Table of Contents Table of Contents 1. 2. 3. Product Description................................................................................................................................ 3 Installing the Keypad ............................................................................................................................. 4 Arming and Disarming ............................................................................................................................ 7 3.1. Arming .....
Product Description 1. Product Description The TR-KPD (keypad) is an encrypted, battery operated, wireless, access control and system arming device.
Installing the Keypad 2. Installing the Keypad Ensure that you have: Four AA batteries A screw and wall anchor Screwdriver Drill To install the keypad: 1. Choose a smooth, flat indoor wall near the door. 2. Release the keypad's mounting base by lifting the tab and sliding the base in the tab’s direction.
Installing the Keypad 3. Press the tamper switch several times. Tamper switch 4. Insert four fresh new AA alkaline batteries, according to the correct polarity. WARNING! A new battery can explode if it is incorrectly installed. 5. Drill a hole in the wall and insert a wall anchor. 6. Clean and dry the wall.
Installing the Keypad 7. Peel off the mounting-tape protective strips. 8. Ensure that the wall anchor and tamper pin holes are aligned. Tamper pin hole 9. Press the wall mount into place. 10. Insert a screw in the tamper pin hole and tighten. 11. Align the keypad onto the mounting base, and slide the keypad into place.
Arming and Disarming 3. Arming and Disarming You can use the keypad to activate the following arming modes: Armed Away - Arms all devices Armed Partial- Arms a specified group of devices Armed Perimeter - Arms perimeter devices Disarmed 3.1. Arming Arm Away Arm Partial 2 Arm Perimeter Arm Partial 1 To arm: 1. Press the button for the arming mode you want. 2. If your installation requires authentication for arming, enter your numeric passcode or place your tag over the .
Arming and Disarming 3.3. Checking Arming Status To check the system's arming status, press If . lights green, the system is disarmed. If that light indicate the arming mode. light red, the system is armed. The button or buttons 3.4. Triggering a Panic Alarm In case of an emergency, you can trigger a panic alarm. To trigger a panic alarm, press and hold the keypad's SOS button for at least five seconds.
Changing the Batteries 4. Changing the Batteries To change the keypad's batteries: 1. Release the keypad's mounting base by lifting the tab and sliding the keypad away from the tab. 2. Remove the old batteries. 3. Press the tamper switch several times. Tamper switch 4. Insert four new fresh AA alkaline batteries, according to the correct polarity. WARNING! A new battery can explode if it is incorrectly installed. 5. Align the keypad onto the mounting base, and slide the keypad into place.
Specifications 5. Specifications Item Data Part Number ES700TRKPD Communications Bi-directional protocol: ECOP – Essence proprietary communication protocol Maximum RF range: Up to 700m (2,296 ft.) – open air Modulation and frequency: Europe: 868.3 MHz 2FSK The Americas: 916.5 MHz 2FSK RFID 106 kbps, 13.
Specifications Item Compliance Pending Data EMC and Radio EN 300 220-1: V3.1.1 EN 300 220-2: V3.1.1 EN 300 330: V2.1.1 EN 301 489-1 v 1.9.2 EN 301 489-3 v 1.6.
Specifications NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
Keypad Indications and Actions Keypad Indications and Actions Appendix A Arm Away Arm Partial 2 Information/Status Arm Perimeter Arm Partial 1 The following table describes the keypad's indications and actions.
Keypad Indications and Actions Indication Action/Status Attempt to arm with no devices associated with arming profile Sound One long beep Entry delay countdown Flashes red for two seconds Orange clockwise Disarm Success Three short Lights beeps green for two seconds Disarm Failure One long beep Attempt to disarm when already disarmed Three short Lights beeps green for two seconds Panic Success Three short Red beeps clockwise for 30 seconds Blinks red for two seconds Panic - Failure One long
Keypad Indications and Actions Indication Action/Status Sound Press informationArmed Away Lights red for two seconds Press informationArmed Partial 2 Lights red for two seconds Press informationArmed Partial 1 Lights red for two seconds Press information Armed Perimeter Lights red for two seconds Press informationAlarm in memory Red clockwise for two seconds Press keys when the keypad is locked One long beep Tag Learn Success Three short Lights beeps green for two seconds Tag Learn Failure
Legal Notice Legal Notice Usage of this document, and all information (including product information) provided within, are subject to the following terms and conditions, and all applicable laws. If you do not agree with these terms, please do not access or use the remainder of this document. This document contains highly confidential information, which is proprietary to Essence Security International (E.S.I.) Ltd. and/or its affiliates (hereafter, "Essence").
Legal Notice Smart Security TR-KPD User Guide 17