INSTALLATION ID ISC.LRU1002 UHF Long Range Reader final – public (B) 2014-03-18 – M31010-1e-ID-B.
OBID i-scan ® UHF Installation ID ISC.LRU1002 Note Copyright 2013-14 by FEIG ELECTRONIC GmbH Lange Strasse 4 D-35781 Weilburg Tel.: +49 6471 3109-0 http://www.feig.de With the edition of this document, all previous editions become void. Indications made in this manual may be changed without previous notice. Copying of this document, and giving it to others and the use or communication of the contents thereof are forbidden without express authority. Offenders are liable to the payment of damages.
OBID i-scan ® UHF Installation ID ISC.LRU1002 Contents 1. Safety Instructions / Warning - Read before start-up ! 5 2. Performance Features of Reader Family ID ISC.LRU1002 6 2.1. Performance features ........................................................................................................ 6 2.2. Available Reader types ..................................................................................................... 6 2.3. Available Accessories ........................................
OBID i-scan ® UHF Installation ID ISC.LRU1002 6. Technical Data 23 7. Radio Approvals 26 7.1. Europe (CE)...................................................................................................................... 26 7.2. Declaration of Conformity (Directive 1999/5/EC - R&TTE) ............................................ 27 7.3. USA (FCC) and Canada (IC) ............................................................................................ 28 7.3.1.
OBID i-scan ® UHF Installation ID ISC.LRU1002 1. Safety Instructions / Warning - Read before start-up ! The device may only be used for the intended purpose designed by for the manufacturer. The operation manual should be conveniently kept available at all times for each user. Unauthorized changes and the use of spare parts and additional devices which have not been sold or recommended by the manufacturer may cause fire, electric shocks or injuries.
OBID i-scan ® UHF Installation ID ISC.LRU1002 2. Performance Features of Reader Family ID ISC.LRU1002 2.1. Performance features The Reader has been developed for reading passive data carriers, so-called „Smart Labels“, using an operating frequency in the UHF range. The output power is configurable in steps of 100 mWatts in the range between 100 mWatts and 2 Watts. This allows read ranges of up to 8m. 2.2.
OBID i-scan ® UHF Installation ID ISC.LRU1002 3. Installation The Reader is designed for wall-mount, including outdoors. Holes for mounting on a wall are provided in the housing. It is not necessary to open the reader housing for mounting. 68 (2.68) 25,5 (1.00) 34 (1.34) 157,3 (6.19) 261,3 (10.29) 241,7 (9.52) Figure 1: Installation Drawing FEIG ELECTRONIC GmbH Page 7 of 29 M31010-1e-ID-B.
OBID i-scan ® UHF Installation ID ISC.LRU1002 4. Terminals On the lower side of the reader housing the different cable connectors are positioned. Figure 2: Connection Overview shows the arrangement of the connectors and Table 3: Connection terminals shows which connection for the different cables are used. Table 4: Push button function shows the available push buttons.
OBID i-scan ® UHF Installation ID ISC.LRU1002 4.1. Antenna Connection The external SMA antenna connectors are positioned on the lower side of the reader. The maximum tightening torque for the SMA sockets is 0.45 Nm (4.0 lbf in). CAUTION: Exceeding the tightening torque will destroy the plug.
OBID i-scan ® UHF Installation ID ISC.LRU1002 4.2. Power Supply 4.2.1. Power Supply via connection X2 The supply voltage of 24 V DC has to be connected to Terminal X2. Figure 4: Connector X2 Pin Assignment Table 6: Pin assignment for power supply Terminal Abbreviation Description X2 / Pin 1 VDC Vcc – supply voltage 24 V DC ±5% X2 / Pin 2 GND Ground – supply voltage CAUTION: The reader has to be supplied by a limited power supply (e.g.
