FAQ

Typical Application
Pressure Ranges:
Typical Installations
Jet pumps turn on and off by a device called the pressure switch (included
with all jet pumps). The pressure range indicates when the pump will turn
on and off.
Mainly used for household water supply from a well, driven point, or open
water source. Pumps should be used with Standard or pre-charged
pressure tank.
Tank
Priming tee
and plug
Ejector (pre-assembly)
Pipe
Flexible PVC coupling
and clamps
Check
valve
To household
Check
Valve
Drive
Coupling
Drive
Point
25 ft Max.
10 ft Min.
5 ft Min.
Well
seal
Pipe
Foot
valve
Priming tee
and plug
Priming tee
and plug
Jet Pumps
What additional items do I need?
Will the pumps operate regardless
of the voltage – 115 or 230?
One pipe between water source and pump indicates a Shallow Well
pump, two pipes Deep Well pump.
The pump is factory pre-wired for 230 volts but can be changed to
operate on 115 volts (see owner’s manual).
When replacing an existing pump, look on the existing pumps
identification label for voltage information.
NOTE: Either Schedule 40 or 80 pipe will work in this installation. Be
sure to check your state and local building codes.
NOTICE: In shallow well it is recommended to install or replace the
foot valve, and a combination check valve.
These pumps should always be used with a pressure tank (The larger
the tank, the less the pump will turn on and off. ).
How can I determine which style pump
I am replacing?
1.
2.
3.
Where is an ejector kit mounted on a
Shallow Well Jet Pump?
The ejector kit is mounted onto the nose of the jet pump in front of
the pump impeller.
4.
Frequently Asked Question
Shallow Well Jet Pumps
For Professional Technical Support call 1-844-241-5521
For Professional Technical Support call 1-844-241-5521
Rev. 05/23/17
Page 1
The pump can be installed in a basement, utility room or crawl space, at
the well, or between the well and the house. If installed outside, it should
be protected by a pump house with heat, and not exposed to sun or
moisture.
Additional
items
needed
QTY Internet#
1-1/4 in Foot Valve
1-1/4 in Priming Tee
1 in Female PVC adaptor
1/2 in pressure relief valve
1 1/4 in Coupling (required if using PVC pipe)
1/2 in x 1/2 in Drain valve
4 in Well Seal
1-1/4 in Flexible PVC Coupling
(required is using PVC pipe)
1-1/4 in Check Valve
1 in Discharge Tee
1 in Male Adaptor
10 in Tank Tee (or recommened size based
on tank size)
1/4 in Plug
2 in Pressure gauge 0-100 psi
1-1/4 in Male Adaptor
205618048
100120387
100347423
205149183
100182626
100348481
203811387
205812176
300494432
100055392
206828008
203990025
100344011
205618015
100204497
205962440
203811644
1
1
2
1
1
1
1
1
1
1
1
1
1
1
3
1 1/4 in PVC pipe schedule 80,
or PVC pipe schedule 40
Where Used
Shallow Well Jet Pumps are positioned above ground and can pump
from 0’ to 25’ depth to water.

Summary of content (1 pages)