Annex no. 5 Functional Description / User Manual Date: 2012-06-11 m. dudde hochfrequenz-technik Vers. no. 1.
INSTALLATION ID CPR46.10 - OBID myAXXESS® flatOne ISO14443-A and -B, NFC Payment Reader preliminary - confidential 2013-01-14 - M20514-4e-ID-B.
OBID® classic-pro Installation ID CPR46.10 Note © Copyright 2012 by FEIG ELECTRONIC GmbH Lange Strasse 4 D-35781 Weilburg Tel.: +49 6471 3109-0 http://www.feig.de With the edition of this document, all previous editions become void. Indications made in this manual may be changed without previous notice. The reproduction, distribution and utilization of this document as well as the communication of its contents to others without express authorization is prohibited.
OBID® classic-pro Installation ID CPR46.10 Contents 1. Safety Instructions / Warning - Read before start-up ! 4 2. Characterization ID CPR46.10 5 2.1. Versions / Ordering Information's ......................................................................................6 2.2. Delivery Content ...................................................................................................................6 2.3. Technical Data ......................................................................
OBID® classic-pro Installation ID CPR46.10 1. Safety Instructions / Warning - Read before start-up ! • The device may only be used for the intended purpose designed by for the manufacturer. • The operation manual should be conveniently kept available at all times for each user. • Unauthorised changes and the use of spare parts and additional devices which have not been sold or recommended by the manufacturer may cause fire, electric shocks or injuries.
OBID® classic-pro Installation ID CPR46.10 2. Characterization ID CPR46.10 The OBID® classic-pro ID CPR46.10 is a transparent EMVCo Level 1 approved contactless RFID card reader for unattended electronic payment-, eTicket- or eMobility- Applications. The reader is explicitly designed to be nearly flat installed into a metallic front panel from the back side like vending machines, ticket machines, petrol- or charging stations, etc.
OBID® classic-pro Installation ID CPR46.10 2.1. Versions / Ordering Information's The ID CPR46.10 reader family includes one model with four SAM Sockets (ID CPR46.10-4SUSB) in ID000 format which are accessible via a service hatch in the rear side of the housing and one model without SAM Sockets (ID CPR46.10-USB). Both models are offering beneath the USB interface a RS232 and a RS232-LVTLL interface. Model ID CPR46.10-4SUSB (OBID myAXXESS® flatOne plus) ID CPR46.
OBID® classic-pro Installation ID CPR46.10 2.3.
OBID® classic-pro Installation ID CPR46.10 • 4 x LED green • 1 x LED red User Interface • 1 x LED yellow • 1 x Buzzer 4 x independent SAM Sockets for ID000 Format (SIM-Card) Contact Interface - ISO7816 (ID CPR46.10-4SUSB only) 9600 to 625.000 bit/s T=0 and T=1 Protocol support of power class A, B, C MTBF 150.000 h CPU / Memory ARM Cortex-M3 at 120 MHz Memory 512 kB Flash-ROM, 128 kB RAM Flash Write Cycles 10.000 Power Consumption – normal Operation Supply Voltage 2 ID CPR46.10-4SUSB ID CPR46.
OBID® classic-pro Installation ID CPR46.10 2.4. Compliance Radio Approval Europe EN 300 330 USA FCC 47 CFR Part 15 Canada IC RSS-Gen, RSS-210 EMC EN 301 489 EN 60950 Safety and Health EN 50364 WEEE - 2002/96/EC Waste and Hazardous Substances RoHS - 2002/95/EC EMVCo FEIG ELECTRONIC GmbH Conform to Book D - EMV Contactless Communication Protocol Specification, Version 2.1 Page 9 of 19 M20514-4e-ID-B.
OBID® classic-pro Installation ID CPR46.10 2.5. Dimensions Fig. 3 ID CPR46.10 dimensions FEIG ELECTRONIC GmbH Page 10 of 19 M20514-4e-ID-B.
