User's Manual

Overview of the AP-7602
An AP-7602 is designed for the cost effective deployment of 802.11AC
networks. An AP-7602 supports scalable management options, including
standalone and Virtual Controller (where one AP can manage multiple APs),
WiNG NOC, Site Controllers, and Cloud Management.
AP-7602 Specifications
Telco Box Mounting the AP-7602 Wireless
Wallplate
For telco Box installations, the Wireless Wallplate is installed directly over the
standard wall plate supplying Ethernet. All cabled electrical connections are
made within a recessed well in the housing of the Access Point. To install the
Wireless Wallplate over a telco box:
1 Remove the existing screws and the existing wallplate cover.
2 Gently push RJ-45 outlets into telco box.
3 Reuse the existing screws to screw the mounting plate to the telco box.
4 Without going over any plastic, connect one end of the 10cm RJ-45 cable into GE1 and
route the GE1 cable back through the routing channel on the underside of the Wireless
Wallplate. Plug the other end of the 10cm RJ-45 cable into the RJ-45 outlet.
5 Snap the Wireless Wallplate to the mounting plate and verify the unit has power by
observing the LEDs.
6 The AP-7602 is ready to configure.
Wall Mounting the AP-7602 Wireless Wallplate
An AP-7602 can be mounted to a flush surface without a telco box.
1 Install the included mounting bracket to the wall using wood screws and wall anchors
if appropriate.
2 Connect an Ethernet cable to the GE1 port before connecting the Access Point.
3 Hook the top of the Access Point to the bracket, rotate and snap the bottom of the
Access Point.
4 Optionally install the included security screw once the installation is verified.
5 The Access Point is ready to configure.
Basic AP-7602 Configuration
Once the Access Point is installed and powered on, complete the following
WiNG Assist configuration steps to get up and running with minimal
administrative intervention.
Startup Assist updates existing settings. To delete or revise existing settings,
either rerun Startup Assist or navigate to where those parameters appear in
the user interface and update them accordingly. Refer to the Access Point’s
Wireless
Interface
Dual Radio, 802.11a/b/g/n/AC; 2.4GHz/5GHz
Ethernet
Interface
Two 10/100/1000Mb auto-sensing
Power 802.3af PD on GE1; or 12VDC barrel connector
Operating
Frequency
2.4GHz band: 2400 – 2483 MHz
5GHz band: 5150 - 5350 MHz and 5470 - 5850 MHz
RF TX Power
1dBm to 19dBm in 1dBm increments
Actual power dependent on national standards
Antennas
2 internal dual band antennas supporting 1x1:1 or 2x2:2
2.4GHz: 3.764Bi peak gain
5GHz: 5.95dBi peak gain
Management
Telnet, SSH, HTTP, HTTPS, SNMPv2/v3
Wing Controller, Azara Cloud
more advanced configuration documentation, available on the support site,
for updating the management interface beyond the scope of the WiNG Assist
configuration described in this guide. For more information, see:
www.extremenetworks.com/support.
To define a basic Startup Assist configuration:
1 Power the Access Point using an appropriate power adapter, PoE injector, or PoE
switch.
2 Connect to the Access Point using its default IP address located on the backside of the
Access Point.
3 Enter the default username admin in the Username field.
4 Enter the default password admin123 in the Password field.
5 Select the Login button to load the management interface. If logging in using a factory
default configuration, Startup Assist automatically displays.
Select the Basic screen, click Startup Assist.
Set the following Startup Assist parameters:
Virtual Controller - Sets this Access Point as a Virtual Controller capable of managing
and provisioning up to 24 other Access Points of the same model. Access Points
managed by this Virtual Controller list this Access Point's AP Name as its own. Only
one Virtual Controller can be designated.
Country Name - Set the Access Point's deployment country. Selecting the correct
country is central to legal operation. Each country has its own regulatory restrictions
concerning electromagnetic emissions and the maximum RF signal strength that can
be transmitted.
Note: Country Name can not be changed when deployed in the United States or
Canada.
Timezone - Specify the geographic timezone where the Access Point is deployed.
Different time zones have daylight savings clock adjustments, so specifying the
timezone correctly is important to account for geographic time changes.
Date & Time -Set the date, hour and minute for the current system time in AM or PM
format.
