FBTEST Reference Manual Contents 1 Introduction ................................................................................................. 3 1.1 Field of Application ......................................................................... 3 1.2 Date and Time Window ................................................................... 4 1.3 FBTEST Menu Overview ................................................................ 5 2 Installation Procedures ..................................................
BRU3 MANUAL 6.2 6.3 6.4 6.5 6.6 6.7 Set Time ..........................................................................................29 Radio Operations ............................................................................30 6.3.1 Radio Control and Calibration Menu ..................................30 6.3.2 Transceiver Setup Menu......................................................32 Measurement Setup Menu ..............................................................37 6.4.
FBTEST REFERENCE MANUAL 1 3 (102) Introduction FBTEST is a test program for the Base Radio Unit 3 - BRU3. Two types of user interfaces are available through a serial communication port. One by a menuoriented structure where test alternatives and parameters are selected by stepping through the menus. The other interface is by command frame input, suitable for automatic testing with computer supervision over a communication line. In this case, the command frame syntax is the user interface.
(102) BRU3 MANUAL The information applicable when commissioning shall take place is described in the following sections: • Set System Clock Menu • Radio Control and Calibration Menu, alternatives 1-3 • Status Overview Menu • Modem Operation Menu • Edit Loader Parameters Menu 1.2 Date and Time Window The date and time window in the upper right-hand corner shows the system clock, marked with SYS:. BRU3 MANUAL, Doc.
FBTEST REFERENCE MANUAL 1.
(102) BRU3 MANUAL --------Measurement Setup Menu -------------Select Transmitter ON/OFF -------------Save Test Data at Stop -------------Set Test Time --------Transceiver Control and Presentation Menu -------------Select Transmitter ON/OFF -------------Select Modulation ON/OFF -------------Save Test Data at Stop -------------Set Test Time -------------Start -------------Look at previous data --------Radio Calibration Menu -------------Bandgap Calibration Menu ------------------Increment ----------------
FBTEST REFERENCE MANUAL -------------PR Reflected Power Calibration Menu ------------------Select TX Power Ind. P1-P8 for Offs./Abs.Mode ------------------Enter Temp. Index T1-T5 for Offset/Abs. Mode ------------------Read and enter Calibr. Value for Offset Mode ------------------Mark for Storage in EEPROM ------------------Select Transmitter ON/OFF ------------------Slot Number ------------------Attenuation -------------VCO Modulation Calibration Menu ------------------Enter Temp.
(102) BRU3 MANUAL -------------Setup Radio Operation Parameters -------------PA Bias and FDAC Calibration Menu ------------------PA Bias Driver ------------------PA Bias Final ------------------FDAC Rx ------------------FDAC Tx ------------------Setup Radio Operation Parameters ------------------Set Transmitter On/Off --------Radio Register Editor Menu -------------Read Radio Register -------------Write Radio Register --------Adjustment Menu -------------OCXO Age Adjustment Menu ------------------Increm
FBTEST REFERENCE MANUAL -------------Modem Parameter Menu ------------------Modem in use ------------------Control Type ------------------Prompt ------------------Bit rate ------------------Dial Timeout ------------------Answer Timeout ------------------Init Commands Menu ----------------- Dial Commands Menu -------------X.25 Parameters Menu --------Channels Menu -------------X.
(102) 2 BRU3 MANUAL Installation Procedures Load FBTEST by using ZMODEM during the procedure of installing the BRU3 software. For details, refer to SW Commissioning Procedure in the Software Commissioning Procedure section of the Node SW - Installation and Commissioning module. BRU3 MANUAL, Doc.
FBTEST REFERENCE MANUAL 3 11 (102) Hardware, Equipment and Preparation The preparation work necessary for testing a node is kept at a minimum. A console terminal has to be attached to the Console Connector on the BRU3, and if a test that requires external hardware is to be executed, special test cables are to be connected. 3.1 Configuration All terminal inputs and outputs are directed to the console. The console should be a VT100 terminal or the equivalent.
(102) 3.2 BRU3 MANUAL External Tests requiring External Hardware Some of the external tests require external hardware. The external tests in question are: • Loopback Test of FNB Board • RFTL Test of FRB Board • Modem Tests A Loopback test is carried out of the FNB Board by using a 25 pin D-Sub plug. One of the physical ports is selected according to strapping alternative RS232 or RS422. An RFTL test is carried out of the FRB Board by using an external radio instrument.
FBTEST REFERENCE MANUAL 4 13 (102) FBTEST User Modes FBTEST can be executed in two different user modes. One mode is implemented with menus while the other mode involves the use of a command frame protocol. The menu mode is interactive and the selected test is executed after set up of its parameters. The command frame mode is designed to allow control of execution from an external computer. BRU3 MANUAL, Doc.
(102) 5 BRU3 MANUAL User Interface Description This section describes all the menus that are used in the FBTEST. When the FBTEST program is loaded and started, the Main Menu is displayed on the console terminal. The program is then ready to accept commands. 5.1 Working with Menus The user interface is quite straight-forward but the following must be noted: • To choose a menu alternative: Write the corresponding number and press .
