FAST & FLUID MANAGEMENT SK550 ENGLISH
Fast & Fluid Management - SK550 p2
Fast & Fluid Management - SK550 Table of Contents SK550 Manual (EN) EU Declaration of Conformity Introduction & warranty Main SK550 components Safety instructions Installation Operation Maintenance Problem solving Error codes Fuses Specifications Electrical wiring diagram Contributing to the Protection of the Environment p3 5 5 6 7 8 9 12 16 17 19 20 21 22 23
Fast & Fluid Management - SK550 p4
Fast & Fluid Management - SK550 SK550 Manual (EN) EU Declaration of Conformity We, Fast & Fluid Management, the Netherlands A Unit of IDEX Corporation Hub van Doorneweg 31 2171 KZ Sassenheim, the Netherlands Declare that: product: Automatic Shaker model: Skandex type: SK550 are in compliance with the following directives: Machinery Directive 2006/42/EC Low Voltage Directive 2006/95/EEC Electromagnetic Compatibility Directive 89/336/EEC according to the following harmonized standards: EN-ISO 12100-1,
Fast & Fluid Management - SK550 Introduction & warranty Introduction By selecting a Fast & Fluid Management shaker you have opted for a product which is the result of intensive research. Top-quality components, craftsmanship and a modern ergonomic design all serve to guarantee a long service life and a high degree of user friendliness.
Fast & Fluid Management - SK550 Main SK550 components 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14.
Fast & Fluid Management - SK550 Safety instructions General safety instructions Attention! Before installing the equipment and setting it in operation, please read the instructions carefully. This is safer both for youself and prevents unnecessary damage to the machine. The manufacturer accepts no liability if the instructions below are not followed: 1. If a machine has been damaged (during transport, for example), do not attempt to set it in operation.
Fast & Fluid Management - SK550 Installation Step 1 - Unpack the machine and unlock the frame lock > Remove box and plastic foil. Note the frame lock bolts on either side of the machine. > Remove both bolts with a size 17 fork wrench. By removing the bolts, the frame lock’s wooden block is released. Be careful not to damage the body and surfaces of your SK550 with any tools while unpacking it.
Fast & Fluid Management - SK550 Please take care to store the frame lock for later use, it is essential for correct transportation. Step 3 - Detach shaker from its transport skid > Pull out cord to remove frame lock’s loose parts. Ensure all loose parts have been removed – two bolts and two wooden blocks. For optimal mixing results and silent operation it is essential to correctly level the machine and lock the adjustable feet.
Fast & Fluid Management - SK550 Step 5 - Electrical connection > Connect the power cable to the socket at the rear of the machine. Ensure the emergency stop is unlocked (turn clockwise). Attention! To prevent damage, the SK550 may only be connected to either 220V/16A/50Hz or 110V/25A/60Hz/50Hz power grids.
Fast & Fluid Management - SK550 Operation A - First time operation Attention! Before operating your SK550 for the first time, please ensure the frame lock was correctly removed (Click here to see) Step 1 - SK550 power management Unlock the emergency stop button on the front of the machine by turning clockwise. The machine is automatically switched on when the power connector at the rear of the shaker is plugged into a 220V or 110V wall socket.
Fast & Fluid Management - SK550 Step 3 - SK550 Control interface Emergency stop for shutting off power completely Program key sequential series of mixing programs Timer keys program start & can clamping Stop & Up program stop & unclamping Various user settings are available in the User Mode menu. B - Operating the SK550 Step 1 - Place can, choose program and start program > Place the container in the can table center, place filler disc and attach hook to container handle. > Close door.
Fast & Fluid Management - SK550 Step 2 - Program ends or is interrupted, remove can > To interrupt the mixing program, press the stop button. Use the emergency stop only in case of calamity. > W hen the program finishes or is interrupted with the stop button, the SK550 will unclamp automatically. Open door and remove container. If your SK550 is fitted with an electric door, it will open automatically. Attention! Only use the emergency stop button in case of a true emergency.
Fast & Fluid Management - SK550 C - User presets for the SK550 Certain SK450 software presets can be adjusted using the interface screen and buttons. To enter the User Mode menu, press the emergency stop button and then unlock it while simultaneously keeping the program button (P) pressed. Upon entering the User Mode menu, a screen will appear showing your SK550 ’s life in mixing cycles and total hours. Press the program button to run through the different user menu’s.
Fast & Fluid Management - SK550 Maintenance Keep your SK550 clean and free of paint residue > Remove all spilt paint from accessible parts (especially clamping plate spindles). Use diluted detergent only and Teflon spray only. Though the SK550 is designed to be completely maintenance free, periodic greasing of moving parts will ensure it remains in top shape. Attention! MOVING PARTS CAN CAUSE INJURY. Always turn off power (e.g. by pressing emergency stop) before accessing moving parts.
Fast & Fluid Management - SK550 Problem solving Introduction Before calling your machine supplier or Service Department, please check whether you can solve the problem yourself. If you cannot, then call the Service Department for advice. Have the model number and serial number at hand (these can be found on the silver CE sticker at the back of the machine). Use the Problem Solving chart below to judge whether you can solve a problem yourself or whether you need to call in the Service Department.
Fast & Fluid Management - SK550 back up again without mixing Container is too weak (crushed) Use stronger container or adjust clamping force Call service Too much mechanical resistance Clean the spindle and lubricate Clamping plate will not go up after mixing Clamping plate is jammed Use interface user setting U4, as explained on 26. If persistent, call service Container unclamps while mixing Container(s) not centered Replace container(s) in gravitational centre.
Fast & Fluid Management - SK550 Error codes Error Cause Action E01 Clamping motor power too low or bad electric wiring Call service E02 Preset minimal clamping pressure not reached Call service E03 Door opened during mixing or door switch defective Keep door closed during mixing.
Fast & Fluid Management - SK550 Fuses Replace fuse at rear of SK550. > Remove mains connector and pull fuse tray outwards. The inner fuse is the (damaged) one to replace, the outer is the spare to replace it with. p20 Dispose of the burnt fuse and in time, remember to get a new spare, type 5x20/T10A (slow). If problem persists, check mains for power surges.
Fast & Fluid Management - SK550 Specifications Maximum product weight 40 kg Timer electronic/programmable Maximum product size (H x W x D) 45 x 35 x 35 cm Minimum product height 7 cm Clamping automatic Clamping pressure variable Product access internal sliding door Shaking speed variable up to 720 rpm Sliding table option Large can table standard Machine size (H x W x D) 116 x 72 x 61 cm Machine weight (empty) 180 kg Available colors available side panels available in all (RAL) col
Fast & Fluid Management - SK550 Electrical wiring diagram p22
Fast & Fluid Management - SK550 Contributing to the Protection of the Environment Packaging Material The packaging protects the machine against damage during transport. The packaging material was chosen based on its limited impact on the environment and its inherent possibilities for waste-disposal. The reuse of packaging material saves raw materials and produces less waste material. Generally speaking, your supplier will take the packaging off your hands.
© Fast & Fluid, 2007 w w w .Fast-Fluid.