WLAN 1 Name - Provide a unique network identifier name for this WLAN. This is a
required setting. The name is used for the SSID.
Authentication - Select PSK to apply a 64 character maximum passphrase in either
ASCII or Hex format.The authenticating device must use the same PSK algorithm
during authentication. Selecting Show displays the key in exposed plain text (not
recommended).
Selecting Open is not a recommended authentication scheme, as it would provide the
Access Point's WLAN no security via credential exchange and would only make sense
in a network where no sensitive data is either transmitted or received.
6 Select Apply to save and commit the Startup Assist changes to the Access Point's
configuration. Select Discard to revert to the last saved configuration.
Regulatory Information
This guide applies to the following Model Number AP-7602.
Extreme Networks devices are designed to be compliant with rules and
regulations in locations they are sold and will be labeled as required.
Local language translations are available at the following Website:
www.extremenetworks.com/support
Any changes or modifications to Extreme Networks equipment, not expressly
approved by Extreme Networks could void the user's authority to operate the
equipment.
Extreme Networks devices are professionally installed, the Radio Frequency
Output Power will not exceed the maximum allowable limit for the country of
operation.
Antennas: Use only the supplied or an approved replacement antenna.
Unauthorized antennas, modifications, or attachments could cause damage
and may violate regulations.
Bluetooth® Wireless Technology
This is an approved Bluetooth® product. For more information or to view the
End Product Listing, please visit https://www.bluetooth.org/tpg/listings.cfm.
Wireless Device Country Approvals
Regulatory markings subject to certification are applied to the device
signifying the radio(s) is/are approved for use in the following countries and
continents: United States, Canada, Japan, China, South Korea, Australia, and
Europe.
Declaration of Conformity in Languages of the
European Community
Hereby, Extreme Networks, Inc. declares that the radio equipment type
Wireless LAN Access Point is in compliance with Directive 1999/5/EC. The
full text of the EU declaration of conformity is available at the following
Internet address: http://www.extremenetworks.com/
Country Selection
Select only the country in which the device will be used. Any other selection
will make the operation of this device illegal.
Country Roaming
This device incorporates the International Roaming feature (IEEE802.11d)
which will ensure the product operates on the correct channels for the
particular country of use.
Ad-Hoc Operation (2.4 GHz band)
Ad-Hoc operation is limited to Channels 1-11 (2412-2462 MHz).
Frequency of Operation – FCC and IC
5 GHz Only
Industry Canada Statement:
Caution: The device for the band 5150-5250 MHz is only for indoor usage to
reduce potential for harmful interference to co-Channel mobile satellite
systems. High power radars are allocated as primary users (meaning they have
priority) over other frequencies and these could cause interference and/or
damage to LE-LAN devices.
Attention: Le dispositif pour la bande 5150-5250 MHz est uniquement destiné
à une utilisation en intérieur afin de réduire les Pour les brouillages
préjudiciables aux systèmes de satellites mobiles co-canaux. Les radars haute
puissance sont Alloués en tant qu'utilisateurs principaux (c'est-à-dire qu'ils ont
la priorité) par rapport aux autres fréquences et qui pourraient causer des
interférences et / ou endommager les dispositifs LE-LAN.
2.4 GHz Only
Available channels for 802.11bg operation in the US are 1 to 11. The range of
channels is limited by firmware.
Health and Safety Recommendations
Caution: In order to avoid or minimize the potential risk of ergonomic injury
follow the recommendations below. Consult with your local Health & Safety
Manager to ensure that you are adhering to your company's safety programs
to prevent employee injury.
Reduce or eliminate repetitive motion
Maintain a natural position
Reduce or eliminate excessive force
Keep objects that are used frequently within easy reach
Perform tasks at correct heights
Reduce or eliminate vibration
Reduce or eliminate direct pressure
Provide adjustable workstations
Provide adequate clearance
Provide a suitable working environment
Improve work procedures
Wireless devices transmit radio frequency energy and may affect medical
electrical equipment. When installed adjacent to other equipment, verify that
the adjacent equipment is not adversely affected.
Pacemakers
Pacemaker manufacturers recommended that a minimum of 15cm (6 inches)
be maintained between a handheld wireless device and a pacemaker to avoid
potential interference with thepacemaker. These recommendations are
consistent with independent research and recommendations by Wireless
Technology Re search.