OBID i-scan ® UHF Installation ID ISC.LRU1002 4.3. Interfaces 4.3.1. Ethernet Interface on connector X1 The Reader has an integrated 10 / 100 base-T network port for an RJ-45. Connection is made on X1 and has an automatic “Crossover Detection” according to the 100BASE-T Standard. With structured cabling STP CAT 5 cables should be used. This ensures a reliable operation at 10 Mbps or 100 Mbps. The prerequisite for using TCP/IP protocol is that each device has a unique address on the network.
OBID i-scan ® UHF Installation ID ISC.LRU1002 4.3.3. RS232 Interface on connector X4 The RS232 interface is connected on X4. The transmission parameters can be configured by means of software protocol. Figure 6: RS232 interface pin-outs on X4 Table 8: Pin Assignment RS232 Interface Pin Number at Connector X4 Pin Assignment 1 RS232 – RxD 2 RS232 – TxD 3 GND Figure 7: Wiring example for connecting the RS232 interface to a 9 pin D-SUB plug FEIG ELECTRONIC GmbH Page 12 of 29 M31010-1e-ID-B.
OBID i-scan ® UHF Installation ID ISC.LRU1002 4.3.4. Data-Clock Interface on connector X4 The connection of the data-clock interface take place via the digital Outputs OUT1 and OUT2 at connector X4. The wire for the clock needs to be connected to connector OUT1-C, the wire for the data needs to be connected to connector OUT2-C.
OBID i-scan ® UHF Installation ID ISC.LRU1002 Figure 9: Wiring Example NOTE: Please consider possible limitations of the Wiegand Controller regarding the used supply voltage. In dependency on the inner circuit of the used Wiegand Controller it is necessary to use external serial resistors to limit the current on the data and clock wires. The necessity of the external pull down resistor is depending on the inner circuit of the used Wiegand Controller FEIG ELECTRONIC GmbH Page 14 of 29 M31010-1e-ID-B.
OBID i-scan ® UHF Installation ID ISC.LRU1002 4.4. Digital Input on connector X4 The optocoupler on Terminal X4 is galvanically isolated from the Reader electronics and must therefore be externally supplied. Figure 10: Optocoupler pin-outs IN1 Table 10: Pin Assignment digital Input IN1 Pin Number at Connector X4 Pin Assignment 11 IN1 - 12 IN1 + NOTE: The input is configured for a maximum input voltage of 24 V DC and an input current of max. 20 mA.
OBID i-scan ® UHF Installation ID ISC.LRU1002 4.5. Outputs on connector X4 4.5.1. Digital outputs on connector X4 Optocoupler output: The transistor connections, collector and emitter, of the optocoupler output are galvanically isolated from the Reader electronics and are carried to the outside without any internal ancillary circuitry on Terminal X4. The output must therefore be powered by an external power supply.
OBID i-scan ® UHF Installation ID ISC.LRU1002 Figure 12: Internal and possible external wiring of the optocoupler-outputs OUT1-2 CAUTION: The output is configured for max. 24 V DC / 30 mA. Polarity reversal or overload on the output will destroy it. The output is intended for switching resistive loads only. FEIG ELECTRONIC GmbH Page 17 of 29 M31010-1e-ID-B.
OBID i-scan ® UHF Installation ID ISC.LRU1002 4.5.2. Relay output on connector X4 There is 1 relay output available on connector X4. Figure 13: Relay output pin-outs REL1 Table 12: Pin Assignment Relay Output REL1 Pin Number at Connector X4 Pin Assignment 5 REL1-NO 6 REL1-COM CAUTION: The relay output is configured for max. 24 V DC / 2 A constant load. The switching current must not exceed 1A. The relay output is intended for switching resistive loads only.
OBID i-scan ® UHF Installation ID ISC.LRU1002 5. Operating and Display Elements 5.1. Status LEDs Table 13: Configuration of the LEDs Host Communication Warning ANT 1- 4 RFU RUN Green Yellow Red ON OFF ON Boot sequence (ca.
