ɉ Content ɉ Objectives part 1 4ɉ Terms of use part 2 4ɉ Warranty part 3 5b Components part 4 4.1 CloudCell Gateway 4.2 Outdoor Omnidirectional Antenna 4.3 RF jumper cable 4.4 Lightning protector 4.5 Two Micro SIM cards 4.6 Grounding straps 4.7 Butyl mastic tape 4.8 Clamps and cable ties 4.9 Ethernet cabling 4.10 Recommended equipment 7b 7b 7b 8b 8b 8b 9b 9b 9b 10b 11b Preparing the Gateway and cabling the network part 5 5.1 Connectors specification 5.2 Grounding 5.3 Mount Antenna 5.
Objectives part 1ɉ Theb purposeb ofb thisb documentb isb tob provideb cabling,b installation,b andb bootupb instructionsb ofb ab Everynet gateway in an external or tower environment.b Terms of use ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● part 2ɉ Installer MUST strictly follow installation requirements as conditions of product warranty.
Warrantyɉ part 3ɉ Limited Warrantyɉ Everynet, B.V. (“EVERYNET”) warrants that the product(s) furnished hereunder (the “Product(s)”)b shall be free from defects in material and workmanship for a period of one (1) year from the date ofb shipment by EVERYNET under normal use and operation.
EXPRESS, IMPLIED OR STATUTORY, INCLUDING, BUT NOT LIMITED TO, REPRESENTATIONS,b GUARANTEES, OR WARRANTIES OF MERCHANTABILITY, ACCURACY, QUALITY OF SERVICEb OR RESULTS, AVAILABILITY, SATISFACTORY QUALITY, LACK OF VIRUSES, QUIET ENJOYMENT,b FITNESS FOR A PARTICULAR PURPOSE AND NON INFRINGEMENT AND ANY WARRANTIESb ARISING FROM ANY COURSE OF DEALING, USAGE OR TRADE PRACTICE IN CONNECTIONb WITH SUCH PRODUCTS AND SERVICES.
Componentsɉ part 4ɉ b 4.1 CloudCell Gatewayɉ ● ● ● ● ● ● ● ● ● ● ● 48VDC PoE inputb 15W power consumptionb Triple redundant backhaulb Weatherproof ethernet jackb Externally accessible dual SIM slotb Internal antenna optionb 4 hour internal batteryb Tropical/Equatorial environment operationb High visibility status LEDsb Pre-loaded Everynet Agentb Pre-configured VPN for Everynet RANb b b 4.
4.3 RF jumper cableɉ Please make sure that RF jumper cableb meets these minimum specificationb b ● 50 Ohm N male connectorb ● 50 Ohm LMR240 or LMR400 typeb cableb ● UV protected and weatherproofb ● 1 meter lengthb ● -40 to +85*C temperature rangeb b b 4.4 Lightning protectorɉ Please make sure that lightning protectorb meets these minimum specificationb ● N male on antenna sideb ● N female on equipment sideb ● 0.
4.6 Grounding strapsɉ ɉ ● Cable minimum diameter 2.5b mm2 or 14 AWGb ● Must use termination lugsb ● Grounding bolt on CloudCell isb 5mm diameterb ● Grounding bolt on lightningb protector is 3mmb ● Ground directly to towerb grounding points only using antib oxidation agent and appropriateb lugsb ● Two grounding straps requiredb b b 4.7 Butyl mastic tapeɉɉ ● 3M Butyl Mastic Tape 2212 - 3M IDb 7000133439b b b 4.
Cable tiesb ● 20 cm and 35 cm lengthsb ● UV stabilized Nylon 6/6b ● Weather resistant and continuous exposureb outdoor use ratedb ● 50-pound testb b 4.9 Ethernet cablingɉ Ubiquiti TOUGHcable PRO Carrierb ● Outdoor use CAT5eb ● UV protectedb ● 24 AWGb ● Braided shieldb ● Foil Shieldb ● Ground wireb Grounded ethernet connector (PoE side)b b ● Ubiquiti TC-GNDb Ethernet connector and boot (gateway side)b b ● CONEC 17-10001bb ● Ubiquiti TC-CONb b b b everynet.
PoE adapterb b ● Ubiquiti 48 volt 24 watt PoE injector MPN:b POE-48-24Wb ● Use only 3 pin grounded power cord for PoEb powerb b NOTE: Verify with continuity meter that earthb grounding pin of PoE power cable isb continuous thru the power cord.b b b 4.10 Recommended equipmentɉ ● Wire stripper/cutterb ● 8P8C cable crimping pliersb ● Cutting pliersb b b b everynet.
● Cat5 cable testerb b everynet.
Preparing the Gateway and cabling the network part 5ɉ 5.1 Connectors specificationɉ 1. LoRa radio cableb 2. SIM cards holders + USB + resetb 3. Ethernet cableb b everynet.
5.2 Groundingɉ ⚠Grounding all components is extremely important for protection against lightning strikes and dissipation of static electricity in the cables and equipment. Please see drawing below for grounding diagram. b 5.3 Mount Antennaɉ ● Install the clamps that will attach theb antenna to the towerb b everynet.
