User's Manual

1
AN135 ON/OFF MODULE
This plug-in On/Off Module is designed to work with our Passive Infrared Detectors
SP103 and Door/Window Detectors SM103, serving as a receiver. The AN135
plug-in On/Off Module is a Z-Wave
TM
enabled device and is fully compatible with
any Z-Wave
TM
enabled network. Z-Wave
TM
enabled devices displaying the
Z-Wave
TM
logo can also be used with it regardless of the manufacturer, and ours
can also be used in other manufacturer’s Z-Wave
TM
enabled networks. Remote
On/Off control of the connected load is possible with other manufacturer’s Wireless
Controller.
Adding to Z-Wave
TM
Network
In the side of the casing, there is an On/Off knob which is used to carry out
inclusion, exclusion or association. Put a Z-Wave
TM
Wireless Controller into
inclusion/exclusion mode, press the knob on the module to complete the
inclusion/exclusion process.
Fig. 1
Installation
1. Plug this On/Off module into a wall outlet near the load to be controlled.
2. Plug the load into the On/Off module. Make sure the load to be controlled
cannot exceed 700 watts.
3. Turn the knob or switch on the load to the ON position.
4. To manually turn ON the AN135 On/Off Module, press and release the On/Off
knob. The red indicator LED will turn ON, and the load plugged into the AN135
On/Off module will also turn ON.
5. To manually turn OFF the AN135 On/Off Module, simply press and release the
On/Off knob. The red indicator LED will turn OFF and the load plugged into the
AN135 On/Off Module will also turn OFF.
6. If Passive Infrared Detector SP103 or Door/Window Detector SM103 has been
removed from the wall by triggering the tamper switch, the Detector (SP103 or
SM103) will send an alarm command (ALARM_REPORT, Alarm Type ==
0x01, Alarm Level == 0x11) to the AN135 On/Off Module, of which red
indicator LED and the load plugged into the AN135 On/Off module will be on
and off intermittently for 10 seconds simultaneously.
Note: When putting Passive Infrared Detector or Door/Window Detector in use,
do not connect the load belongs to motor or electronic transformers, as the
load would be impaired.
Programming
The On/Off knob allows the user
- Turn on or off the load attached
- Include or exclude the module from the Z-Wave
TM
system
- Control other Z-Wave
TM
enabled devices
See the instructions for SP103 Passive Infrared Detector or SM103 Door/Window
Detector.
Troubleshooting
Symptom Cause of Failure Recommendation
The Module not working and
LED off
1. The Module is not
plugged into the
electrical outlet
properly
2. The Module is out of
order
1. Check power connections
2. Don’t open up the Module and
send it for repair.
The Module LED illuminating,
but cannot control the ON/OFF
Switch of the load attached
Check if the load plugged
into the Module has its
own ON/OFF switch
Set the ON/OFF switch of the
load attached to ON
The Module LED illuminating,
but the Detector cannot control
the Module
1. Not carry out
association
2. Frequency interference
1. Carry out association
2. Wait for a while to re-try
Specification

Summary of content (2 pages)