Test report no. 17010672 EUT: ID CPR40 Page 1 of 2 FCC ID : PJMCPR40 FCC Title 47 CFR Part 15 Date of issue: 2017-01-10 Annex acc. to FCC Title 47 CFR Part 15 relating to Feig ELECTRONIC GmbH ID CPR40 Annex no. 5 User Manual Functional Description Title 47 - Telecommunication Part 15 - Radio Frequency Devices Subpart C – Intentional Radiators ANSI C63.4-2014 ANSI C63.10-2013 Date: 2016-08-19 m.
INSTALLATION ID CPR40 ISO14443-A and -B RFID Reader Module Model Order. No. ID CPR40.00-CDUSB 3093.002.00 ID CPR40.01-CDUSB 3222.002.00 ID CPR40.00-CD (3,3 V) 3094.000.00 ID CPR40.01-CD (3,3 V) 3095.002.00 ID CPR40.00-A (RS232) 3096.000.00 ID CPR40.01-A (RS232) 3097.002.
DEUTSCH OBID® classic-pro Montage ID CPR40.
Montage ID CPR40.0x-xx DEUTSCH OBID® classic-pro Hinweis Copyright 2012 by FEIG ELECTRONIC GmbH Lange Straße 4 D-35781 Weilburg Tel.: +49 6471 3109-0 http://www.feig.de Alle früheren Ausgaben verlieren mit dieser Ausgabe ihre Gültigkeit. Die Angaben in diesem Dokument können ohne vorherige Ankündigung geändert werden. Weitergabe sowie Vervielfältigung dieses Dokuments, Verwertung und Mitteilung ihres Inhalts sind nicht gestattet, soweit nicht ausdrücklich zugestanden.
DEUTSCH OBID® classic-pro Montage ID CPR40.0x-xx Inhalt 1. Sicherheits- und Warnhinweise - vor Inbetriebnahme unbedingt lesen 6 2. ID CPR40 Reader Familie 7 2.1. Leistungsmerkmale ........................................................................................................... 7 2.2. Typenübersicht .................................................................................................................. 7 3. Montage und Anschluss 9 3.1. Abmessungen ..............................
Montage ID CPR40.0x-xx 7.2. Type Overview ................................................................................................................. 27 8. Installation and wiring 28 8.1. Dimensions ...................................................................................................................... 28 8.2. Connector X1 - USB ........................................................................................................ 29 8.3. Connector X2 - VCC and Interface...........
DEUTSCH OBID® classic-pro Montage ID CPR40.0x-xx 1. Sicherheits- und Warnhinweise - vor Inbetriebnahme unbedingt lesen Das Gerät darf nur für den vom Hersteller vorgesehenen Zweck verwendet werden. Die Bedienungsanleitung ist zugriffsfähig aufzubewahren und jedem Benutzer auszuhändigen.
Montage ID CPR40.0x-xx 2. ID CPR40 Reader Familie 2.1. Leistungsmerkmale Die Readermodule ID CPR40.0x-xx unterstützen den Datenaustausch (Lesen und Schreiben) mit passiven Transpondern nach ISO14443 Typ A und Typ B, sowie die Kommunikation mit NFC Geräten (ISO18092). Sie sind durch die geringen Abmessungen und die unterschiedlichen verfügbaren Schnittstellen für die eine einfache Integration in Terminals, Gehäuse und andere Geräte konzipiert.
Montage ID CPR40.
Montage ID CPR40.0x-xx Seite 9 von 43 CPR40 - Manual DEUTSCH OBID® classic-pro 3. Montage und Anschluss 3.1.
DEUTSCH OBID® classic-pro Montage ID CPR40.0x-xx Folgende Tabelle zeigt, welcher Typ welche Anschlussstecker aufweist: Reader Type X1 X2 X3a / X3b ID CPR40.00-CD 3.3V - - ID CPR40.01-CD 3.3V - ID CPR40.00-A - - ID CPR40.01-A - ID CPR40.00-CDUSB - ID CPR40.01-CDUSB 3.2. Anschluss X1 - USB Sollen Module mit USB-Interface (ID CPR40.0x-CDUSB) über das USB-Interface betrieben werden, ist die Stecker X1 (“JST PH” RM 2 mm 5pol.
