INSTALLATION ID ISC.LRU1002 (EU: 4127.001.00; FCC: 4128.001.00) UHF Long Range Reader final – public (B) 2019-09-04 – M61110-5e-ID-B.
IDENTIFICATION Installation ID ISC.LRU1002 Note Copyright 2017-2019 by FEIG ELECTRONIC GmbH Lange Strasse 4 D-35781 Weilburg Tel.: +49 6471 3109-0 http://www.feig.de With the edition of this document, all previous editions become void. Indications made in this manual may be changed without previous notice. Copying of this document, and giving it to others and the use or communication of the contents thereof are forbidden without express authority. Offenders are liable to the payment of damages.
IDENTIFICATION Installation ID ISC.LRU1002 Contents 1. Safety Instructions / Warning - Read before start-up ! 5 2. Performance Features of Reader Family ID ISC.LRU1002 6 2.1. Performance features ........................................................................................................ 6 2.2. Available reader types....................................................................................................... 6 3. Installation 7 4. Terminals 8 4.1. Antenna Connection .......
IDENTIFICATION Installation ID ISC.LRU1002 5.3.1. EU reader according to EN302 208............................................................................ 23 5.3.2. FCC-Reader according to FCC 47 Part 15 ................................................................. 24 6. Technical Data 25 7. Radio Approvals 28 7.1. Europe (CE)...................................................................................................................... 28 7.2. USA (FCC) and Canada (IC) ...............
IDENTIFICATION Installation ID ISC.LRU1002 1. Safety Instructions / Warning - Read before start-up ! The device may only be used for the intended purpose designed by for the manufacturer. The operation manual should be conveniently kept available at all times for each user. Unauthorized changes and the use of spare parts and additional devices which have not been sold or recommended by the manufacturer may cause fire, electric shocks or injuries.
IDENTIFICATION Installation ID ISC.LRU1002 2. Performance Features of Reader Family ID ISC.LRU1002 2.1. Performance features The reader has been developed for reading passive data carriers, so-called „Smart Labels“, using an operating frequency in the UHF range. The output power is configurable in the range between 100 mW and 2 W. This allows read ranges of up to 12 m. 2.2.
IDENTIFICATION Installation ID ISC.LRU1002 3. Installation The Reader is designed for wall-mount, including outdoors. Outdoors the reader should be mounted like shown in the picture below to ensure the watertightness of the device. Holes for mounting on a wall with countersunk head screws are provided in the housing. The maximum head screw diameter should not exceed 8,0 mm. The thread diameter is 5,3 mm (M5 screws). The screws must have a minimum length of 45 mm depending on the installation situation.
Installation IDENTIFICATION ID ISC.LRU1002 4. Terminals On the lower side of the reader housing different connectors are positioned. Figure 2 shows the arrangement of the connectors and Table 2: Connection terminals gives an overview on the available interfaces and signals. Table 3: Push button function shows the available push buttons.
Installation IDENTIFICATION ID ISC.LRU1002 4.1. Antenna Connection The external SMA antenna connectors are positioned on the lower side of the reader. The maximum tightening torque for the SMA sockets is 0.45 Nm (4.0 lbf in). For supplying a DC voltage to external components e.g. the UHF antenna multiplexer ID ISC.ANT.UMUX, it is possible to enable a supply voltage (24 V DC / max. 500mA) on the antenna cable. This need to be configured in the reader.
Installation IDENTIFICATION ID ISC.LRU1002 4.2. Power Supply 4.2.1. Power Supply via connection X2 The supply voltage of 24 V DC has to be connected to Terminal X2. Figure 4: Connector X2 Pin assignment for power supply Table 5: Pin assignment for power supply Terminal Abbreviation Description X2 / Pin 1 VDC Supply voltage 24 V DC ±20 % X2 / Pin 2 GND Ground – supply voltage CAUTION: The reader has to be supplied by a limited power supply according EN 62368-1 Chapter Q.
Installation IDENTIFICATION ID ISC.LRU1002 4.3. Interfaces 4.3.1. Ethernet Interface on connector X1 The Reader has an integrated 10 / 100 base-T network port for an RJ-45. Connection is made on X1 and has an automatic “Crossover Detection” according to the 100BASE-T Standard. With structured cabling STP CAT 5 cables should be used. This ensures a reliable operation at 10 Mbps or 100 Mbps. The prerequisite for using TCP/IP protocol is that each device has a unique IP address on the network.
