ETA-ECM30 30A AC Power Module Spike Suppressor ETA-ECM30 30A AC Power Module Spike Suppressor 1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A. Telephone: 800-321-6699 • Fax: 800-996-3821 – 1 – Specifications are subject to change without notice. ETAsys.
ETA-ECM30 30A AC Power Module Spike Suppressor TABLE OF CONTENTS Important Safety Instructions................................................................................................................... 3 Introduction ............................................................................................................................................ 5 Key Features............................................................................................................................
ETA-ECM30 30A AC Power Module Spike Suppressor IMPORTANT SAFETY INSTRUCTIONS The lightning flash with arrowhead symbol within an equilateral triangle, is intended to alert the user to the presence of uninsulated “dangerous voltage “ within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.
ETA-ECM30 30A AC Power Module Spike Suppressor • • • • • • • • • • • • • • • • • • • WARNING – WHEN THE DEVICE IS IN USE To prevent electric shock, do not remove the product cover as there are high voltage components inside. Refer all servicing to ETA Systems. Should any of the following irregularities occur during use, immediately switch off the power, disconnect the power cord from the AC outlet and contact ETA Systems.
ETA-ECM30 30A AC Power Module Spike Suppressor INTRODUCTION Thank you for purchasing the ETA Systems ETA-ECM30 AC Power Module Spike Suppressor Unit. Note: For your safety, all electrical wiring should be done by a qualified electrician. The ETA Systems ETA-ECM30 is an Electrical Control Module (ECM) 30A AC Spike Suppressor that is designed to be used as a stand-alone unit or in conjunction with an ETA-ECS6RM Controller up to 1000ft away.
ETA-ECM30 30A AC Power Module Spike Suppressor FRONT PANEL FEATURES 3 4 5 A B D C E 1 2 6 1. Trigger/Status Port Pin Identification All signals are of low voltage and current. DO NOT MISS WIRE or damage may occur. A. (+) requires a minimum of 5–24V DC to activate the module with 5mA of current. Note: The DCV can be supplied from any source. The EVS protection requires the ETA-ECS6RM for operation. B. G = Circuit Ground. Must be of the same circuit as the DCV source. C.
ETA-ECM30 30A AC Power Module Spike Suppressor ECM HOUSING TYPES ECM-RACEWY3 ECM-RACEWY1 ECM-RACEWY3 ECM-RACEWY1 ECM-RACEWY6 The ETA-ECM30 requires an electrical housing. These housings are manufactured by Atlas Sound and are available through ETA Systems. The ECM-RACEWY1 holds 1 ECM module, the ECM-RACEWY3 holds up to three ECM modules, and the ECM-RACEWY6 holds up to six ECM modules.
ETA-ECM30 30A AC Power Module Spike Suppressor ECM MODULE ACTIVATION WITHOUT USING AN ETA-ECS6RM CONTROLLER Any of the ECM Modules can be triggered remotely to activate without using an ECS type Controller. If you do not need the features of the ECS controllers, remote activation can be accomplished by applying DC external voltage or by hard switch contacts. Note: The EVS and Voltage monitoring will be disabled when not using an ECS controller.
ETA-ECM30 30A AC Power Module Spike Suppressor WIRING THE ETA-ECM30 CONTROL MODULE The ETA-ECM30 is designed to be inserted in the ECM-RACEWY1, ECM-RACEWY3, or ECM-RACEWY6 housing. The specific job (install) AC power requirements and power distribution layout will dictate how the ECM modules are wired into the housing. The ETA-ECM30 Module can be wired as a single 30A run or in a parallel (loop thru) configuration.
ETA-ECM30 30A AC Power Module Spike Suppressor ETA-ECM30 SPECIFICATIONS Type AC Power Module Spike Suppressor RoHS Compliant Yes Safety Listings ETL (UL 60065 Standard) Front Panel Outlet Single 30A, L5-30 Indicators Active (Green), Fault (Red), Incoming AC (Red) External Trigger/Manual On Slide Switch Connectors 5 Position Phoenix Euro Block Style Hard Switch Remote Trigger SPST Contact Status Signals Output for Voltage (When used with ECM-6RM) AC Mains Interconnect Screw Term
ETA-ECM30 30A AC Power Module Spike Suppressor NOTES: 1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A. Telephone: 800-321-6699 • Fax: 800-996-3821 – 11 – ETAsys.com Specifications are subject to change without notice.
ETA-ECM30 30A AC Power Module Spike Suppressor LIMITED WARRANTY All products manufactured by ETA Systems are warranted to the original dealer/installer, industrial or commercial purchaser to be free from defects in material and workmanship and to be in compliance with our published specifications, if any. This warranty shall extend from the date of purchase for a period of one year. Additionally, fuses and lamps carry no warranty.