EverPlex 4CQ USER'S MANUAL Freeze Seq EverPlex 4CQ + NEXT P. Real Time Color Quad Processor High Resolution, Broadcast Quality Playback Zoom Function RS232 Remote Control Connect Up To 4 Cameras Ver. 1.
Table of Content Notice.........................................................................................................................1 Important Messages ..................................................................................................2 Introduction...............................................................................................................3 Specification ............................................................................................................
1 Notice This manual is presented to the users of EverPlex 4CQ by EverFocus Electronics Corp. With years of engineering researches, EverFocus has spared no effort to provide the high quality products to the worldwide users. For the policy of continual product improvement, EverFocus reserves the right to make changes to the product specifications and documentation without notice.
2 Important Messages: 1. To prevent fire or shock hazard, do not expose this equipment to the environment of high humidity and dust. So, do not use it in an unprotected outdoor installation or any area classified as a wet area. 2. Installation environment: The temperature should be kept between -10oC ~ +50oC, humidity under 90%. For safety sake, do not disseminate the unit or put it on an unstable base. 3.
3 Introduction EverPlex 4CQ, a real time color Quad and 4 channel auto switcher, is the best choice for multiple monitoring and recording. The superior video quality is achieved by adopting the advance multi-media technology. The picture of Quad display is sharp and clear because Everplex 4CQ is featured with CCIR601 full resolution and 16 million colors. Main Features: Real-time Quad display. High Resolution 720 x 576 (PAL), 720 x 480 (NTSC). 16 million colors.
4 Specification Video input: 4 cameras + 1 VCR inputs Video output: Video output x 2, 1V p-p/75 ohm Title: Up to 6 characters Timer: Built-in real time clock Alarm input: 4 alarm inputs and 1 alarm reset input Alarm output: 2 Alarm Out (1 Normally Open, 1 Normally Closed) Dimension: 239 x 166 x 55 mm Power source: AC 24V or DC 12V Power consumption: 17W max.
5 Chapter I Functional Description Freeze Seq EverPlex 4CQ + NEXT P. Set DEFAULT 1. Front Panel Keypads 1.1 Full Screen Press any key of FULL SCREEN, the picture of the corresponding quadrant will fill the whole screen of the monitor display. Press the same key again, the quad display will come out. 1.2 Quad Display Press the Quad Display, the picture of the quadrant video will fill the whole screen of the monitor display. 1.
6 1.6 Set Press the SET key to set time/date, title on/off, picture, camera titles, switching sequence, switching time period, alarm sensor type, alarm hold time, and the alarm/video loss records displaying. There are 6 pages in the setting mode : Page 1 : Page Page Page Page Set Time and Date. Turn ON/OFF the time, date, title display for Quad or Full screen display. Display the alarm records. Set the brightness, contrast, color, and tint for each camera. Change the title name of each camera.
7 1.6.1 Date, Time setting, and OSD display on/off setting DATE: TIME: 2000-01-01 01:01:01 QUAD SCREEN DATE: QUAD SCREEN TIME: QUAD SCREEN TITLE: ON ON ON FULL SCREEN DATE: FULL SCREEN TIME: FULL SCREEN TITLE: ON ON ON VERSION N.
8 1.6.3 Set the Brightness, Contrast, Color, Tint for each channel Video Display Set Up 1.6.4 BRIGHT: 32 CONTRAST:27 COLOR: 31 TINT: 32 BRIGHT: 32 CONTRAST:27 COLOR: 31 TINT: 32 BRIGHT: 32 CONTRAST:27 COLOR: 31 TINT: 32 BRIGHT: 32 CONTRAST:27 COLOR: 31 TINT: 32 Set the camera titles Camera Title Setup CH1: CH1 CH2: CH3: CH2 CH3 CH4: 1.6.
9 1.6.6 Set alarm parameters Alarm Setting Menu CH 1 2 3 4 SENSOR N.O. N.O. N.O. N.O. ALARM RESET IN : BUZZER : KEY LOCK : ALARM HOLD TIME: N.O. ON OFF 05 SEC CH1 - CH4 to set the sensor input type as 'N.O.' : normally open, closed will invoke alarm 'N.C.' : normally closed, open will invoke alarm 'closed' means to short the alarm signal line to the ground ALARM RESET IN : To set alarm reset input type as 'N.O.' or 'N.C.
10 Chapter II Back Panel Connection AC24V VIDEO INPUT MONITOR VCR IN OUT OUT ALARM I/O DC12V 1. BNC Connectors 1.1 MONITOR Connect this output port to the main monitor. 1.2 VCR OUT Connect this output port to the VIDEO IN of VCR. The quad video output of live video is obtained from this connector. 1.3 VCR IN Connect this input port to the VIDEO OUT of VCR. 1.4 VIDEO INPUT Connect camera video out to this connector by a 75 ohm coaxial cable. 8 1 2.
11 2.1 Alarm out There are two ways to do the alarm out connection: 2.1.1 Normally Open Connection (use pin # 1 and # 9) 2 8 1 RELAY 15 COIL Alarm out 9 EverPlex 4CQ 2.1.
12 2.2 Alarm in and Alarm reset There are 4 alarm sensors in for 4 channels and 1 alarm reset in, all these 5 alarm inputs can be set to Normally Open or Normally Closed by user and the setting menu. ALARM CIRCUIT SENSOR 1 SENSOR 2 SENSOR 3 SENSOR 4 2 8 9 15 ALARM RESET 1 EverPlex 4CQ 2.2.1 ALARM IN There are four alarm inputs for each camera. When any alarm signal happens, the machine will do the following: 1. Switch to the full screen display of this channel. 2.
13 The ALARM IN can be selected as normally open input or normally closed input: Normally Open : (N.O.) Normally Closed : (N.C.) If the alarm input is selected as Normally Open input, then the input is opened normally and shorted to the ground means an alarm happens. If the alarm input is selected as Normally Closed input, then the input is shorted to the ground normally and opened means an alarm happens. 2.2.2 ALARM RESET External alarm reset signal is used to reset the alarm and turn the buzzer off.
14 3.1. The pin assignment of the 9 pin D-SUB connector EverPlex 4CQ PIN # 1 2 3 4 5 6 7 8 9 NAME NOT CONNECTED TXD RXD NOT CONNECTED GROUND NOT CONNECTED NOT CONNECTED NOT CONNECTED NOT CONNECTED HOST PIN # 1 2 3 4 5 6 7 8 9 NAME NOT CONNECTED RXD TXD DTR GROUND DSR RTS CTS NOT CONNECTED 3.2. Transmission Setting The transmission setting in the EverPlex 4CQ is 9600 baud rate, 1 start bit, 1 stop bit and no parity. 3.3.
15 3.4.
EverFocus Electronics Corp. Head Office: 10F-6, No.79 Sec. 1 Shin-Tai Wu Road, Hsi-Chi, Taipei, Taiwan TEL: 886-2-26982334 FAX: 886-2-26982380 Hong Kong Office: Room 0, 10/F., Block 3, Camelpaint Building, 60, Hoi Yuen Road, Kwun Tong, Kowloon, Hong Kong Tel: 852-27589877 Fax: 852-27589056 USA Office: 2445 Huntington Drive, San Marino, CA 91108, U.S.A.