OBID® classic-pro Installation ID CPR.M02/ANT19 ID CPR.M02/ANT19 ID CPR.M02.VP/AB-CA with ID ICS.ANT19 (english) FEIG ELECTRONIC GmbH Page 2 of 20 Manual-M21001-3de-ID-B.
OBID® classic-pro Installation ID CPR.M02/ANT19 Note © Copyright 2002 - 2006 by FEIG ELECTRONIC GmbH Lange Strasse 4 D-35781 Weilburg-Waldhausen Tel.: +49 6471 3109-0 http://www.feig.de Edition: bs/07/10/30 - manual-m21001-3de-id-b.doc With the edition of this manual, all previous editions become void. Indications made in this manual may be changed without previous notice.
OBID® classic-pro Installation ID CPR.M02/ANT19 Contents 1. Safety Instructions / Warning - Read before start-up ! 5 2. Performance Characteristics of the ID CPR.M02 Reader 6 2.1. Performance Characteristics .............................................................................................6 2.2. Available module and antenna types ................................................................................6 2.3. Scope of delivery..........................................................
OBID® classic-pro Installation ID CPR.M02/ANT19 1. Safety Instructions / Warning - Read before start-up ! • The device has to be used only for the purpose designed by the manufacturer. • The operation manual has to be stored available at any time and has to be handed over to each user. • Unauthorized changes and the use of spare parts and additional devices which have not been sold or recommended by the manufacturer may cause fire, electric shocks or injuries.
OBID® classic-pro Installation ID CPR.M02/ANT19 2. Performance Characteristics of the ID CPR.M02 Reader 2.1. Performance Characteristics The ID CPR.M02 Reader Module is designed for reading and writing passive transponders having an operating frequency of 13.56 MHz. It is suitable for any application in which short read ranges and small reader dimensions are required. 2.2. Available module and antenna types The following module types are currently available: Modul Type Power Supply ID CPR.M02.
OBID® classic-pro Installation ID CPR.M02/ANT19 3. Installation and wiring 3.1. Dimensions Fig. 3.1-1 shows the dimensions of the ID CPR.M02 Reader Module 50,0 44,0 V1V2 Ø X4 3,3 X1 ,3 Ø3 C405 44,0 X2 2,1 24,0 3,5 26,1 50,0 J1 C315 X3 Ø3,3 11,5 14,0 Ø3,3 Fig. 3.1-1: Dimensions of the ID CPR.M02 Reader Module FEIG ELECTRONIC GmbH Page 7 of 20 Manual-M21001-3de-ID-B.
OBID® classic-pro Installation ID CPR.M02/ANT19 3.2. Wiring Fig. 3.2-1 and Table 3.2-1 show the pin assignments for Terminal X1. The pin connector is designed for flat cable connection using an IDC multipoint socket connector with 2.54 mm pin spacing. X1 10 9 8 7 6 5 4 3 V1V2 X4 X1 C405 J1 2 1 X2 C315 X3 Fig. 3.2-1: Pin assignments for Terminal X1 Description X1 Pin no.
OBID® classic-pro Installation ID CPR.M02/ANT19 3.2.1. Supply voltage The ID CPR.M02 must be supplied only by a regulated power supply. If switching power supplies are used with the module, be sure that there is adequate filtering. Noise from the power supply can result in a reduction of the read/write range of the module. The cable length from the power supply should be as short as possible, and should in any case not exceed 3 m. Description X1 Pin no.
OBID® classic-pro Installation ID CPR.M02/ANT19 3.2.2. RS232 interface The length of the cable to the RS232 interface should be kept as short as possible, and must in any case not exceed 3 m. X1 Pin no. Description Function 3 4, 9 5 * ** ID CPR.M02 TxD * RS232-TTL - Transmit Data GND ** GND RxD * RS232-TTL - Receive Data Signal names as seen by the Reader Module. GND-Pins 4 and 9 are to be connected directly to each other on the Reader Module Table 3.2.
OBID® classic-pro Installation ID CPR.M02/ANT19 3.2.3. Data/Clock interface The length of the cable to the data/clock interface should be kept as short as possible. It must not exceed 3 m. Description X1 Pin no. Function 1 DAT Data line for the data/clock interface 2 CLK Clock line for the data/clock interface 7 CLS CLS line for the data/clock interface 4, 9 GND * GND * ID CPR.M02 GND-Pins 4 and 9 are to be connected directly to each other on the Reader Module Table 3.2.
OBID® classic-pro Installation ID CPR.M02/ANT19 3.2.4. Connection of an external Antenna (ID ISC.ANT19) The ID CPR.M02.VP/AB-CA are intended for the connection of an external 50Ω-Antenna. The use of the integrated antenna is not possible with this version. Fig. 3.2.4-1 and Table 3.2.4-1 shows the pin assignments for Terminal X2 for the connection of the external antenna. The pin connector has a pin spacing of 2.54mm. V1V2 X4 X1 C405 J1 X2 1 Signal 2 GND } Connector ext.