Montage ID CPR40.0x-xx 3.3. Anschluss X2 - VCC & Interface Über die Stiftleiste X2 werden Module für den Betrieb über das RS232, RS232-TTL, RS232-LVTTL oder Data-/Clock Interface angeschlossen. Nachfolgende Abbildung und Tabelle zeigen die Belegung der Stiftleiste X2. Die Stiftleiste ist für den Flachbandkabelanschluss mittels IDC-Federleiste mit Rastermaß 2,54 mm ausgelegt. 2 4 6 8 10 1 3 5 7 9 X2 X2 Pin-Nr. Kurzzeichen ID CPR40.0x-CD 3.3V ID CPR40.0x-A ID CPR40.
DEUTSCH OBID® classic-pro Montage ID CPR40.0x-xx 3.3.1. Spannungsversorgung Versorgungspannung 1 ID CPR40.0x-CD 3.3V ID CPR40.0x-A ID CPR40.0x-CDUSB + 3.3 V DC 5% + 5 V DC 10 % + 5 V DC 10 % Restwelligkeit 0...250 kHz < 10 mVpp ab 250 kHz < 0,1 mVpp HINWEIS: Der Reader darf nur von einer Spannungsversorgung gemäß EN 60950-1 Kapitel 2.5 Stromquellen begrenzter Leistung (LPS) oder mit einen nach NEC Class 2/LPS zertifizierten Netzteil versorgt werden.
Montage ID CPR40.0x-xx 3.3.2. RS232-TTL Interface (ID CPR40.0x-CDUSB) Die Länge des Zuleitungskabels des RS232-TTL Interface sollte möglichst kurz sein. Sie darf 3 m nicht überschreiten. 3.3.3. RS232-LVTTL Interface (ID CPR40.0x-CD 3.3) Die Länge des Zuleitungskabels des RS232- LVTTL Interface sollte möglichst kurz sein. Sie darf 3 m nicht überschreiten. Das RS232-LVTTL Interface kann an einem Host-Interface mit 5 V Pegel betrieben werden. 3.3.4. RS232 Interface (ID CPR40.
DEUTSCH OBID® classic-pro Montage ID CPR40.0x-xx 3.3.6. Anschluss X3 - externe Antenne (ID CPR40.01-xx) Die Module ID CPR40.01-xx sind für den Anschluss einer externen 50 -Antenne vorgesehen. Die Verwendung der internen Antenne ist bei diesen Versionen nicht möglich. Der Anschluss einer externen Antenne kann alternativ über die Stiftleiste X3a oder den koaxial Steckverbinder (U.FL) X3b erfolgen.
Montage ID CPR40.0x-xx 3.3.7. Nachgleich der internen Antenne (ID CPR40.00-xx) Die interne Antenne der Module ID CPR40.00-xx kann durch verschiedene Umgebungseinflüsse wie zum Beispiel Metalle verstimmt werden (siehe Kapitel 3.5). Diese Verstimmung kann in einem gewissen Rahmen durch den Trimmkondensator C1 ausgeglichen werden. Der Nachgleich der internen Antenne kann mit Hilfe eines Oszilloskopes (Bandbreite 20 MHz) durchgeführt werden.
DEUTSCH OBID® classic-pro Montage ID CPR40.0x-xx 3.4. Anzeigeelemente Die Module ID CPR40.0x-xx besitzen eine grüne und eine rote LED als Anzeigeelemente. Nach dem Einschalten oder nach einem Reset blinken beide LED für ca. 2 Sek. gleichzeitig. Im Betrieb signalisieren die LED folgende Betriebszustände: LED - grün blinkt: Reader ist betriebsbereit, hat derzeit aber keine Kommunikation mit dem Host. leuchtet: Polling-Mode: Reader ist betriebsbereit und hat Kommunikation mit dem Host.
Montage ID CPR40.0x-xx DEUTSCH OBID® classic-pro 3.5. Montagehinweise Folgende mögliche Beeinflussungen durch die Umgebung sollten beim Einbau eines ID CPR40.