FBTEST REFERENCE MANUAL 5.1.2 15 (102) Menu Displays For the various menu examples shown in this document the respective “paths”, i.e., the hierarchic structure is indicated, to facilitate the selection of the desired menus. See the example below: [Main menu, Radio Operations, Calibration] BRU3 MANUAL, Doc.
(102) 6 BRU3 MANUAL Main Menu When the FBTEST program is started, the Main Menu is displayed on the screen, see Figure 1 “Main menu.”. Depending on selected alternative, different submenus will be displayed, as described below the figure. [Main menu] Figure 1 Main menu. BRU3 MANUAL, Doc.
FBTEST REFERENCE MANUAL 17 (102) The selected alternative will display other menus as follows: Alt. 1 BOARD TEST Displays the Board Test menu, Figure 2. Alt. 2 SET TIME Displays the Set System Clock menu, Figure 11. Alt. 3 RADIO OPERATIONS Displays the Radio Control and Calibration menu, Figure 12. Alt. 4 MODEM OPERATIONS Displays the Modem Operation menu, Figure 41. Alt. 5 STATUS OVERVIEW Displays the Status Overview menu, Figure 42. Alt.
(102) 6.1 BRU3 MANUAL Board Test Menu This menu is shown if alternative 1, “Board Test”, is selected in the Main Menu. From this menu, all tests can be configured and executed. The batch test sequence for each board type is chosen from the different board type menus, and so are all the interactive tests. Figure 2 “Board Test menu.” shows the Board Test Menu.
FBTEST REFERENCE MANUAL 6.1.1 19 (102) Alt. 1: Do the Test This alternative starts the batch test which will execute all selected tests on all selected boards. The tests is defined by: • number of cycles • type of board test mode (extended, medium userdefined) • selected boards • selected tests for each board 6.1.2 Alt. 2: Number of Test Cycles This alternative will display the question “Number of cycles”: (1). Accordingly, the default value is 1.
(102) 6.1.3 BRU3 MANUAL Alt. 3: Select/Unselect Boards Displays a submenu, where all boards can be selected or unselected, and included in or excluded from the test by using the toggle function. Figure 3 “Example of select/unselect menu.” gives an example of this menu. [Main menu, Board Test, Select/Unselect Boards] Select/unselect boards SYS:yyyy-mm-dd hh:mm Current test selection is MEDIUM Board type FCB FRB FNB FMB FPB 1 2 3 4 5 + + + + + 0.
FBTEST REFERENCE MANUAL 6.1.4 21 (102) Alt. 4: Select Extended Test The extended test is a quick-choice alternative to turn on all possible, not interactive tests, for those boards that are selected. External hardware is needed for certain tests. 6.1.5 Alt. 5: Select Medium Test The medium test is a quick-choice alternative to activate tests for selected boards, which do not require interactive operator involvement or external hardware. 6.1.6 Alt.
(102) BRU3 MANUAL 6.1.8 Alt.7: Set Parameters for FCB – FE Computer Board [Main menu, Board Test, Set test parameters for FCB] Test for FCB Current test selection is MEDIUM 1 2 3 4 5 6 7 8 9 + + + + - 0. SYS:yyyy-mm-dd hh:mm DRAM test Exhaustive DRAM test DPRAM test Signal Processor test Communication IC Internal test FLASH Boot Memory test FLASH System Memory test Alarm test Ethernet Module test Test menu Choose alternative: Figure 4 Test for FCB – FE Computer Board. Alt.
FBTEST REFERENCE MANUAL 6.1.9 23 (102) Alt. 8: Set Parameters for FRB – FE Radio Board [Main menu, Board Test, Set test parameters for FRB] Test for FRB SYS:yyyy-mm-dd hh:mm Current test selection is MEDIUM 1 2 3 0. + + - Alarm test EEprom test Radio Loopback test Test menu Choose alternative: Figure 5 Test for FRB – FE Radio Board. Alt. 1 - 3 A toggle function between “+” (select) and ”-” (unselect), is used to select the type of tests that should be performed.
(102) BRU3 MANUAL 6.1.10 Alt. 9: Set Parameters for FNB – FE Connection Board [Main menu, Board Test, Set test parameters for FNB] Test for FNB SYS:yyyy-mm-dd hh:mm Current test selection is MEDIUM 1 2 0. - Serial Loopback - RS232 or RS422 Alarm Interface test Test menu Choose alternative: Figure 6 Test for FNB – FE Connection Board. Alt. 1 - 2 A toggle function between “+” (select) and ”-” (unselect), used to include or exclude boards from the test.