● Attach the antenna on the tower tob manufacturer specificationsb b ● Connect one grounding strap to the lightningb protector. Connect the other end to theb grounding point of the tower. Penetrox orb anti-oxidation agent must be used whenb attaching grounding strap to towerb grounding pointb ● Connect lightning arrestor to antennab b b b ● Hand tighten RF cable into the antennab NOTE: Do not use a wrench or pliers as thisb will damage the gateway or connector.
● Completely wrap all RF cable connectionsb and N connectors with 3M Mastic Tape thenb at least two layers of Super 33+ sealing tape.b Two zip tie wraps shall be used for top andb bottom of sealing area (one at top and one atb bottom of connector).b ● Verify weatherproofing on all cableb connectionsb b b b b b b b 5.4 Mount Gatewayɉ Mounting gateway to tower poleb b ● Insert two steel ring clamps through theb gatewayb ● Use metal ties onlyb b b everynet.
● Mount gateway on the tower pole. Tightenb steel ring clampsbb b b b everynet.
● Connect the second grounding strap to theb ground stud on the gateway. Connectb opposite end to the grounding point of theb tower.b b ● Penetrox or anti-oxidation agent must beb used when attaching grounding strap tob tower grounding pointb b IMPORTANT: It is not permitted to ground theb gateway directly to the tower structures.bb b everynet.
5.5 Connect RF jumper cable to the gatewayɉ ● Attach the RF jumper cable to the gatewayb bb IMPORTANT: Do not use a wrench or pliers asb this will damage the gateway and connector.b Tightening of RF connectors must be made byb handb b b b ● Completely wrap all RF cable connectionsb and N connectors with 3M Mastic Tape thenb at least two layers of Super 33+ sealing tape.b Two zip tie wraps shall be used for top andb bottom of sealing area (one at top and one atb bottom of connector).b b b everynet.
● Fix the RF jumper cable in the tower withb cable ties leaving two laps to spare for futureb relocation of the gatewayb b NOTE: Do not bend the RF cable to less than 4b cm radius. Kinking coaxial cable will damageb the cable and cause poor radio performance.b b IMPORTANT: DO NOT use metal zip ties tob secure the cable as it will significantly reduceb the performance and could damage theb gateway. Use only plastic ties.b b b 5.
● Cut the clear plastic around the twisted pairb cable.b ● Use wire cutters to cut off the exposed partb of the plastic.b ● Put the wires in orderb b White-Orangeb b Orangeb b White-Greenb b Blueb b White-Blueb b Greenb b White-Brownb b Brownb b b b ● Place the wires in the correct order, leaveb half the foil to connect the shield to the plug.b ● Insert the wires carefully into the RJ45b connector and press firmly to seat the wiresb into fully into the plug.
● Insert connector into the CONEC housingb and screw nut.b b everynet.
● Plug the network cable into the gateway.bb b b NOTE: Verify CONEC and RJ45 keys areb aligned before insertingb b Check the necessary cable length, alwaysb remembering to leave two laps to spare forb future relocation of the gateway.b b ● Make two laps on the network cable forb leftovers for future relocations.b ● Use plastic cable ties (model 20.32cm) to fixb the cable.b b ● Fix the network cable in the tower with cableb ties (model 35.56cm) every 2 metersb b b b 5.
● Cut the clear plastic around theb twisted pair cable.b ● Use wire cutters to cut off theb exposed part of the plastic.b b b b ● Put the wires in orderb b White-Orangeb b Orangeb b White-Greenb b Blueb b White-Blueb b Greenb b White-Brownb b Brownb b b ● Place the wires in the correct order,b leave half the foil to connect theb shield to the plug.b ● Insert the wires carefully into theb RJ45 connector and press firmly tob seat the wires into fully into the plug.
IMPORTANT: Always verify allb ethernet connections with cable mapb tool and continuity testerb b ● Connect network cable POE port ofb PoE- Ubiquiti PoE 48v-24w injectorb b ● Connect ethernet round wire to theb tower according to the scheme.b ● Connect PoE power cable to 3 pin ACb power jackb b b b everynet.
b b PoE injector MUST have a detachable 3b pin power cord which contains anb integral safety ground wire. Thisb ground pin must be connected to ab grounded safety outlet.b Ethernet cable shield MUST also beb grounded through the AC ground pin ofb the PoE power cable.b 5.8 Verify all the connectors are correctɉ b 5.9 Check LEDs indicationɉ ● Check that the connecting lights are in the correct colors.
5.10 Verify gateway is affixed securely on the towerɉ b everynet.
FCCɉ part 8 FCC Caution: Any changes or modifications not expressly approved by the party responsible forb compliance could void the user's authority to operate this equipment.b This device complies with Part 15 of the FCC Rules. Operation is subject to the following twob conditions:b (1) This device may not cause harmful interference, andb (2) this device must accept any interference received, including interference that may causeb undesired operation.