard unit by entering the number 9901 or other number of guard unit followed by to confirm. This call can be made from all Panels. 2.2.1 Dial Bell To Call The visitor or resident need can call the guard unit by entering the number. Access Code Press key “A0” or access menu to access PIN code function, entering the access code followed by B to confirm.
The access code to be defined at web of the panel, Maximum access code 6. Face Recognition Press key “A” two times or access menu to access face recognition function, the camera of the panel will start to read the face information. If the face data is authorized, the door will open and release the lock. The face data is to be added through the management software. Maximum face data 6000.
About Enter code 9999 followed by B to confirm, The About information will show. You can get information about the device name, firmware version, device info, serial no, IP address, MAC address.
3 Configuration via Web Server The panel has an integrated web server, which allows to configure the parameters. This web server is accessed via the panel’s IP address. The browser opens with the configured IP address of the panel. A screen opens requesting a username and password Default IP: 10.1.0.1 Username: admin Password: 123456 Device Information The following information is displayed: the device name, firmware version, device info, serial no, MAC address, IP address.
General Settings Configures the panel type: General entrance panel or block panel. 3.2.1 General Entrance Panel DEVICE NO.: General entrance panel number, between 1 and 9000. TYPE: For General Entrance select G.E.PANEL. The panel can communicate with all devices of the installation. LANGUAGE: select the desired language in the dropdown options. (default option ENGLISH). Refresh the webpage after change the language.
3.2.2 Block Panel BLOCK: Block number, between 001 and 999 (default option 1). DEVICE NO.: Panel Number, between:01-99 (default option 1). TYPE: For block entrance, choose BLOCK PANEL. The panel can communicate with all devices on the same block. LANGUAGE: Select the desired language for the drop-down options. (default option ENGLISH). Refresh the webpage after change the language. INFORMATION: 9901 GUARD UNIT, Prompt information to be displayed on the panel, between 9901-9998, default option 9901.
answer, the call divert APP will start to ring DATE FORMAT: Date format. DATE: Setting the date of the panel. TIME: Setting the time of the panel. TIME ZONE: Setting the time zone of the panel. DST: Enable the daylight saving time option. Select local time zone and save. If the project has no management software the installer can set date, time and time zone manually. If the project has management software, the date and time of panel will synchronizes automatically with the management software.
GATEWAY: Default gateway of the panel (default option 10.254.0.1). DNS: DNS of the panel (default option 8.8.8.8). SOFTWARE IP: IP address of PC where MEET management software is installed. (default option 10.0.0.200). SW. PIN: The pin code is to be used when the panel is registered in MEET management software.
Access DOOR RELAY TIME: Time for lock-release relay remains active (1-9s optional). OPEN DOOR DELAY: The time when the unlocked signal is sent to the start of the relay. The delay time is useful when the lock is not close panel (0-9s optional). DOOR ALARM: An alarm will be issued when the door still open after the normal opening time exceeds the set time. Disable,30s, 60s, 120s, 180s and 250s optional. DOOR FORCED ALARM: An alarm will be issued when an abnormal way of opening the door is detected. EXT.
Page 16
Face Recognition FACE RECOGNITION: Enable or disabled face recognition function. SIMILARITY: High, medium and low options. Default is low. The face data must be added through MEET management software.
IP Camera The monitor can switch to IP CCTV camera video during a conversation. This function allows to configure IP CCTV cameras using RTSP protocol to be displayed as an auxiliary camera to provide different view angles from the door or related areas. NUMBER OF CAMS: IP camera Number. Up to 4 different cameras. CAMERA 1: IP camera name. URL: rtsp://user:password@ip address of ip camera. user:password: for cameras that require a username and password for connection.
SIP Settings ENABLE SIP: Enable or disable sip function. SIP SERVER: SIP server IP address. DOMAIN: Sip server domain. OUTBOUND: Some servers are used when NAT is active on the router. STUN IP: Audio and video NAT traversing public network server IP. STUN PORT: The port of audio and video NAT traversing public network server. H.264: Video coding parameters. SIP USER: The username of sip account. SIP PASS: The password of sip account.
SIP Trunk When there is a VoIP gateway installed on the system or a sip server has a PSTN line. The panel call can be diverted to user's mobile phone or land line telephone through a voice gateway. ENABLE SIP TRUNK: Enable or disable SIP trunk function. URL: sip: sip account @ wan IP: 5062 Advanced The DIRECTORY can be enabled or disabled , Press key “A8” or access menu to access Directory if the directory is be enabled.
Pincode Settings This allows to change the pin code of the web server login. Reset RESTORE FACTORY SETTINGS: The basic settings are restored to the factory, the IP address will be changed to the IP: 10.1.0.1 at the factory. REBOOT DEVICE: The panel will be restarted.
Logout Log out the web server.
4 Installation Installation height Page 23
Connectors 10/100Mbps RJ45 Port. +, ü: 12Vdc Power Input. C, NO, NC: Relay contacts for release lock, the double terminals are the same connection. +5V, ü, WD0, WD1: Wigand-26 protocol output or input. BS, ü: Exit button. NA, ü: Fire alarm. Need connected Block Device NO 1. ü, SP: Door-open sensor. 485+, 485-: To lift control gateway, F01491 (4 relay module).
Technical Parameters Power supply: 12Vdc Standby current: 2 0mA Working current: 500mA Technical specifications of the display: -Size: 4.3 inch -Format: 4:3 -Resolution: 480*272 Camera pixel: 1.2 megapixels 90o visual angle: Vertical 72º, Horizontal 54º Minimum illumination: 0.
)&& :DUQLQJ 7KLV GHYLFH FRPSOLHV ZLWK 3DUW RI WKH )&& 5XOHV 2SHUDWLRQ LV VXEMHFW WR WKH IROORZLQJ WZR FRQGLWLRQV 7KLV GHYLFH PD\ QRW FDXVH KDUPIXO LQWHUIHUHQFH DQG WKLV GHYLFH PXVW DFFHSW DQ\ LQWHUIHUHQFH UHFHLYHG LQFOXGLQJ LQWHUIHUHQFH WKDW PD\ FDXVH XQGHVLUHG RSHUDWLRQ 127( 7KLV HTXLSPHQW KDV EHHQ WHVWHG DQG IRXQG WR FRPSO\ ZLWK WKH OLPLWV IRU D &ODVV % GLJLWDO GHYLFH SXUVXDQW WR SDUW RI WKH )&& 5XOHV 7KHVH OLPLWV DUH GHVLJQHG W