FBTEST REFERENCE MANUAL 6.1.11 25 (102) Alt. 10: Set Parameters for FMB – FE Modem Board [Main menu, Board Test, Set test parameters for FMB] Test for FMB SYS:yyyy-mm-dd hh:mm Current test selection is MEDIUM 1 2 3 0. - Internal Modem test Local Loopback test Remote Loopback test Test menu Choose alternative: Figure 7 Test for FMBF – FE Modem Board. Alt. 1 - 3 A toggle function between “+” (select) and ”-” (unselect), is used to include or exclude boards from the test.
(102) BRU3 MANUAL 6.1.12 Alt. 11: Set Params for FPB – FE Power Supply Board [Main menu, Board Test, Set test parameters for FPB] Test for FPB SYS:yyyy-mm-dd hh:mm Current test selection is MEDIUM 1 0. - Alarm test Test menu Choose alternative: Figure 8 Alt. 1 Test for FPB – FE Power Supply Board. A toggle function between “+” (select) and ”-”(unselect). Note! “ + ” = select “ - “ = unselect BRU3 MANUAL, Doc.
FBTEST REFERENCE MANUAL 6.1.13 27 (102) Alt.12: Look at Test Results When the batch tests are started, the Test Status is shown. It tells you how many faults have been detected for each board, and how many test cycles have been completed. If a 'Q' is pressed before the test is finished, the test is interrupted after the current cycle, and the user has the option to select the alternative “Continue the test” or stop the test by selecting the “0” alternative.
(102) BRU3 MANUAL [Main menu, Board Test, Look at test result] Test Status : SECOND Current test selection is MEDIUM 1. 2. 3. 4. 5. 6. Board FCB FRB FNB FMB FAB FPB 0. Board Test Menu SYS:yyyy-mm-dd hh:mm Comment Errors 0 NO_TEST 1 NO_TEST NO_TEST NO_TEST Choose Alternative: Figure 9 Test Status menu. BRU3 MANUAL, Doc.
FBTEST REFERENCE MANUAL 29 (102) The “Examine Board” Screen Select any menu alternative except “17” or “0” in the “Test Status” menu to get the “Examine Board” screen for the corresponding board. There is one “Examine Board” screen for each board which has been tested. This screen contains information about what kind of errors have been detected, and at which time. If there is a printer connected to the terminal, it is possible to get a hardcopy for each tested board.
(102) 6.2 BRU3 MANUAL Set Time [Main menu, Set Time] Set the System Clock Current test selection is MEDIUM 1. 2. 3. 4. 5. 0. Change Change Change Change Change SYS:yyyy-mm-dd hh:mm year (1901 - 2099). month (1 - 12). day (1 - 31). hour (0 - 23). minute (0 - 59). Main menu Choose alternative: Figure 11 Set System Clock menu. Alt. 1 modifies the year (entering 4-digit value) Alt. 2 modifies the month (entering value 1 - 12) Alt. 3 modifies the day (entering value 1 - 31) Alt.
FBTEST REFERENCE MANUAL 6.3 Radio Operations 6.3.1 Radio Control and Calibration Menu 31 (102) [Main menu, Radio Operations] Radio Control and Calibration Menu Current test selection is MEDIUM SYS:yyyy-mm-dd hh:mm 1 2 3 4 5 6 7 TRANSCEIVER SETUP MENU MEASUREMENT SETUP MENU TRANSCEIVER CONTROL AND PRESENTATION MENU CALIBRATION RADIO REGISTER EDITOR ADJUSTMENT SETUP 0. Main menu Choose alternative: Figure 12 Radio Control and Calibration Menu. Alt.
(102) BRU3 MANUAL Alt. 5 RADIO REGISTER EDITOR Displays the Radio Register Editor menu, Figure 37. Alt. 6 ADJUSTMENT Displays the Radio Adjustment menu, Figure 38. Alt. 7 SETUP Displays the Radio Setup menu, Figure 40. BRU3 MANUAL, Doc.
FBTEST REFERENCE MANUAL 6.3.2 33 (102) Transceiver Setup Menu [Main menu, Radio Operations, Transceiver Setup] Figure 13 Alt. 1 Transceiver Setup Menu (NUMBER MODE). SELECT NUMBER OR FREQUENCY MODE Displays the Transceiver Setup menu, (Number Mode in Figure 13 or Frequency Mode in Figure 14). This alternative is a toggle function between channel number mode and channel frequency mode. Conversion between these modes is done automatically.
(102) • BRU3 MANUAL DIVERSITY, radio build with diversity function, YES (= 1) or NO (= 0). NUMBER MODE Alt. 2 SET TX CHANNEL NUMBER Displays TX_CHANNEL NUMBER, TXCH = (3840) This alternative sets the transmitter channel number. A check is made to eliminate incorrect channel values. Alt. 3 SET TX POWER Displays SELECT TX_POWER = - 21.0 PRESS Y TO SELECT N TO NEXT [-21.0 (def), -18.0, -15.0, -12.0, -9.0, -6.0, -3.0, 0.0] The transmitter power is set in the following steps: 0.0, -3.0, -6.0, 9.
