Annex no. 5 Functional Description / User Manual Date: 2012-06-11 m. dudde hochfrequenz-technik Vers. no. 1.
INSTALLATION ID ISC.LRU3000 / ID ISC.
OBID i-scan ® UHF Installation ID ISC.LRU3000/3500 Note Copyright 2013 by FEIG ELECTRONIC GmbH Lange Strasse 4 D-35781 Weilburg Tel.: +49 6471 3109-0 http://www.feig.de With the edition of this document, all previous editions become void. Indications made in this manual may be changed without previous notice. Copying of this document, and giving it to others and the use or communication of the contents thereof are forbidden without express authority. Offenders are liable to the payment of damages.
OBID i-scan ® UHF Installation ID ISC.LRU3000/3500 General information's regarding this document • The sign "" indicates extensions or changes of this manual compared with the former issue. • If bits within one byte are filled with "-", these bit spaces are reserved for future extensions or for internal testing- and manufacturing-functions. These bit spaces must not be changed, as this may cause faulty operation of the reader. • The following figure formats are used: 0...9: 0x00...0xFF: b0...
OBID i-scan ® UHF Installation ID ISC.LRU3000/3500 Contents 1. Safety Instructions / Warning - Read before start-up ! 6 2. Performance Features of Reader Family ID ISC.LRU3000 7 2.1. Performance features ........................................................................................................ 7 2.2. Available Reader types ..................................................................................................... 7 2.3. Available Accessories ...................................
OBID i-scan ® UHF Installation ID ISC.LRU3000/3500 5.2. Reset Push Buttons ........................................................................................................ 23 5.3. Reader Power adjustment............................................................................................... 24 5.3.1. EU-Reader according to EN302 208 .......................................................................... 24 5.3.2. FCC-Reader according to FCC 47 Part 15 ...................................
OBID i-scan ® UHF Installation ID ISC.LRU3000/3500 1. Safety Instructions / Warning - Read before start-up ! • The device may only be used for the intended purpose designed by for the manufacturer. • The operation manual should be conveniently kept available at all times for each user. • Unauthorized changes and the use of spare parts and additional devices which have not been sold or recommended by the manufacturer may cause fire, electric shocks or injuries.
OBID i-scan ® UHF Installation ID ISC.LRU3000/3500 2. Performance Features of Reader Family ID ISC.LRU3000 2.1. Performance features The Reader has been developed for reading passive data carriers, so-called „Smart Labels“, using an operating frequency in the UHF range. 2.2. Available Reader types The following Readers are available: Table 1: Available Reader Types Reader type Description ID ISC.LRU3500-EU Device version for Europe with PoE (max. 4Watt) ID ISC.
OBID i-scan ® UHF Installation ID ISC.LRU3000/3500 3. Installation The Reader is designed for wall-mount, including outdoors. Holes for mounting on a wall are provided in the housing. It is not necessary to open the reader housing mounting. 68 (2.68) 25,5 (1.00) 34 (1.34) 157,3 (6.19) 261,3 (10.29) 241,7 (9.
OBID i-scan ® UHF Installation ID ISC.LRU3000/3500 4. Terminals On the lower side of the reader housing the different cable connectors are positioned. Figure 2: Connection Overview shows the arrangement of the connectors and Table 3: Connection terminals shows which connection for the different cables are used for. Table 4: Push button function shows the available push buttons.
OBID i-scan ® UHF Installation ID ISC.LRU3000/3500 4.1. Antenna Connection The external SMA antenna connectors are positioned on the lower side of the reader. The maximum tightening torque for the SMA sockets is 0.45 Nm (4.0 lbf in). CAUTION: Exceeding the tightening torque will destroy the plug.
OBID i-scan ® UHF Installation ID ISC.LRU3000/3500 4.2. Power Supply 4.2.1. Power Supply via connection X1 The supply voltage of 24 V DC has to be connected to Terminal X1. Table 6: Pin assignment for power supply Terminal Abbreviation Description X1 / Pin 1 VDC Vcc – supply voltage 24VDC +-5% X1 / Pin 2 GND Ground – supply voltage Figure 4: Connection for the power supply CAUTION: The reader has to be supplied by a limited power supply (e.g.