Persons with Pacemakers:
Should ALWAYS keep the device more than 15cm (6 inches) from their pacemaker
when turned ON.
Should not carry the device in a breast pocket.
Should use the ear furthest from the pacemaker to minimise the potential for
interference.
If you have any reason to suspect that interference is taking place, turn OFF your
device.
Note: Europe includes, Austria, Belgium, Bulgaria, Czech Republic,
Cyprus, Denmark, Estonia, Finland, France, Germany, Greece,
Hungary, Iceland, Ireland, Italy, Latvia, Liechtenstein, Lithuania,
Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania,
Slovak Republic, Slovenia, Spain, Sweden, Switzerland and the United
Kingdom
Warning: Operation of the device without regulatory approval is
illegal.
Ergonomic Recommendations
Other Medical Devices
Please consult your physician or the manufacturer of the medical device to
determine if the operation of your wireless product may interfere with the
medical device.
RF Exposure Guidelines
Safety Information
Reducing RF Exposure - Use Properly
Only operate the device in accordance with the instructions supplied.
International
The device complies with internationally recognized standards covering
human exposure to electromagnetic fields from radio devices.
Access Points
Access Points must conform to U.S. Federal Communications Commission's
(FCC) limitations. FCC has now stipulated a 21dBm EIRP limit for power
directed 30 degrees above the horizon.
For supplied antennas, compatible with 5.0 GHz on the access points, refer to
the Antenna Guide for "Elevation Gain" information. If using a third-party
antenna, it is required that you obtain the antenna-elevation gain information
from the antenna manufacturer.
Panel antennas and polarized antennas for point to point only are excluded
from this requirement.
The elevation gain must be configured if the access point:
Is used with dipole antenna. and
Is transmitting in the 5.15 - 5.25 GHz Unlicensed National Information Infrastructure-1
(UNII1) band
Power Supply
Use ONLY an approved UL LISTED ITE (IEC/EN 60950-1, LPS/SELV) power
supply with electrical ratings: Output 12Vdc, min 1A, with a maximum ambient
temperature of at least 50 degrees C. Use of alternative power supply will
invalidate any approvals given to this unit and may be dangerous.
Alternately this device may be powered from a 802.3af compliant power
source which has been certified by the appropriate agencies, or by an
approved UL LISTED ITE (IEC/EN 60950-1, LPS/SELV) power supply with
electrical ratings: Output 48Vdc, min 0.25A, with a recommended ambient
temperature greater than 50 degrees C. Use of alternative power supply will
invalidate any approvals given to this unit and may be dangerous.
The product is to be connected to PoE networks without routing to the
outside plant.
Radio Frequency Interference Requirements—FCC
This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to Part 15 of the FCC rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications.
However there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off
and on, the user is encouraged to try to correct the interference by one or
more of the following measures:
Reorient or relocate the receiving antenna
Increase the separation between the equipment and receiver
Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected
Consult the dealer or an experienced radio/TV technician for help.
Radio Transmitters (Part 15)
This device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) this device may not cause harmful interference,
and (2) this device must accept any interference received, including
interference that may cause undesired operation.
The equipment shall be subject to professional engineering personnel to install
and configure, it just can be used, and may not be sold directly to the general
consumer.
Based on 20cm separation distance to assess the amount of electromagnetic
exposure(MPE).
MPE limit 1mW/cm; Test result is 0.39207 mW/cm
When using this device, it is recommended to have a separation distance of 20
cm.
This transmitter must not be co-located or operating in conjunction with any
other antenna or transmitter.
Radio Frequency Interference Requirements - Canada
CAN ICES-3 (B)/NMB-3(B)
Radio Transmitters
This device complies with Industry Canada's licence-exempt RSSs. Operation
is subject to the following two conditions: (1) This device may not cause
interference; and (2) This device must accept any interference, including
interference that may cause undesired operation of the device.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux
appareils radio exempts de licence. L'exploitation est autorisée aux deux
conditions suivantes: (1) l'appareil ne doit pas produire de brouillage, et (2)
l'utilisateur de l'appareil doit accepter tout brouillage radio électrique subi
même si le brouillage est susceptible d'en compromettre le fonctionnement.
Label Marking: The Term 'IC:' before the radio certification only signifies that
Industry Canada technical specifications were met.

Summary of content (2 pages)