FBTEST REFERENCE MANUAL Alt. 5 35 (102) SET RX CHANNEL NUMBER Displays RX_CHANNEL NUMBER, RXCH = (3040) This alternative sets the receiver channel number. A check is made to eliminate incorrect channel values. Alt. 6 SET LOW OUTPUT POWER ALARM LIMIT Displays OUTPUT ALARM LIMIT = (10) This alternative sets the low output power limit. This value is transferred to the signal processor part, where it is checked against the calculated radio value.
(102) BRU3 MANUAL FREQUENCY MODE [Main menu, Radio Operations, Transceiver Setup] Figure 14 Alt. 2 Transceiver Setup Menu (FREQUENCY MODE). SET TX CHANNEL FREQUENCY Displays TX IN Hz, > = 890 000 000: TXFRQ = (939 000 000) This alternative sets the transmitter channel frequency. A check is made to eliminate incorrect channel values. Input frequency values are given in Hz as the channel separation is 12.5 kHz. Alt.3 SET TX POWER Please refer to NUMBER MODE BRU3 MANUAL, Doc.
FBTEST REFERENCE MANUAL Alt. 4 37 (102) SET TX MODULATION Please refer to NUMBER MODE Alt. 5 SET RX CHANNEL FREQUENCY Displays RX IN Hz, > = 890 000 000: RXFRQ =(900 000 000) This alternative sets receiver channel frequency. A check is made to eliminate incorrect channel values. Alt. 6 SET LOW OUTPUT POWER ALARM LIMIT Please refer to NUMBER MODE Alt. 7 SET VSWR ALARM LIMIT Please refer to NUMBER MODE BRU3 MANUAL, Doc.
(102) 6.
FBTEST REFERENCE MANUAL Alt. 10: 39 (102) SAVE TEST DATA AT STOP A toggle function between “+” (active) and “-” (inactive). This alternative, when active, stores test data when the test period is finished. This allows the operator to compare test data, while making test observations without saving, between the save instances. Alt. 11: SET TEST TIME Displays ENTER TEST_CYCLES (0) The number of test cycles is set, which is translated in to the time domain, if needed. BRU3 MANUAL, Doc.
(102) 6.4.1 BRU3 MANUAL Transceiver Control and Presentation Menu [Main menu, Radio Operations, Transceiver Control and Presentation] Transceiver Control and Presentation Menu Current test selection is MEDIUM TX: OFF TXCH: 1234 5 6 3840 PF: SYS:yyyy-mm-dd hh:mm 0 TXSEND:OFF SELECT TRANSMITTER ON/OFF SELECT MODULATION ON/OFF SAVE TEST DATA AT STOP SET TEST TIME:0 IS INDEFINITE START LOOK AT PREVIOUS TEST DATA RXCH: 3040 TEST CYCLES = 0 0.
FBTEST REFERENCE MANUAL Alt. 3 41 (102) SAVE TEST DATA AT STOP A toggle function between “ + “ (YES) and “ - “ (NO). Measurement data is saved when the test period is finished. Alt. 4 SET TEST TIME Displays ENTER TEST_CYCLES (10) The test period is set in cycles, which also correspond to time. A sampling rate of about 1 second is selected, but can be changed to a practical value if necessary. Alt. 5 START The start command starts the measurement. Alt.
(102) BRU3 MANUAL Operating conditions: TX: OFF TXCH: 3840 PF: 0 TXSEND: OFF RXCH: 3040 The status line, below the header, indicating the present operating conditions for the transceiver with the following meaning: • TX is the status of the transmitter, either OFF or ON. • TXCH or TXFRQ is the transmitter channel frequency or number. • PF is the transmitter power from 0 to -21 dB in 3 dB steps. • TXSEND is the transmitter modulation, shown as OFF, NONE, LOW, HIGH, AC, PRBS or PERIOD.
FBTEST REFERENCE MANUAL 6.4.2 43 (102) Radio Calibration Menu [Main menu, Radio Operations, Calibration] Figure 17 Alt. 1 Radio Calibration Menu. BANDGAP CALIBRATION Gives the Bandgap Calibration Menu, Figure 18. Alt. 2 TEMPERATURE SENSOR CALIBRATION Gives the Temperature Calibration Menu, Figure 19. Alt. 3 REFERENCE OCXO CALIBRATION Gives Reference Oscillator OCXO Calibration menu 1, Figure 21. Alt. 4 PF POWER CALIBRATION Gives PF Power Calibration menu 1, Figure 23. BRU3 MANUAL, Doc.
(102) Alt. 5 BRU3 MANUAL PR POWER CALIBRATION Gives PR Power Calibration menu 1, Figure 25. Alt. 6 VCO MODULATION CALIBRATION Gives VCO Calibration menu 1, Figure 27. Alt. 7 TCXO MODULATION CALIBRATION Gives TCXO Calibration menu 1, Figure 29. Alt. 8 RSSI CALIBRATION Gives RSSI Calibration menu 1, Figure 31. Alt. 9 EEPROM DISPLAY (EDITOR) This alternative selects a function that will display all calibration object values.