DEUTSCH OBID® classic-pro Montage ID CPR40.0x-xx 3.5.3. EMV-Beeinflussung über magnetische Felder Das Kommunikationsprinzip von RFID-Technik basiert auf der Modulation eines elektromagnetischen Feldes. Magnetische Wechselfelder in der Nähe der Antenne können sich negativ auf die Funktion des Readers auswirken. Zu den Quellen solcher magnetischen Störfelder gehören zum Beispiel Spulen innerhalb eines primär oder sekundär getakteten Netzteils.
Montage ID CPR40.0x-xx 4. Funkzulassungen 4.1. Europa (CE) Hiermit erklärt FEIG ELECTRONIC GmbH, dass der Funkanlagentyp ID CPR74 der Richtlinie 2014/53/EU entspricht. Der vollständige Text der EU-Konformitätserklärung ist unter der folgenden Internetadresse verfügbar: http://www.feig.de/de/downloads-support/konformitaetserklaerungen.
DEUTSCH OBID® classic-pro Montage ID CPR40.0x-xx 4.2. USA (FCC) und Kanada (IC) FCC ID: PJMCPR40 IC: Notice for USA and Canada 6633A-CPR40 This device complies with Part 15 of the FCC Rules and with RSS-210 of Industry Canada. Operation is subject to the following two conditions. (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Montage ID CPR40.0x-xx DEUTSCH OBID® classic-pro 5. Technisch Daten der Gerätefamilie ID CPR40 Abmessungen ( B x H x T ) 50 mm x 50 mm x 14 mm Gewicht 15 g 3 g Temperaturbereich Betrieb -20°C bis +70°C Lagerung -40°C bis +85°C relative Luftfeuchte 0 bis 95 % nicht kondensierend MTBF 500.000 h Betriebsfrequenz 13.56 MHz Sendeleistung 100 mW 2 dB Antenne: ID CPR40.01-x Interne (48 mm x 48 mm) ID CPR40.
DEUTSCH OBID® classic-pro Montage ID CPR40.0x-xx 5.1. ID CPR40.0x-A Host-Interface RS232 (4.800 bis 230.400 Baud) Anschlussstecker 10 pol. Stiftleiste (RM 2,54 mm) Spannungsversorgung 5 V DC 10 % Restwelligkeit: 0...250 kHz < 10 mVpp ab 250 kHz < 0,1 mVpp Stromaufnahme max. 130 mA 5.2. ID CPR40.0x-CD 3.3V Host-Interface RS232-LVTTL (4.800 bis 230.400 Baud) Data-/Clock (ISO 7811-2, 5 Bit und 7 Bit konfigurierbar) Wiegand Anschlussstecker 10 pol.
Montage ID CPR40.0x-xx 5.3. ID CPR40.0x-CDUSB Host-Interface USB Full-Speed (12 Mbit/s) RS232-TTL (4.800 bis 230.400 Baud) Data-/Clock (ISO 7811-2, 5 Bit und 7 Bit konfigurierbar) Wiegand Anschlussstecker USB: 5 pol. JST PH RS232-TTL, I/O: 10 pol. Stiftleiste (RM 2,54 mm) Spannungsversorgung USB bus powered 5 V DC 10 % Restwelligkeit: 0...250 kHz < 10 mVpp ab 250 kHz < 0,1 mVpp Stromaufnahme max.
OBID® classic-pro Installation ID CPR40.0x-xx ENGLISH Note Copyright 2008 by FEIG ELECTRONIC GmbH Lange Strasse 4 D-35781 Weilburg Tel.: +49 6471 3109-0 http://www.feig.de With the edition of this document, all previous editions become void. Indications made in this manual may be changed without previous notice. Copying of this document, and giving it to others and the use or communication of the contents thereof are forbidden without express authority. Offenders are liable to the payment of damages.
OBID® classic-pro Installation ID CPR40.0x-xx 6. Safety Instructions / Warning - Read before start-up ! 26 7. Performance Characteristics of the ID CPR.M02 Reader 27 7.1. Capability Characteristics .............................................................................................. 27 7.2. Type Overview ................................................................................................................ 27 8. Installation and wiring 28 8.1. Dimensions .........................
