M 153- HDN552- 001 HD CCTV Digital Video Super Night Vision Camera O PE R AT ION MANUAL Thank you for choosing our high quality camera. Before attempting to connect operate this unit, please read and follow these instructions.
CA UTION These servicing instructions are for use by qualified service personnel only. To reduce the risk of electric shock do not perform any servicing other than that contained in the operating instructions unless you are qualified to do so.
CONTENTS 1 . CA UT IONS 2 . I MP OR TANT SAFETY INSTRUCTI O N 3 . F E A T URES 4 . COMP ONENTS 5 . NA ME AND FUNCTION 6 . I NS T A LLATION 7 . DIME NSIONS 8 . S P E C I FICATION 9 .
1. CAUTIONS This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions; 1. This device may not cause harmful interference. 2. This device must accept any interference received, including interference that may cause undesired operation. Note This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules.
1. CAUTIONS Correct Disposal of This Product (Waste Electrical & Electronic Equipment) (Applicable in the European Union and other European countries with separate collection systems) This marking shown on the product or its literature, indicate that it should not be disposed with other household wastes at the end of its working life.
2. IMPORTANT SAFETY INSTRUCTION 1) Read these instructions. 2) Keep these instructions. 3) Heed all warnings. 4) Follow all instructions. 5) Do not use this apparatus near water. 6) Clean only with dry cloth. 7) Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions. 8) Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.
3. FEATURES • High Resolution SONY 1/3” 2.
5. NAME AND FUNCTION ② ⑥ ① ② ③ ④ ⑤ ⑤ ⑦ ⑧ ③ ① ⑤ ④ Su n s h i e l d F i xi ng B o l t Su n s h i e l d M o u n t i n g B racke t Bo d y Ex t e r n a l Z o o m an d F ocu s a d j ustm ent External Zoom and Focus adjustment After adjusting zoom and focus, to prevent water infiltration, firmly tighten the zoom and focus lever.
6. INSTALLATION • MOUNTING POSITION 360° 90° * 1st Axis * 2nd Axis WARNING ! To prevent injury, this apparatus must be securely attached to the floor/wall in accordance with the installation instructions.
6. INSTALLATION • MONITOR CONNECTION DC12V DC 12V POWER SUPPLY DC12V BNC FEMALE VIDEO IN MONITOR RS485 DUAL(DC12V / AC24V) DC 12V POWER SUPPLY or AC 24V POWER SUPPLY DC12V/AC24V BNC FEMALE VIDEO IN MONITOR RS485 When you install the camera, please glue up the end of cable to keep it stable in order to protect the camera from the humidity problems.
7. DIMENSIONS 87 Unit(mm) 145 68 Ø 129 136 265 126 M15XP 1.
8. SPECIFICATION Image Device SONY 1/3” 2.1M Progressive Color CMOS Image Sensor Effective Pixels 1 9 8 4 (H) x 1 1 0 5 (V ) 3 0 f p s Unit cell size 2 . 8 u m (H) x 2 .
9.
9. OSD MENU STRUCTURE Main IMAGE Sub Menu SHARPNESS GAMMA FLIP LENS SHADING DZOOM RESET DATA RETURN PRIVACY SPECIAL HLMASK PATTERN DISPLAY INFO. RESET DATA RETURN COMM. ADJUST SDI FORMAT SDI FPS SYSTEM CVBS FORMAT APPLY SYSTEM INFO.
9. OSD MENU STRUCTURE • Function Description 0. SETUP - EXPOSURE - WHITE BALANCE - WDR/BLC - DNR - DAY & NIGHT - IMAGE - SPECIAL - SYSTEM - Reset Data All : Go sub menu for camera exposure control. : Go sub menu for camera white balance control. : Go sub menu for camera WDR or BLC action. : Control noise reduction setting. : Go sub menu for camera day & night control. : Go sub menu for adjust image functions. : Go sub menu for special feature control. : Go sub menu for system control & information.
9. OSD MENU STRUCTURE - BLC POS-X - BLC POS-Y - BLC SIZ-X - BLC SIZ-Y : Select BLC control zone vertical position. : Select BLC control zone horizontal position. : Select BLC control zone vertical size. : Select BLC control zone horizontal size. 4. DNR: Reduce image’s noise 5. DAY & NIGHT - MODE > AUTO > COLOR > B&W 6. IMAGE - SHARPNESS - GAMMA - FLIP - LENS SHADING - DZOOM 7. SPECIAL - PRIVACY • ZONE NO. • ZONE OP. • X-POS • Y-POS • X-SIZ • Y-SIZ • COLOR • TRANS.
9. OSD MENU STRUCTURE 8. SYSTEM - COMM. ADJUST • CAMERA ID • BAUDRATE • Apply & Exit - SDI FORMAT - SDI FPS - CVBS FORMAT • CVBS OUT > ON, OFF > AUTO • CVBS VIEW > CROP > FULL - APPLY : RS-485 Communication Setting mode. : RS-485 CAM ID Select. : RS-485 Communication Speed Select. : Apply all RS-485 Setting changed at once. Use the Set button to apply. : 1080P / 720P : 30 or 25 fps in 1080p mode. 60 or 50 fps in 720p mode. : NTSC / PAL : Select mode for CVBS out action. : Enable or Disable CVBS out data.