FBTEST REFERENCE MANUAL 6.4.3 45 (102) Bandgap Calibration [Main menu, Radio Operations, Calibration, Bandgap Calibration] Bandgap Calibration Current test selection is MEDIUM SYS:yyyy-mm-dd hh:mm CONNECT VOLTMETER TO BANDGAP VOLTAGE SIGNAL BANDGAP REFERENCE SET VALUE IS 128 NUM IS MEASURED VALUE EQUAL TO 2.5 V ? 1 2 3 4 0. INCREMENT DECREMENT SET VALUE MARK FOR STORAGE IN EEPROM Calibration Menu Choose alternative: Figure 18 Bandgap Calibration menu.
(102) BRU3 MANUAL Alt. 3 SET VALUE Displays VALUE (128) The value can be changed by increment, decrement or by set functions. Alt. 4 MARK FOR STORAGE IN EEPROM This alternative indicates that, this calibration object will be saved in EEPROM when the calibration procedure is finished. BRU3 MANUAL, Doc.
FBTEST REFERENCE MANUAL 6.4.4 47 (102) Temperature Sensor Calibration [Main menu, Radio Operations, Calibration, Temp. Sensor Calibration] Temperature Calibration SYS:yyyy-mm-dd hh:mm Current test selection is MEDIUM 1 2 SET OFFSET CALIBRATION MODE SET ABSOLUTE CALIBRATION MODE 0. Calibration Menu Choose alternative: _ Figure 19 Temperature Sensor Calibration menu. Alt. 1-2 Will display the Temperature Calibration menu, Figure 20. Alt. 1 Offset mode Alt. 2 Absolute mode BRU3 MANUAL, Doc.
(102) BRU3 MANUAL [Main menu, Radio Operations, Calibration, Temp. Sensor Calibration. 2] Temperature Calibration Current test selection is MEDIUM TX: OFF TXCH: 3840 TEMPERATURE A/D VALUE: 141 TEMPERATURE INDEX: 2 T1 T2 TDEG: -8.0 6.0 TNUM: 78 107 1 0 TXSEND:OFF T3 20.0 134 RXCH: T4 34.0 163 2 3 ENTER TEMPERATURE INDEX T1 - T5 FOR OFFSET/ABSOLUTE MODE ENTER CALIBRATION VALUE FOR OFFSET/ABSOLUTE MODE MARK FOR STORAGE IN EEPROM 0. Calibration Menu Figure 20 Alt 1.
FBTEST REFERENCE MANUAL 6.4.5 49 (102) Reference Oscillator OCXO Calibration [Main menu, Radio Operations, Calibration, Reference OCXO Calibration] Reference Oscillator OCXO Calibration SYS:yyyy-mm-dd hh:mm Current test selection is MEDIUM 1 SELECT OFFSET CALIBRATION MODE 2 SELECT ABSOLUTE CALIBRATION MODE 0. Calibration Menu Choose alternative: _ Figure 21 Reference Oscillator OCXO Calibration - 1 menu. Alt. 1-2 Will display the Reference Oscillator OCXO Calibration menus in Figure 22. Alt.
(102) BRU3 MANUAL [Main menu, Radio Operations, Calibration, Reference OCXO Calibration] Reference Oscillator OCXO Calibration Current test selection is MEDIUM TX: OFF TXCH: PF. INDEX: 2 T1 TDEG: -8.0 OCXO: 80 3840 T2 6.0 80 PF: 0 SYS:yyyy-mm-dd hh:mm TXSEND:OFF TEMP INDEX: 2 T3 20.0 81 RXCH: T4 34.0 81 3040 T5 48.0 81 IS OCXO FREQUENCY OK ON EXTERNAL INSTRUMENT ? 1 2 5 6 - 0.
FBTEST REFERENCE MANUAL 51 (102) Alt. 4 SET VALUE Sets VALUE (xx) The value can be changed by increment, decrement or by the set function. Alt. 5 MARK FOR STORAGE IN EEPROM After some changes of the old value, the new value can be marked for storage in EEPROM, when the calibration procedure is finished. Alt. 6 SELECT TRANSMITTER ON/OFF A toggle function between “ + “ (ON) and “ - “ (OFF). BRU3 MANUAL, Doc.
(102) 6.4.6 BRU3 MANUAL PF Output Power Calibration [Main menu, Radio Operations, Calibration, PF Power Calibration] PF Power Calibration Current test selection is MEDIUM SYS:yyyy-mm-dd hh:mm 1 2 SELECT OFFSET CALIBRATION MODE SELECT ABSOLUTE CALIBRATION MODE 0. Calibration Menu Choose alternative: Figure 23 PF Power Calibration menu. Alt. 1-2 Will display the PF Power Calibration menu in the next figure, Figure 24. Alt. 1 Offset mode Alt. 2 Absolute mode BRU3 MANUAL, Doc.