OBID® classic-pro Installation ID CPR46.10 3.Mechanical Installation The ID CPR46.10 is intended to be installed into a front panel from the back side like it is shown in Fig. 4 ID CPR46.10 installation. Fig. 4 ID CPR46.10 installation Recommended torque: max. 3,5 Nm If mounted with washer and nut. max. 5,0 Nm If mounted with additional Mounting Frame (see Fig. 8 Recommended Mounting Frame) FEIG ELECTRONIC GmbH Page 11 of 19 M20514-4e-ID-B.
OBID® classic-pro Installation ID CPR46.10 3.1. Recommended Front Panel Cutout Fig. 5 shows the cutout which is recommend for installation of ID CPR46.10 into a front panel. Fig. 5 Recommended front panel cutout for ID CPR46.10 installation FEIG ELECTRONIC GmbH Page 12 of 19 M20514-4e-ID-B.
OBID® classic-pro Installation ID CPR46.10 3.2. Mounting in Metallic and Nonmetallic Front Panels Metallic Front Panels: The ID CPR46.10 is designed to be mounted into metallic front plates. The metallic front panel must have a wall thickness between 2,0 and 5,5 mm. Nonmetallic Front Panels In cases where ID CPR46.10 shall be used in a nonmetallic front plate like plastic or glass a 2 mm steel plate has to mounted between ID CPR46.10 and the non metallic front plate.
OBID® classic-pro Installation ID CPR46.10 3.3. Recommended Mounting Frame In order to achieve a good mechanical resistance against external mechanical influences like vandalism a additional mounting frame is recommended to be placed behind the mounting flange of the ID CPR46.10 as shown in Fig. 8. Fig. 7 Recommended mounting with mounting frame Fig. 8 Recommended Mounting Frame - Dimensions FEIG ELECTRONIC GmbH Page 14 of 19 M20514-4e-ID-B.
OBID® classic-pro Installation ID CPR46.10 4. Wiring and Electrical Connection 4.1. Connection X1, X2 The ID CPR46.10 offers 2 alternative power supply options. Either "Vin" which can be between 8 V DC and 42 V DC or Vcc which can be 5 V DC only. 1 X1 RJ-45 Symbol Function 1 TXD-LVTLL RS232-LVTTL 2 RXD-LVTLL RS232-LVTTL 3 I/O Wakeup 4 Vin 8 V to 42 V DC 5 GND 8 X1 6 Vcc + 5 V DC ± 2 % 7 TxD RS232 8 RxD RS232 X2 Fig.
OBID® classic-pro Installation ID CPR46.10 4.2. Standby / Wakeup The ID CPR46.10 offers a standby mode which can be configured via software commands. If standby is activated the bidirectional Wakeup I/O on X1, Pin 3 is used for signaling a wakeup event by the reader. The Wakeup I/O can be used also by the host activate the ID CPR46.10. To leave the standby mode the reader offers 2 options: 1.
OBID® classic-pro Installation ID CPR46.10 4.3. SAM Socket (ID CPR46.10-4SUSB only) The ID CPR46.10-4SUSB is equipped with 4 SAM sockets which are located behind the latch on the backside of the device. n o p q Fig. 11 ID CPR46.10-4SUSB - SAM socket location and handling FEIG ELECTRONIC GmbH Page 17 of 19 M20514-4e-ID-B.
OBID® classic-pro Installation ID CPR46.10 4.4. LEDs The ID CPR46.10 is equipped with 6 different colored LED (see Fig. 12 ID CPR46.10 - LED position and numbering) which can be controlled by the host separately. LED1 LED2 LED3 LED4 LED5 green yellow LED6 red Fig. 12 ID CPR46.10 - LED position and numbering FEIG ELECTRONIC GmbH Page 18 of 19 M20514-4e-ID-B.
OBID® classic-pro Installation ID CPR46.10 5. Radio Approvals 5.1. Europe (CE) When used according to regulation, this radio equipment conforms with the basic requirements of Article 3 and the other relevant provisions of the R&TTE Guideline 1999/EC dated March 99. Equipment Classification according ETSI EN 300 330: Class 2 5.2. USA (FCC) / Canada (IC) FCC ID PJMCPR46 This device complies with Part 15 of the FCC Rules.