OBID® classic-pro Installation ID CPR.M02/ANT19 3.2.5. Optional Module ID SAM.M02 If needed, the optional device ID SAM.M02 can be connected to terminals X3 and X4. The ID SAM.M02 is a module for connecting and driving an additional SAM and provides security by using cryptographic data transmission between the reader and transponder. V1 V2 X4 50,0 X1 C315 X3 11,5 10,0 25,0 Fig. 3.2.4-1: Dimensions of ID CPR.M02 with ID SAM.M02 FEIG ELECTRONIC GmbH Page 13 of 20 Manual-M21001-3de-ID-B.
OBID® classic-pro Installation ID CPR.M02/ANT19 3.3. Display elements The ID CPR.M02 Reader Module has a green LED (V1) and a red LED (V2) which are used as display elements (Fig. 3.3-1). V1 V2 X4 X1 J1 Fig. 3.3-1: Position of LEDs V1 and V2 LED Color Standard setting V1 Green • Flashes 4x after a reset. • Flashes continuously at a frequency of 2 Hz. Red • Flashes 4x after a reset. • Comes on for 1 second after successful communication with a transponder. V2 Table 3.
OBID® classic-pro Installation ID CPR.M02/ANT19 3.4. Operating elements 3.4.1. Operating/Programming Mode: Jumper J1 Jumper J1 is used to configure the operating and programming mode of the ID CPR.M02. In standard operation the jumper is set to Position 1-2 (see Fig. 4.3.1-1). The reader is then in normal operating mode. If the jumper is set to Position 2-3, the integrated hardware bootloader starts after a reset.
OBID® classic-pro Installation ID CPR.M02/ANT19 3.4.2. Retuning the internal antenna (ID CPR.M02.VP/AB-C) The antenna of the ID CPR.M02.VP/AB-C can be detuned as a result of various ambient conditions such as nearby metal objects (see Section 8.5). This detuning can be compensated to some degree using the trim capacitor C315. V1V2 X4 X1 Trim capacitor C405: C405 J1 C315 X3 DO NOT CHANGE !!! Trim capacitor C315: Retuning the integrated antenna Fig. 3.4.
OBID® classic-pro Installation ID CPR.M02/ANT19 Use caution when the maximum value of the signal amplitude is reached at the minimum or maximum position of the trim capacitor (Fig. 3.4.3-3). This usually means the antenna is too severely detuned by the surroundings and can no longer be fully compensated by the trim capacitor. Labeling Beschriftung Minimum Minimale Kapazität capacitance Maximum Maximale Kapazität capacitance Fig. 3.4.
OBID® classic-pro Installation ID CPR.M02/ANT19 3.5. Installation notes Be aware of the following possible environmental factors when installing an ID CPR.M02 into another device : • Effects from nearby metal objects ⇒ Detuning of the integrated antenna ⇒ Impaired propagation of the antenna’s magnetic field • EMC effects on cables ⇒ Impaired communication between reader and transponder • EMC effects from magnetic fields ⇒ Impaired communication between reader and transponder 3.5.1.
OBID® classic-pro Installation ID CPR.M02/ANT19 3.5.3. EMC effects from magnetic fields Since in this type of RFID-Technology the communication between the reader and transponder takes place by modulation of a magnetic field, alternating magnetic fields in the vicinity of the antenna can have a negative impact on its function. Sources of such magnetic interference fields include coils within a primary or secondary switching power supply.
OBID® classic-pro Installation ID CPR.M02/ANT19 4. Radio Approvals 4.1. Europe (CE) When used according to regulation, this radio equipment conforms with the basic requirements of Article 3 and the other relevant provisions of the R&TTE Guideline 1999/E6 dated March 99. Equipment Classification according ETSI EN 300 330: Class 2 4.2. USA (FCC) FCC ID PJMCPRM02-ANT19 This device complies with Part 15 of the FCC Rules.
OBID® classic-pro Installation ID CPR.M02/ANT19 5. Technical Data • Dimensions ( W x H x D ) 50 mm x 50 mm x 14 mm • Connector 10 pol. Pin-Connector (grid dim. 2,54 mm) • Supply voltage 5 V DC ± 5% • Power Consumption max. 1,5 W • Operating Frequency 13.56 MHz • RF Transmitting Power 250 mW ± 2 dB • Antenna: ID CPR.M02.VP/AB-CA ripple 0...250 kHz < 10 mVpp ab 250 kHz < 0,1 mVpp External (separate 2 pol. Pin-Connector) • RS232-TTL Interface: ID CPR.M02.VP/AB-C / -CA 4.800 to 230.