FBTEST REFERENCE MANUAL 53 (102) [Main menu, Radio Operations, Calibration, PF Power Calibration] PF Power Calibration Current test selection is MEDIUM TX: OFF TXCH: 3840 PF: PF. INDEX: 2 TDEG PFNUM: PFM: T1 -8.0 108 128 1 PFSET: -21.0 PFNUM: 101 PFM 1 2 3 7 118 0 SYS:yyyy-mm-dd hh:mm TXSEND:OFF RXCH: 3040 TEMP INDEX: 2 T2 6.0 107 126 T3 20.0 107 124 T4 34.0 107 121 T5 48.0 106 117 2 -18.0 107 3 -15.0 117 4 -12.0 128 5 -9.0 141 6 -6.0 157 7 -3.0 177 8 0.
(102) BRU3 MANUAL Alt. 2 ENTER TEMPERATURE INDEX FOR PF IN OFFSET/ ABSOLUTE MODE Displays TEMPERATURE INDEX (2) Alt. 3 INCREMENT Increases the value in steps. Alt. 4 DECREMENT Decreases the value in steps. Alt. 5 SET VALUE Displays VALUE (x) The alternatives, if the temperature check was OK, modify the output reference value. The measured output power on the external instrument is calibrated to the defined nominal value for the selected PF index.
FBTEST REFERENCE MANUAL 6.4.7 55 (102) PR Reflected Power Calibration [Main menu, Radio Operations, Calibration, PR Power Calibration] PR Power Calibration Current test selection is MEDIUM SYS:yyyy-mm-dd hh:mm 1 2 SELECT OFFSET CALIBRATION MODE SELECT ABSOLUTE CALIBRATION MODE 0. Calibration Menu Choose alternative: Figure 25 PR Power Calibration - 1 menu. Alt. 1-2 Will display PR Power Calibration menu 2, Figure 26. Alt. 1 Offset mode Alt. 2 Absolute mode BRU3 MANUAL, Doc.
(102) BRU3 MANUAL [Main menu, Radio Operations, Calibration, PR Power Calibration] Figure 26 Alt. 1 PR Power Calibration - 2 menu. SELECT TX POWER INDEX P1-P8 FOR OFFSET/ABSOLUTE MODE Displays SELECT TX_POWER = -21.0 PRESS Y TO SELECT N TO NEXT [-21.0 (def), -18.0, -15.0, -12.0, -9.0, -6.0, -3.0, 0.0] Alt.
FBTEST REFERENCE MANUAL Alt. 4 57 (102) MARK FOR STORAGE IN EEPROM This alternative indicates that this calibration object will be saved in EEPROM when the calibration procedure is finished. Alt. 5 SELECT TRANSMITTER ON/OFF A toggle function between “ + “ (ON) and “ - “ (OFF). Alt. 6 SLOT NUMBER [1-2] Displays the selected slot number. Enter the desired slot number Alt.
(102) 6.4.8 BRU3 MANUAL VCO Modulation Calibration [Main menu, Radio Operations, Calibration, VCO Calibration] VCO Calibration Current test selection is MEDIUM 1 2 0. SYS:yyyy-mm-dd hh:mm SELECT OFFSET CALIBRATION MODE SELECT ABSOLUTE CALIBRATION MODE Calibration Menu Choose alternative: _ Figure 27 VCO Calibration - 1 menu. Alt. 1-2 Will display the VCO Calibration menu 2, Figure 28. BRU3 MANUAL, Doc.
FBTEST REFERENCE MANUAL 59 (102) [Main menu, Radio Operations, Calibration, VCO Calibration] VCO Calibration Current test selection is MEDIUM TX: OFF TXCH: TEMP INDEX: 2 T1 TDEG: -8.0 VCO: 212 1 2 5 6 7 8 9 10 0. - 3840 PF: SLOT: T2 6.0 201 SYS:yyyy-mm-dd hh:mm 0 1 TXSEND:OFF CHANNEL: T3 20.0 189 RXCH: 3800 T4 34.0 182 3040 T5 48.
(102) Alt. 3 BRU3 MANUAL DECREMENT Decreases the value in steps. Alt. 4 SET VALUE Displays SET VCO (201) The value can be changed by increment, decrement or by set functions. Alt. 5 MARK FOR STORAGE IN EEPROM This alternative indicates that this calibration object will be saved in EEPROM when the calibration procedure is finished. Alt. 6 SELECT TRANSMITTER ON/OFF This alternative is a toggle function between “+” (ON) and “-” (OFF). Alt.
FBTEST REFERENCE MANUAL Alt. 9 61 (102) SELECT SLOT Displays SLOT NUMBER [1-3] (1) 34xx: For each slot the calibration has to be done at three different frequencies. The frequency band, selected in the “Radio Operation Parameters in menu” in Figure 17, shall be divided into the current number of slots. The number of slots is determined by the total frequency band covered by the BRU3 variant. 38xx and 39xx: The calibration is done at one frequency. Enter SLOT NUMBER = 1. Alt.