Installation IDENTIFICATION ID ISC.LRU1002 Via an optionally available USB On-The-Go adapter cable, the interface can be converted to a USB host interface. The adapter cable allows the connection of a USB memory stick to the reader. By means of the USB stick various service functions can be carried out e.g. the read-out of log and service files and uploading of a configuration file. Figure 6: USB On-The-Go adapter cable 4.3.2.2.
IDENTIFICATION Installation ID ISC.LRU1002 While connecting the USB flash drive on a running reader, the reader will store the configuration as a editable and readable CSV-file (CONFIG.INI) on the USB flash drive. This file will be stored in the main directory for easy coping of the configuration (4.3.2.4. Copy the configuration onto the reader (Config-Cloning)). Additionally the same file will be stored in the subdirectory named after the according Device-ID (see type plate of the reader).
Installation IDENTIFICATION ID ISC.LRU1002 4.3.3. RS232 Interface on connector X4 The RS232 interface is connected on X4. The transmission parameters can be configured by means of software protocol. Figure 7: RS232 interface pin-outs on X4 Table 7: Pin Assignment RS232 Interface Pin Number at Connector X4 Pin Assignment 1 RS232 – RxD 2 RS232 – TxD 3 GND Figure 8: Wiring example for connecting the RS232 interface to a 9 pin D-SUB plug FEIG ELECTRONIC GmbH Page 14 of 31 M61110-5e-ID-B.
Installation IDENTIFICATION ID ISC.LRU1002 4.3.4. Data-Clock Interface on connector X4 The connection of the data-clock interface takes place via the digital Outputs OUT1 and OUT2 at connector X4. The wire for the clock (Data-0) needs to be connected to connector OUT1-E, the wire for the data (Data-1) needs to be connected to connector OUT2-E.
IDENTIFICATION Installation ID ISC.LRU1002 See Notes below for resistor values Figure 10: Wiring Example NOTE: Please consider possible limitations of the Wiegand Controller regarding the used supply voltage. The necessity of the external pull down resistor is depending on the inner circuit of the used Wiegand Controller In dependency on the inner circuit of the used Wiegand Controller it is necessary to use external serial resistors to limit the current on the data and clock wires.
Installation IDENTIFICATION ID ISC.LRU1002 4.4. Inputs and Outputs on connector X4 4.4.1. 24 V DC voltage on connector X4 A 24 V DC voltage can be received on Pin 4 of connector X4. It can be used e.g. to drive the digital Inputs and Outputs of the reader. Figure 11: 24 V DC Voltage Table 9: Pin Assignment 24 V DC Voltage Pin Number at Connector X4 Pin Assignment 3 GND 4 24 V DC CAUTION: The maximum current is limited to 750 mA. FEIG ELECTRONIC GmbH Page 17 of 31 M61110-5e-ID-B.
Installation IDENTIFICATION ID ISC.LRU1002 4.4.2. Digital Inputs on connector X4 The optocouplers on Terminal X4 are galvanically isolated from the Reader electronics and must therefore be externally supplied.
Installation IDENTIFICATION ID ISC.LRU1002 4.4.3. Digital outputs on connector X4 The transistor connections, collector and emitter, of the optocoupler output are galvanically isolated from the Reader electronics and are carried to the outside without any internal ancillary circuitry on Terminal X4. The output must therefore be powered by an external power supply.
Installation IDENTIFICATION ID ISC.LRU1002 4.4.4. Relay output on connector X4 There are 2 relay outputs (normally open) available on connector X4. Figure 16: Relay outputs REL1 / REL2 Table 12: Pin Assignment Relay Outputs REL1 / REL2 Pin Number at Connector X4 Pin Assignment 5 REL1-NO 6 REL1-COM 15 REL2-NO 16 REL2-COM CAUTION: The relay outputs are configured for max. 24 V DC / 2 A constant load. The switching current must not exceed 1A.
Installation IDENTIFICATION ID ISC.LRU1002 5. Operating and Display Elements 5.1.
