User’s Guide IPA T RLY4 Relay Accessory Box 68-739-03 Rev.
Introduction Description The Extron IPA T RLY4 Relay Accessory is an IPLink® Accessory product. The Relay Accessory consists of four output relays with normally open (when the relay is de-energized) (NO) and normally closed (NC) contacts. The Relay Accessory converts a solid state (up to 12 VDC) signal, from a source such as the Flex I/O port of an Extron IPL T SF24 or the digital I/O port of an MLC 104 IP Plus, to a relay contact closure.
Connections N The 5-pole captive screw input connector and four 3-pole captive screw output connectors are included with the unit, but you must supply the cable. Extron recommends its CTL Series cable, part #22-148-nn (non-plenum bulk rolls), 26-119-nn (plenum bulk rolls), or 26-461-nn (plenum pre-cut lengths).
Connections N Figure 3 is a wiring diagram of a typical application: an Extron MLC 104 IP Plus controlling an IPA T RLY4 relay function. Refer to the MLC 104 Plus Series Manual for information on configuring the MLC to control the IPA T RLY4.
Connections N Figure 4 is a wiring diagram of a typical application: an Extron IPA T RLY4 driving a screen controller. Please be aware that these are examples only. Your equipment may have different wiring requirments. Refer to the manual from the applicable manufacturer for specific wiring instructions.
Specifications Relay control Relay control ports number/type �� 4 momentary Relay control connectors �������������� (1) 3.5 mm captive screw connectors, 5 pole, for control input and power (4) 3.5 mm captive screw connectors, 3 pole, NO & NC for configurable relay outputs Relay coil operating current �������� 0.015 A (nominal), 0.025 A (maximum). The coil limits the current; no external resistance is required.