(102) 6.4.9 BRU3 MANUAL TCXO Modulation Calibration [Main menu, Radio Operations, Calibration, TCXO Calibration] TCXO Calibration Current test selection is MEDIUM SYS:yyyy-mm-dd hh:mm 1 2 SELECT OFFSET CALIBRATION MODE SELECT ABSOLUTE CALIBRATION MODE 0. Calibration Menu Choose alternative: Figure 29 TCXO Calibration - 1 menu. Alt. 1-2 Displays TCXO Calibration menu 2, Figure 30. BRU3 MANUAL, Doc.
FBTEST REFERENCE MANUAL 63 (102) [Main menu, Radio Operations, Calibrations, TCXO Calibration] TCXO Calibration Current test selection is MEDIUM TX: OFF TXCH: 3840 PF: SYS:yyyy-mm-dd hh:mm 0 TXSEND:OFF RXCH: 3040 TEMP INDEX: 2 TDEG: TCXO: 1 T1 -8.0 234 T2 6.0 234 T3 20.0 234 T4 34.0 234 T5 48.
(102) Alt. 1 BRU3 MANUAL ENTER TEMPERATURE INDEX T1-T5 FOR OFFSET/ ABSOLUTE MODE Displays TEMPERATURE INDEX (2) The temperature index is selected and the temperature check, as described for temperature calibration, is initiated. Alt. 2 INCREMENT Increases the value in steps. Alt. 3 DECREMENT Decreases the value in steps. Alt. 4 SET VALUE Display SET TCXO (215) If the temperature check was OK these alternatives modify the output gain value.
FBTEST REFERENCE MANUAL Alt. 7 65 (102) SELECT MODULATION Selects the modulation Displays SELECT MODULATION = NONE SELECT NO FOR NEXT PRESS Y TO [NONE (default), AC, LOW, HIGH, PRBS, PERIOD, SINE] Alt. 8 SELECT MODULATION ON/OFF This function is a toggle function between “+” (ON) and “-” (OFF). Alt. 9 VCO MODULATION ON/OFF This function is a toggle function between “+” (ON) and “-” (OFF). BRU3 MANUAL, Doc.
(102) 6.4.10 BRU3 MANUAL RSSI Calibration [Main menu, Radio Operations, Calibration, RSSI Calibration] RSSI Calibration Current test selection is MEDIUM TX: OFF TXCH: RSSI INDEX: 2 T1 T2 TDEG: -7.0 3.0 RSSI: 85 108 3840 T3 13.0 126 T4 23.0 143 PF: T5 33.0 164 SYS:yyyy-mm-dd hh:mm 0 TXSEND:OFF T6 43.0 169 T7 53.0 169 T8 63.0 167 RXCH: 3040 T9 T10 73.0 83.
FBTEST REFERENCE MANUAL 67 (102) Alt. 1 SELECT RSSI INDEX S1-S10 FOR OFFSET/ABSOLUTE MODE Displays RSSI SIGNAL INDEX (2) The RSSI index is selected. The measured RSSI value is entered at reference index point, when the signal strength is set to the defined value at the external instrument. Alt. 2 READ AND ENTER CALIBRATION VALUE Alt 3 MARK FOR STORAGE IN EEPROM This alternative indicates that this calibration object will be saved in EEPROM when the calibration procedure is finished. BRU3 MANUAL, Doc.
(102) 6.4.11 BRU3 MANUAL EEPROM Display Editor Menu [Main menu, Radio Operations, Calibration, EEPROM Display Editor-1] Figure 32 Alt.1 EEPROM Display menu - screen 1. SELECT SCREEN 1 This menu BRU3 MANUAL, Doc.
FBTEST REFERENCE MANUAL 69 (102) Alt. 2 SELECT SCREEN 2 [Main menu, Radio Operations, Calibration, EEPROM Display Editor-2] Figure 33 EEPROM Display menu - screen 2. BRU3 MANUAL, Doc.
(102) Alt. 3 BRU3 MANUAL SELECT SCREEN 3 [Main menu, Radio Operations, Calibration, EEPROM Display Editor-3] Figure 34 EEPROM Display menu - screen 3. BRU3 MANUAL, Doc.
FBTEST REFERENCE MANUAL 71 (102) Alt. 4 SELECT SCREEN 4 [Main menu, Radio Operations, Calibration, EEPROM Display Editor-4] Figure 35 EEPROM Display menu - screen 4. BRU3 MANUAL, Doc.
(102) 6.4.12 BRU3 MANUAL PA Bias and FDAC Calibration Menu [Main menu, Radio Operations, Calibration, PA Bias and FDAC Calibration] Figure 36 Alt. 1 PA Bias and FDAC Calibration Menu. SET PA BIAS DRIVER Shows the current setting of the driver bias (a). Alt. 2 SET PA BIAS FINAL Shows the current setting of the final bias (a). Alt. 3 SET FDAC RX Shows the current setting of the Rx syntheziser (a). Alt. 4 SET FDAC TX Shows the current setting of the Tx syntheziser (a). BRU3 MANUAL, Doc.