OBID i-scan ® UHF Installation ID ISC.LRU3000/3500 4.2.2. Power Supply via Power over Ethernet (PoE) Optional the reader (only LRU3500) can be powered via the LAN connector on X2 with the use of a PoE „Power over Ethernet“ power supply according to IEEE802.3at*, Class4 (30/25,5Watt). The DC supply can be achieved via the free pin’s 4,5 and 7,8 (Midspan-Power). Also a “Phantom Powering” (Inline-Power) via the signal pin’s 1,2,3,and 6 is possible.
OBID i-scan ® UHF Installation ID ISC.LRU3000/3500 4.3. Interfaces 4.3.1. Ethernet Interface on connector X2 The Reader has an integrated 10 / 100 base-T network port for an RJ-45. Connection is made on X2 and has an automatic “Crossover Detection” according to the 100BASE-T Standard. With structured cabling CAT 5 cables should be used. This ensures a reliable operation at 10 Mbps or 100 Mbps. The prerequisite for using TCP/IP protocol is that each device has a unique address on the network.
OBID i-scan ® UHF Installation ID ISC.
OBID i-scan ® UHF Installation ID ISC.LRU3000/3500 Figure 9: Wiring example for connecting the RS232 interface RS485-Schnittstelle X6 4.3.5. RS485 Interface on connector X6 The connection of the RS485 interface take place via the X6 connector as well. The interface parameter can be configured via software protocols.
OBID i-scan ® UHF Installation ID ISC.LRU3000/3500 4.3.5.1. Address assignment of RS485 for bus operation For bus operation the Reader can be assigned the required bus address via software. The address is assigned by the host computer. The software is used to assign addresses “0” through “254” to the Reader. A potential termination of the interface bus can be configured by the software as well.
OBID i-scan ® UHF Installation ID ISC.LRU3000/3500 The data-clock interface is only available in Scan-Mode. The data-clock interface cannot be used to configure the reader. The digital outputs OUT1 and OUT2 are not available, if the data-clock interface is activated. The data as well as the clock need to be supplied with an external voltage. The output is configured for max. 24 V DC / 30 mA.
OBID i-scan ® UHF Installation ID ISC.LRU3000/3500 4.4. Digital Inputs on connector X5 The optocouplers on Terminal X5 are galvanically isolated from the Reader electronics and must therefore be externally supplied. Figure 13: Optocoupler pin-outs IN1 – IN5 Figure 14: Internal and possible external wiring of the optocoupler inputs Optocoupler input (X5/1-5): The input LED associated with the optocoupler is connected internally to a series resistor of 500 Ω.
OBID i-scan ® UHF Installation ID ISC.LRU3000/3500 Table 11: Required external series resistor Rext External voltage Uext Required external series resistor Rext 5 V ... 10 V --- 11 V ... 15 V 270 Ω 16 V ... 20 V 560 Ω 21 V ... 24 V 820 Ω NOTE: The input is configured for a maximum input voltage of 5-10 V DC and an input current of max. 20 mA. Polarity reversal or overload on the input will destroy it. 4.5. Outputs on connector X5 4.5.1.
OBID i-scan ® UHF Installation ID ISC.LRU3000/3500 Figure 16: Internal and possible external wiring of the optocoupler-outputs OUT1-2 CAUTION: The output is configured for max. 24 V DC / 30 mA. Polarity reversal or overload on the output will destroy it. The output is intended for switching resistive loads only. 4.5.2. Relay outputs on connector X5 There are 3 relay outputs available on connector X5.
OBID i-scan ® UHF Installation ID ISC.LRU3000/3500 CAUTION: The relay output is configured for max. 24 V DC / 2 A constant load. The switching current must not exceed 1A. The relay output is intended for switching resistive loads only. If an inductive load is connected, the relay contacts must be protected by means of an external protection circuit.