OBID® classic-pro Installation ID CPR40.0x-xx ENGLISH 6. Safety Instructions / Warning - Read before start-up ! The device may only be used for the intended purpose designed by for the manufacturer. The operation manual should be conveniently kept available at all times for each user. Unauthorised changes and the use of spare parts and additional devices which have not been sold or recommended by the manufacturer may cause fire, electric shocks or injuries.
OBID® classic-pro Installation ID CPR40.0x-xx 7. Performance Characteristics of the ID CPR.M02 Reader The reader modules ID CPR40 are designed for data exchange (read and write) with passiv transponder according ISO14443 type A and type B and are capable for communication with NFC devices (ISO18092). The small dimensions and the different available interfaces makes them suitable for an easy integration into terminals, housings and other devices.
OBID® classic-pro Installation ID CPR40.0x-xx 8. Installation and wiring ENGLISH 8.1.
OBID® classic-pro Installation ID CPR40.0x-xx Following table shows which reader type is equipped with which connector: X1 X2 X3a / x3b ID CPR40.00-CD 3.3V - - ID CPR40.01-CD 3.3V - ID CPR40.00-A - - ID CPR40.01-A - ID CPR40.00-CDUSB - ID CPR40.01-CDUSB ENGLISH Reader Type 8.2. Connector X1 - USB If modules with USB-Interface (ID CPR40.
OBID® classic-pro Installation ID CPR40.0x-xx 8.3. Connector X2 - VCC and Interface ENGLISH Via the Pin-connector X2 modules with RS232, RS232-TTL, RS232-LVTTL and data/clock interface can be connected for power supply and data exchange. The following figure shows the pin assignments for Terminal X2. The pin connector is designed for flat cable connection using an IDC multipoint socket connector with 2.54 mm pin spacing. X2 Pin-No. Symbol 1 2 * ** *** 2 4 6 8 10 1 3 5 7 9 X2 ID CPR40.
OBID® classic-pro Installation ID CPR40.0x-xx 8.3.1. Power Supply ID CPR40.0x-A ID CPR40.0x-CDUSB + 3.3 V DC 5% + 5 V DC 10 % + 5 V DC 10 % ripple 0...250 kHz < 10 mVpp ab 250 kHz < 0,1 mVpp ENGLISH suppy voltage 2 ID CPR40.0x-CD 3.3V NOTICE: The reader has to supplied by a limited power supply (e.g. NEC Class 2/LPS power supply) according IEC EN 60950, only Use only regulated power supplies. The connection cable should be as short as possible and must be shorter than 3 m.
OBID® classic-pro Installation ID CPR40.0x-xx 8.3.2. RS232-TTL Interface (ID CPR40.0x-CDUSB) ENGLISH The length of the cable to the RS232-TTL interface should be kept as short as possible, and must in any case not exceed 3 m. 8.3.3. RS232-LVTTL Interface (ID CPR40.0x-CD 3.3) The length of the cable to the RS232-LVTTL interface should be kept as short as possible, and must in any case not exceed 3 m. The RS232-LVTTL interface can be used at a host interface with 5 V level. 8.3.4.
OBID® classic-pro Installation ID CPR40.0x-xx 8.3.6. Connector X3 - External Antenna (ID CPR40.01-xx) The modules ID CPR40.01-xx are intended for the connection of an external 50 antenna. The use of the integrated antenna is not possible with this versions. A technical documentation with descriptions for antenna design are available in the application note N20901-#e-ID-B.pdf. 2 X3b 1 X3a X3a Pin-No.
OBID® classic-pro Installation ID CPR40.0x-xx 8.3.7. Integration Instruction and retuning the internal antenna (ID CPR40.00-xx) ENGLISH The antenna of the ID CPR40.00-xx can be detuned as a result of various ambient conditions such as nearby metal objects (see Section 8.5). This detuning can be compensated to some degree using the trim capacitor C1. The integrated antenna can be tuned with the aid of an oscilloscope (bandwidth 20 MHz).
