Operating Instructions Electronic-Key-System for selection of operating mode EKS2 EN
Operating Instructions Electronic-Key-System EKS2 Contents 1. About this document.............................................................................................. 3 1.1. Scope.............................................................................................................................................3 1.2. Target group...................................................................................................................................3 1.3. Key to symbols.....
Operating Instructions Electronic-Key-System EKS2 1. About this document 1.1. Scope These operating instructions apply to all EKS2-C-USB-M-I1S1-B1-… from version V1.0.0. These operating instructions, the supplementary documents and any enclosed data sheet form the complete user information for your device. 1.2.
Operating Instructions Electronic-Key-System EKS2 2. Correct use The device is used in combination with a touch panel or softkeys as part of a higher-level overall system for selection of operating mode. Before the device is used, a risk assessment must be performed on the machine, e.g.
Operating Instructions Electronic-Key-System EKS2 3.
Operating Instructions Electronic-Key-System EKS2 The data structure of selection of operating mode is hierarchically structured for the individual authorization levels, and it changes values accordingly in the individual polling levels.
Operating Instructions Electronic-Key-System EKS2 4. Exclusion of liability and warranty Liability or warranty is ruled out in case of: Ì Incorrect use Ì Failure to comply with the operating instructions and the safety regulations therein Ì Failure to perform the required check for correct function Ì Changes to the device 5. General safety precautions Safe operating mode selectors fulfill personnel protection functions.
Operating Instructions Electronic-Key-System EKS2 7. Smartcards Various smartcards are available for the device. They differ regarding the type and scope of authorization for selection of operating mode MO.
Operating Instructions Electronic-Key-System EKS2 9. Electrical connection 9.1. General notes WARNING Loss of the safety function due to incorrect electrical connection. Ì Ensure that at least four of the safety outputs FO1A to FO1F can be evaluated by a safe control system at all times. Ì Ensure that the safe control system can process 1-of-n signals. Ì Lay the connecting cables with protection to prevent short circuits. Ì Do not lay connecting cables in the immediate vicinity of sources of interference.
Operating Instructions Electronic-Key-System EKS2 9.3. Terminal assignment Connection terminal FO1F - FO1E MO Service FO1D MO4 FO1C MO3 FO1B MO2 FO1A MO1 0V Ground 0 V UB Operating voltage 24 V DC USB interface The device is connected to the touch panel using the permanently mounted USB cable. 10.
Operating Instructions Electronic-Key-System EKS2 12. Status and fault displays The card holder’s LED illumination indicates the individual status and error messages. Detailed error messages can be output on the touch panel. LED not illuminated LED illuminated 5 Hz Key to symbols LED flashes at 5 Hz 3x LED repeatedly flashes three times 12.1. Status code LEDs flash alternately Smartcard status and fault displays ENUM in .
ENUM in .
Operating Instructions Electronic-Key-System EKS2 12.3. Firmware status display LED indicator green Meaning red Firmware update See “Normal operation” 5 Hz Firmware data are sent to the device during normal operation. The firmware update is activated via a separate command. The firmware update was successful. Acknowledge flashing code by restart or separate command. Restore factory settings The device has been reset to the factory settings. A restart is required.
Operating Instructions Electronic-Key-System EKS2 13. Technical data 13.1. Technical data for EKS2 Parameter Value min. typ. Unit max. General Material Polyamide PA66 Installation orientation Degree of protection On side in the installed state IP54 at front, IP20 in panel Safety class Degree of contamination Mechanical life Ambient temperature at UB = 24 V -25 - +55 °C Storage temperature Reader EKS -45 - +85 °C Smartcard -45 - +55 °C Weight Approx. 0.
Operating Instructions Electronic-Key-System EKS2 13.2. Radio frequency approvals FCC ID: 2AJ58-14 IC: 22052-14 FCC/IC-Requirements This device complies with part 15 of the FCC Rules and with Industry Canada’s licence-exempt RSSs. Operation is subject to the following two conditions: 1) This device may not cause harmful interference, and 2) this device must accept any interference received, including interference that may cause undesired operation.
Operating Instructions Electronic-Key-System EKS2 13.3. Dimension drawing for EKS2… 8 62 74 3,5 X2 Z X1 500 66 92 73 19 16 3,5 Socket strip Z2:1 82 84 16 32 ca.
Operating Instructions Electronic-Key-System EKS2 14. Inspection and service Regular inspection of the following is necessary to ensure trouble-free long-term operation: Ì Check the secure mounting of the devices and the connections Ì Check for contamination No servicing is required. Repairs to the device are only allowed to be made by the manufacturer. NOTICE The year of manufacture can be seen in the lower right corner of the type label. The current version number in the format (V X.X.
Euchner GmbH + Co. KG Kohlhammerstraße 16 70771 Leinfelden-Echterdingen info@euchner.de www.euchner.com Edition: 2546099-01-10/21 Title: Operating Instructions Electronic-Key-System EKS2 (translation of the original operating instructions) Copyright: © EUCHNER GmbH + Co. KG, 10/2021 Subject to technical modifications; no responsibility is accepted for the accuracy of this information.