OBID i-scan ® UHF Installation ID ISC.LRU1002 ANT 1 – 4: Green HF Power switched on Blue Tag-Detect Red Antenna impedance error (> 50Ohm or <50Ohm) 5.2. Reset Push Buttons Figure 15 shows the position of the reset push button T1. At the right side of the connector X4 the push button T1 is positioned. It is located housing.
OBID i-scan ® UHF Installation ID ISC.LRU1002 5.3. Reader Power adjustment To achieve the optimum reading performance it is necessary to set the reader output power to the highest allowed value. This depends on the used reader type (EU / FCC) and the regulation in the country were the reader is used. 5.3.1. EU-Reader according to EN302 208 According to the standard EN302 208 the maximum radiated power is 2 W e.r.p. (Effective Radiated Power) in countries of the European Union.
OBID i-scan ® UHF Installation ID ISC.LRU1002 5.3.2. FCC-Reader according to FCC 47 Part 15 According to the FCC approval, Title 47, Part15 the maximum output power of the reader is limited to 1 W (30dBm). The maximum radiated power of the antenna should not increase more then 4 W e.i.r.p.
OBID i-scan ® UHF Installation ID ISC.LRU1002 6. Technical Data MECHANICAL DATA Housing Aluminum powder-coated Dimension (W x H x D) 261,3 mm x 157,3 mm x 68 mm) 10.29 inch x 6.19 inch x 2.68 inch Weight 1,8 kg (4.0 lb) Protection Class IP 53 (with protection cap IP64) Colour RAL 9003 (Signal White) ELECTRICAL DATA Power Supply 24 V DC ± 5 % (Noise Ripple: max. 150 mV) Power Consumption max.
OBID i-scan ® UHF Installation ID ISC.
OBID i-scan ® UHF Installation ID ISC.LRU1002 APPLICABLE STANDARDS Radio Regulation Europe USA Canada EN 302 208 FCC 47 CFR Part 15 IC RSS-Gen, RSS-210 EMC EN 301 489 Safety Low Voltage Human Exposure FEIG ELECTRONIC GmbH EN 60950 EN 50364 Page 25 of 29 M31010-1e-ID-B.
OBID i-scan ® UHF Installation ID ISC.LRU1002 7. Radio Approvals 7.1. Europe (CE) When properly used this radio equipment conforms to the essential requirements of Article 3 and the other relevant provisions of the R&TTE Directive 1999/5/EC of March 99. Performance Classification according to ETSI EN 301 489: Class 2 FEIG ELECTRONIC GmbH Page 26 of 29 M31010-1e-ID-B.
OBID i-scan ® UHF Installation ID ISC.LRU1002 7.2. Declaration of Conformity (Directive 1999/5/EC - R&TTE) Figure 18: Declaration of Conformity FEIG ELECTRONIC GmbH Page 27 of 29 M31010-1e-ID-B.
OBID i-scan ® UHF Installation ID ISC.LRU1002 7.3. USA (FCC) and Canada (IC) 7.3.1. USA (FCC) and Canada (IC) warning notices Product name: ID ISC.LRU1002-FCC ID ISC.LRU1002-FCC Reader name: ID ISC.LRU1002-FCC ID ISC.LRU1002-FCC FCC ID: IC: Notice for USA and Canada PJMLRU1002 6633A-LRU1002 This device complies with Part 15 of the FCC Rules and with RSS-210 of Industry Canada. Operation is subject to the following two conditions.
OBID i-scan ® UHF Installation ID ISC.LRU1002 7.3.2. Label Information The following information must be placed at the outer side of the housing in which the reader is mounted. Contains FCC ID PJMLRU1002 Contains IC: 6633A-LRU1002 7.3.3. Installation with FCC / IC Approval FCC-/IC-NOTICE: To comply with FCC Part 15 Rules in the United States / with IC Radio Standards in Canada, the system must be professionally installed to ensure compliance with the Part 15 certification / IC certification.