User Guide Twisted Pair VTT001 and VTR001 Twisted Pair Transmitter and Receiver 68-760-01 Rev.
Safety Instructions • English Warning This symbol is intended to alert the user of important operating and maintenance (servicing) instructions in the literature provided with the equipment. Power sources • This equipment should be operated only from the power source indicated on the product. This equipment is intended to be used with a main power system with a grounded (neutral) conductor. The third (grounding) pin is a safety feature, do not attempt to bypass or disable it.
FCC Class A Notice This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference. 2. This device must accept any interference received, including interference that may cause undesired operation.
Conventions Used in this Guide In this user guide, the following are used: NOTE: A note draws attention to important information. TIP: A tip provides a suggestion to make working with the application easier. CAUTION: WARNING: A caution indicates a potential hazard to equipment or data. A warning warns of things or actions that might cause injury, death, or other severe consequences.
Contents Introduction............................................................ 1 Features............................................................... 2 Installation............................................................... 3 Rear Panel Connectors......................................... 3 Front Panel Connector and Indicator.................... 6 Cabling and Setup............................................... 7 Compatibilty with Other Extron Products.......... 8 Cable Testing...................
Introduction The Extron® VTT001 twisted pair (TP) transmitter series and VTR001 twisted pair receiver series provide a system for sending VGA, RGBHV, and RGBS signals up to 500 feet (150 meters) over Extron Skew-Free™ A/V UTP cable. They can also send these signals over CAT 5/5e/6 UTP cable. Both transmitter and receiver have remote power capability. For transmission distances up to 300 feet, the applied power is required at either the transmitter or the receiver.
Features • Video sharpness control — Optimizes the video image for different cable lengths between transmitter and receiver. • Removable faceplate — The module faceplate may be removed for tabletop use or attachment to an equipment rack. • Compatibility — The VTR001 receiver series also functions as the receiver for output from the Extron IN1404XT video scaler, Extron TP T 15HD A, TP T 15HD AV, TP T BNC, TP T 15HD 45, TPX 88, TPX 88 A, and TP T BNC DA4.
Installation The Installation section describes: • Rear Panel Connectors • Front Panel Connector and Indicator • Cabling and Setup Rear Panel Connectors VTT001 MAAP VTT001 TX TX VTR001-VTT001 Panel Layout 2 1a 9VDC-12VDC 500mA 9VDC-12VDC 500mA 1a 2a 2b Figure 1. VTT001 MAAP and VTT001 Rear Panel Views NOTE: The VTT001 MAAP and VTT001 models differ in how they are mounted (see Mounting).
Ä Transmitter output connector — A female RJ-45 connector on a 3 inch pigtail for the VTT001 MAAP, or within the VTT001 model. Plug this connector to the UTP cable going to the receiver. CAUTION: Å Receiver input connector — A female RJ-45 connector on a 3 inch pigtail for the VTR001 MAAP and VTR001 AAP models, or within the VTR001 model. Plug this connector to the UTP cable coming from the transmitter. CAUTION: Do not connect the receiver to a computer data or telecommunications network.
CAUTION: NOTE: É Do not tin the stripped power supply leads before inserting them into the captive screw connector. Tinned leads are not as securely attached as untinned leads and could slip out. Both transmitter and receiver have remote power capability. For transmission distances up to 300 feet, the power is required only at either the transmitter Connector wiring.eps or the receiver. Greater distances will require power toPower be applied to both transmitter and receiver.
VTR001-VTT001 Panel Layout 2 Front Panel Connector and Indicator VTT001 MAAP VTT001 3 3 MAAP 1 1 Figure 3. VTT001 MAAP and VTT001 Front Panel Views VTR001 VTR001 MAAP 3 3 MAAP 2 2 VTR001 AAP 3 OUTPUT VTR001 AAP 2 Figure 4. VTR001 MAAP, VTR001, and VTR001 AAP Front Panel Views NOTE: The VTR001 MAAP, VTR001 AAP, and VTR001 models differ in how they are mounted. The AAP version has a larger faceplate than the VTR001 MAAP.
Cabling and Setup To install the VTT001 MAAP and VTT001 models and the VTR001 MAAP, VTR001 AAP, and VTR001 models, follow these steps: 1. Turn all of the equipment off and, if applicable, disconnect it from the power source. 2. Connect the RJ-45 connectors of the transmitter and receiver to either end of the UTP cable (see Cable Testing and Equalizing Pair Skew). NOTE: RJ-45 termination must comply with the TIA/EIA T568A or TIA/EIA T568B wiring standards for all connections, as shown below.
NOTE: If the transmitter or receiver is to be wall-mounted and the power supply will be inaccessible, power must be applied to the power supply before final mounting. Compatibilty with Other Extron Products The VTT001 series and VTR001 series products can communicate with other Extron products. The following tables indicate how the products interact.
Equalizing Pair Skew Pair skew issues are eliminated when you use Extron Skew-Free A/V UTP cables. The manufacturing process for CAT 5e or CAT 6 network UTP cable leads to a condition called pair skew. For best results, pair skew needs to be equalized when using the CAT 5e or CAT 6 cable in A/V applications. The design of Extron’s Skew-Free A/V UTP cable minimizes pair skew to the point that equalization is not required.