OBID i-scan ® UHF Installation ID ISC.LRU3000/3500 5. Operating and Display Elements 5.1. Status LEDs Table 12: Configuration of the LEDs Host Communication Warning ANT 1- 4 Input Output RUN Green Yellow Red ON OFF ON Boot sequence (ca.
OBID i-scan ® UHF Green Installation Yellow Red ID ISC.LRU3000/3500 Description Configurations-Reset: FLASH FLASH FLASH (light in sequence) ON ON ON While T1 is pushed and hold for maximal 5s After T1 has been pushed and hold for 5s. Configuration Reset has been finished. Input / Output LED (yellow): Configurable LED. Can display the status of a digital input or output ANT 1 – 4: Green HF Power switched on Blue Tag-Detect Red Antenna impedance error (> 50Ohm or <50Ohm) 5.2.
OBID i-scan ® UHF Installation ID ISC.LRU3000/3500 5.3. Reader Power adjustment To achieve the optimum reading performance it is necessary to set the reader output power to the highest allowed value. This depends on the used reader type (EU / FCC) and the regulation in the country were the reader is used. 5.3.1. EU-Reader according to EN302 208 According to the standard EN302 208 the maximum radiated power is 2 W e.r.p. (Effective Radiated Power) in countries of the European Union.
OBID i-scan ® UHF Installation ID ISC.LRU3000/3500 5.3.2. FCC-Reader according to FCC 47 Part 15 According to the FCC approval, Title 47, Part15 the maximum output power of the reader is limited to 1 W (30dBm). The maximum radiated power of the antenna should not increase more then 4 W e.i.r.p.
OBID i-scan ® UHF Installation ID ISC.LRU3000/3500 6. Technical Data MECHANICAL DATA Housing Aluminum powder-coated Dimension (W x H x D) 261,3 mm x 157,3 mm x 68 mm) 10.29 inch x 6.19 inch x 2.68 inch Weight 2,0 kg (4.4 lb) Protection Class IP 53 (with protection cap IP64) Colour RAL 9003 (Signal White) ELECTRICAL DATA Power Supply • ID ISC.LRU3000 • ID ISC.LRU3500 24 V DC ± 5 % (Noise Ripple: max. 150 mV) 24 V DC ± 5 % (Noise Ripple: max. 150 mV) or Power over Ethernet (min.
OBID i-scan ® UHF Installation ID ISC.LRU3000/3500 Inputs • 5 x Optocoupler max.
OBID i-scan ® UHF Installation ID ISC.
OBID i-scan ® UHF Installation ID ISC.LRU3000/3500 7. Radio Approvals 7.1. Europe (CE) When properly used this radio equipment conforms to the essential requirements of Article 3 and the other relevant provisions of the R&TTE Directive 1999/5/EC of March 99.
OBID i-scan ® UHF Installation ID ISC.LRU3000/3500 7.2.
OBID i-scan ® UHF Installation ID ISC.LRU3000/3500 7.3. USA (FCC) and Canada (IC) 7.3.1. USA (FCC) and Canada (IC) warning notices Product name: ID ISC.LRU3000-FCC ID ISC.LRU3500-FCC Reader name: ID ISC.LRU3000-FCC ID ISC.LRU3500-FCC FCC ID: IC: Notice for USA and Canada PJMLRU3000 6633A-LRU3000 This device complies with Part 15 of the FCC Rules and with RSS-210 of Industry Canada. Operation is subject to the following two conditions.
OBID i-scan ® UHF Installation ID ISC.LRU3000/3500 7.3.2. Label Information The following information must be placed at the outer side of the housing in which the reader is mounted. Contains FCC ID PJMLRU3000 Contains IC: 6633A-LRU3000 7.3.3. Installation with FCC / IC Approval FCC-/IC-NOTICE: To comply with FCC Part 15 Rules in the United States / with IC Radio Standards in Canada, the system must be professionally installed to ensure compliance with the Part 15 certification / IC certification.