OBID® classic-pro Installation ID CPR40.0x-xx 8.4. Display elements The green and red LED indicating the operating status of the ID CPR40.0x-xx. During operation the LED's indicates the following operating status: LED - green flashing: Reader is ready for operation but communicates currently not with the host permanent: Polling-Mode: Reader is ready for operation and communicates with the host. Scan-Mode: Reader is working in Scan-Mode. LED - red Communication with a Transponder.
OBID® classic-pro Installation ID CPR40.0x-xx 8.5. Installation notes ENGLISH Be aware of the following possible environmental factors when installing an ID CPR40.0x-xx into another device : Effects from nearby metal objects Detuning of the integrated antenna Impaired communication of the antenna’s magnetic field EMC effects on cables Impaired communication between reader and transponder EMC effects from magnetic fields Impaired communication between reader and transponder 8.5.1.
OBID® classic-pro Installation ID CPR40.0x-xx 8.5.3. EMC effects from magnetic fields Sources of such magnetic interference fields include coils within a primary or secondary switching power supply. When determining the position of the reader and antenna within a device, check the device for any possible sources of interference as described above. If necessary, use shielding to suppress such interference.
OBID® classic-pro Installation ID CPR40.0x-xx 9. OEM Instructions ENGLISH 9.1. Information for the OEMs and Integrators The following statement must be included with all versions of this document supplied to an OEM or integrator, but should not be distributed to the end user. This device is intended for OEM integrators only. The transmitter module may not be co-located with any other transmitter or antenna. Please See the full Grant of Equipment document for other restrictions. 9.2.
OBID® classic-pro Installation ID CPR40.0x-xx 10. Radio Approvals Hereby, FEIG ELECTRONIC GmbH declares that the radio equipment type ID CPR74 is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address: http://www.feig.de/en/downloads-support/declarations-of-conformity.html FEIG ELECTRONIC GmbH Page 39 of 43 CPR40 - Manual ENGLISH 10.1.
OBID® classic-pro Installation ID CPR40.0x-xx 10.2. USA (FCC) and Canada (IC) ENGLISH FCC ID: PJMCPR40 IC: Notice for USA and Canada 6633A-CPR40 This device complies with Part 15 of the FCC Rules and with RSS-210 of Industry Canada. Operation is subject to the following two conditions. (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
OBID® classic-pro Installation ID CPR40.0x-xx 11. Technical Data of the Reader Family ID CPR40 Dimension ( W x H x D ) 50 mm x 50 mm x 14 mm Weight 15 g 3 g Operating -20°C to +70°C Storage -40°C to +85°C Humidity 0 to 95 % not condensing MTBF 500.000 h Operating Frequency 13.56 MHz RF Transmitting Power 100 mW 2 dB Antenna ENGLISH Temperature Range ID CPR40.01-x internal (48 mm x 48 mm) ID CPR40.
OBID® classic-pro Installation ID CPR40.0x-xx ENGLISH 11.1. ID CPR40.0x-A Host-Interface RS232 (4800 to 230400 Baud) Connector 10 pol. Pin-Connector (RM 2.54 mm) Supply Voltage 5 V DC 10 % Ripple: 0...250 kHz < 10 mVpp up from 250 kHz < 0,1 mVpp Current consumption max. 130 mA 11.2. ID CPR40.0x-CD 3.3V Host-Interface RS232-LVTTL (4800 bis 230400 Baud) Data-/Clock (ISO 7811-2, 5 Bit und 7 Bit konfigurierbar) Wiegand Connector 10 pol. Pin-Connector (RM 2.54 mm) Supply Voltage 3.
OBID® classic-pro Installation ID CPR40.0x-xx 11.3. ID CPR40.0x-CDUSB Host-Interface USB Full-Speed (12 Mbit/s) Data-/Clock (ISO 7811-2, 5 Bit und 7 Bit konfigurierbar) Wiegand Connector USB: 5 pol. JST PH 10 pol. Pin-Connector (RM 2.54 mm) Supply Voltage USB bus powered 5 V DC 10 % Ripple: 0...250 kHz < 10 mVpp up from 250 kHz < 0,1 mVpp Current consumption max.