Mounting The mountable transmitter (VTT001 MAAP) and mountable receiver (VTR001 MAAP) may be attached to a wall with either a stud-mounted wall box or with a wall mounting bracket (Extron part number: 70-163-xx). Both installations require the double spaced MAAP connector frame, such as the CPM101). The transmitter/receiver module can also be attached to any Extron MAAP device that accepts a double spaced A/V connector panel, or the modules may be rack mounted.
1-gang wall box.eps 6. Insert the wall box or wall bracket into the opening, and attach it to the wall, stud, or furniture, leaving the front edge flush with the outer wall or furniture surface. Wall Stud Installation Cable Wall Stud Installation Cable Cable Clamp Cable Clamp Screws or Nails Screws or Nails Figure 7. Attaching a Wall Box to a Wall Stud • To attach a wall box to wood, use four #8 or #10 screws or 10-penny nails. A minimum of 0.5 inch (1.
Wall box mounting 1. Attach the transmitter/receiver modules to the mounting frame with the included #4-40 screws. 2. Attach all power and video cables to the rear of the transmitter/receiver. Power on the VTT001 install in wall box.eps transmitter/receiver now if the external power supply cannot be accessed once the transmitter/receiver is mounted. 3. Attach the mounting frame (with the attached transmitter/receiver modules) to the wall box, using the two included mounting screws.
Wall bracket mounting VTT001 Wall Mounting w new Bracket.eps 1. Attach the transmitter/receiver modules to the mounting frame with the included #4‑40 screws. 2. Attach all power and video cables to the rear of the transmitter/receiver. Power on the transmitter/receiver now if the external power supply cannot be accessed once the transmitter/receiver is mounted. 3. Attach the mounting frame (with the attached transmitter/receiver modules) to the mounting bracket using the two included mounting screws.
VTT001CM AAP Install.eps AAP mounting The VTR001 AAP version is mounted to the Extron AAP panel by inserting the two AAP studs through the panel mounting holes and attaching the nuts, as shown below. Cable Clamp AAP 102 Cable 2 P 10 AA UT EO VID P INP 01 AA R0 VT VTR001 AAP #4-40 Nut w/ Captive Washer Figure 10.
Rack mounting Various 1U rack space frames accommodate the VTT001 MAAP, VTR001 MAAP, and VTR001 AAP modules. The CPM133 is a one-third rack width frame that can be mounted to the IN9080 rack mount shelf. The CPM112R, as shown below, is a full rack width frame that holds six double sized modules. Depending on the A/V connector frame used, the transmitters/receivers may be mounted to the rack with or without the rack mount shelf. 1.
For mounting the VTT001 MAAP or VTR001 MAAP to a rack mount shelf, mount the transmitter/receiver modules to the A/V connector frame, then attach the frame to the shelf, as shown below. RSB 129 (60-190-01) Rack Mount Shelf CPM133 (60-584-15) or A/V Connector Frame R WE PO r tte mi ns UT CM Tra 01 ir INP T0 Pa EO VT ed VID ist Tw (4) #4 - 40 Screws (4) #6 Screws Figure 12. CPM133 A/V Connector Frame Mounted to a Rack Shelf 2. Attach all power and video cables to the rear of the transmitter/receiver.
#10-32 Screw/ Nylon Captive Cap Washer 1 P 30 AA #4-40 Nut with Captive Washer T AP PU IN 1A 00 VTT VTR001 AAP Twisted Pair Transmitter AAP 301 Architectural Frame Figure 13.
Reference Information Specifications Video Number/signal type ������������������������ 1 set of proprietary analog signals Connectors ������������������������������������ 1 female RJ-45 jack or 1 female RJ-45 jack on a 3" (7.
VTR001 series �������������������������� Input level �������������������������������������� Output level ����������������������������������� Input impedance ���������������������������� Output impedance ������������������������� Max. propagation delay ������������������ Max. rise/fall time ��������������������������� Polarity ������������������������������������������� RGBHV, RGBS 2.0 V to 5.5 Vp-p with ±0.2 VDC offset max. 3.0 V to 4.
Parts List VTT001 MAAP and VTR001 MAAP Description Part Number VTT001 MAAP wall mount transmitter - black 70-284-11 VTT001 MAAP wall mount transmitter - white 70-284-21 VTR001 MAAP wall mount receiver - black 70-285-11 VTR001 MAAP wall mount receiver - white 70-285-21 NOTE: The MAAP models mount into MAAP (mini AAP) panels.
Other Accessories Description Part Number CPM101 MAAP plate, one-gang (black, white) 60-583-11, -21 CPM112R MAAP rack-mount connector panel 60-584-12 CPM133 one-third rack width panel 60-584-15 RSB 129 rack mount shelf 60-190-01 AAP 102 frame (black) 60-300-02 AAP 102 frame (white) 60-300-03 AAP 104 frame (black) 60-301-02 AAP 104 frame (white) 60-301-03 AAP 106 frame (black) 60-531-02 AAP 106 frame (white) 60-531-03 AAP 201 frame - half rack width, 1U (black) 60-302-02 AAP 202 frame
Extron® Warranty Extron Electronics warrants this product against defects in materials and workmanship for a period of three years from the date of purchase.