Installation IDENTIFICATION ID ISC.LRU1002 5.2. Reset Push Button T1 By means of the push button T1 a complete configuration reset can be performed. The push button is positioned in the middle between the antenna connectors ANT3 and ANT4. Figure 18 shows the position of the push button. It is located inside the reader housing. To press the reset button T1 you should use a paper clip.
Installation IDENTIFICATION ID ISC.LRU1002 5.3. Reader Power Adjustment To achieve the optimum reading performance it is necessary to set the reader output power to the highest allowed value. This depends on the used reader type (EU / FCC) and the regulation in the country were the reader is used. 5.3.1. EU reader according to EN 302 208 According to the standard EN 302 208 the maximum radiated power is 2 W e.r.p. (Effective Radiated Power) in countries of the European Union.
Installation IDENTIFICATION ID ISC.LRU1002 5.3.2. FCC Reader according to FCC 47 Part 15 and IC RSS-247, Issue 2 According to the FCC approval, Title 47, Part 15 and IC RSS-247, Issue 2 the maximum output power of the reader is limited to 1 W (30dBm). The maximum radiated power of the antenna should not increase more than 4 W e.i.r.p. Due to these facts the antenna ID ISC.ANT.
IDENTIFICATION Installation ID ISC.LRU1002 6. Technical Data MECHANICAL DATA Housing Aluminum powder-coated Dimension (W x H x D) 260 mm x 157 mm x 68 mm 10.2 inch x 6.2 inch x 2.7 inch Weight 1,8 kg (4.0 lb) Protection Class IP 53 (with protection cap IP64) Colour RAL 9003 (Signal White) ELECTRICAL DATA Power Supply 24 V DC ± 20 % (Noise Ripple: max. 150 mV) Current Consumption max. typ.
IDENTIFICATION Interfaces Installation ID ISC.LRU1002 RS232 USB Mini (USB 2.
IDENTIFICATION Installation ID ISC.LRU1002 APPLICABLE STANDARDS Radio Regulation Europe USA Canada EN 302 208 FCC 47 CFR Part 15 IC RSS-247, Issue 2 EMC EN 301 489 Safety Low Voltage Human Exposure FEIG ELECTRONIC GmbH EN 62368-1 EN 50364 Page 27 of 31 M61110-5e-ID-B.
IDENTIFICATION Installation ID ISC.LRU1002 7. Radio Approvals 7.1. Europe (CE) Hereby, FEIG ELECTRONIC GmbH declares that the radio equipment type ID ISC.LRU1002 is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address: http://www.feig.de/en/downloads-support/declarations-of-conformity.html Performance Classification according to ETSI EN 301 489: Class 2 FEIG ELECTRONIC GmbH Page 28 of 31 M61110-5e-ID-B.
Installation IDENTIFICATION ID ISC.LRU1002 7.2. USA (FCC) and Canada (IC) 7.2.1. USA (FCC) and Canada (IC) warning notices Product name: FCC ID: IC: Notice for USA and Canada ID ISC.LRU1002-FCC PJMLRU1002A 6633A-LRU1002A This device complies with Part 15 of the FCC Rules and with RSS-210 of Industry Canada. Operation is subject to the following two conditions.
IDENTIFICATION Installation ID ISC.LRU1002 7.2.2. Label Information The following information must be placed at the outer side of the housing in which the reader is mounted. Contains FCC ID PJMLRU1002A Contains IC: 6633A-LRU1002A 7.2.3. Installation with FCC / IC Approval FCC-/IC-NOTICE: To comply with FCC Part 15 Rules in the United States / with IC Radio Standards in Canada, the system must be professionally installed to ensure compliance with the Part 15 certification / IC certification.
Installation IDENTIFICATION ID ISC.LRU1002 ANNEX A - Accessories Following optional accessories are available: Order No. Article Description Plastic Sealing Cap for Reader Connectors with Steel Conduit Pipe Thread (PG) for ID ISC.LRU3x00 and ID ISC.LRU1002 3558.000.00 ID ISC.LR.CSC-IP64 Connector Sealing Cap 3831.000.00 ID ISC.LRU3x00-MS DIN-RAIL mounting kit with self-tapping screws EU: 3198.000.00 FCC: 3685.000.00 EU: 3199.000.00 FCC: 3686.000.00 Mounting Rail Set for ID ISC.LRU3x00 and ID ISC.