FBTEST REFERENCE MANUAL Alt. 5 73 (102) SETUP RADIO OPERATION PARAMETERS Shows the current setting of the radio operation parameters (a). Alt. 6 SELECT TRANSMITTER ON/OFF Shows the current setting of the transmitter (a). (a) When a new value is entered it takes effect on the radio board immediately. The new value will be stored in the EEPROM after confirmation. The setting can be changed by entering a new value. BRU3 MANUAL, Doc.
(102) 6.4.13 BRU3 MANUAL Radio Register Editor Menu [Main menu, Radio Operations, Radio Register Editor] Radio Register Editor Menu Current test selection is MEDIUM 1 2 READ RADIO REGISTER WRITE RADIO REGISTER 0. Previous Menu SYS:yyyy-mm-dd hh:mm Choose alternative: _ Figure 37 Alt. 1 Radio Register Editor Menu. READ RADIO REGISTER Displays “ADDRESS = (1)”. enabling reading of the address number. Alt. 2 WRITE RADIO REGISTER Displays “ADDRESS = (1)”.
FBTEST REFERENCE MANUAL 6.4.14 75 (102) Adjustment [Main menu, Radio Operations, Adjustment] Radio Adjustment Menu Current test selection is MEDIUM SYS:yyyy-mm-dd hh:mm 1 2 OCXO AGE ADJUSTMENT SAVE ADJUSTMENT IN EEPROM 0. Radio Control and Calibration Menu Choose alternative: _ Figure 38 Alt. 1 Radio Adjustment Menu. OCXO AGE ADJUSTMENT Displays the menu in Figure 39. Alt. 2 SAVE ADJUSTMENT IN EEPROM Saves the adjustment in EEPROM. BRU3 MANUAL, Doc.
(102) BRU3 MANUAL [Main menu, Radio Operations, Adjustment, OCXO Age Adjustment] OCXO Age Adjustment Menu Current test selection is MEDIUM SYS:yyyy-mm-dd hh:mm CURRENT ADJUSTMENT VALUE IS 0 1 2 3 4 INCREMENT DECREMENT SET VALUE MARK FOR STORAGE IN EEPROM 0. Adjustment menu Choose alternative: _ Figure 39 Alt. 1 OCXO Age Adjustment Menu. INCREMENT Increases the CURRENT ADJUSTMENT VALUE in steps. Alt. 2 DECREMENT Decreases the CURRENT ADJUSTMENT VALUE in steps. Alt.
FBTEST REFERENCE MANUAL Alt. 4 77 (102) MARK FOR STORAGE IN EEPROM This alternative indicates that this calibration object will be saved in EEPROM when the calibration procedure is finished. BRU3 MANUAL, Doc.
(102) 6.4.15 BRU3 MANUAL Setup [Main menu, Radio Operations, Setup] Figure 40 Alt. 1 Radio Setup Menu. FREQUENCY BAND A toggle function between 400-1, 400-2, 800, 819 and 900 MHz. This alternative is used to choose between the 400-1 and 400-2 MHz, 800 and 819 MHz and 900 MHz bands. 400-2 equals the UK National frequency band. 400-1 equals all other 400 MHz frequency bands including the UK City frequency band.
FBTEST REFERENCE MANUAL Alt. 3 79 (102) RADIO BOARD ROA Toggles radio board between: Alt. 4 • Unknown (old) • ROA 1179842/1 (900 MHz) • ROA 1179842/3 (800 MHz) • ROA 117 8897 (400 MHz) RADIO BOARD ROA REVISION Sets radio board revision number Alt. 5 DEFAULT TX CHANNEL NUMBER Displays DISPL. TX CHAN. (3840) Sets the transmitter channel number. Alt. 6 DEFAULT RX CHANNEL NUMBER Displays DISPL. RX CHAN. (3040) Sets the receiver channel number. Alt.
(102) BRU3 MANUAL 6.5 Modem Operation Menu [Main menu, Modem Operations] Modem Operation SYS:yyyy-mm-dd hh:mm Current test selection is MEDIUM 1. 2. 3. 4. Line Speed on Modem port DTR status RTS status Transparent Mode access 0. Main menu 9600 OFF OFF Choose alternative: Figure 41 Alt. 1 Modem Operation menu.
FBTEST REFERENCE MANUAL 6.6 81 (102) Status Overview Menu [Main menu, Status Overview] Figure 42 Status Overview menu. Figure 42 “Status Overview menu.” shows an example of the Status Overview menu. Status Line “DAA Status” will display the current country code. BRU3 MANUAL, Doc.
(102) 6.7 BRU3 MANUAL Edit Loader Parameters Menu [Main menu, Edit Loader Parameters] Edit Loader Parameters Current test selection is MEDIUM 1. 2. 3. 4. 5. 6. Node 0 Ports Channels Connections Read parameters from Flash Store parameters to Flash 0. Main menu SYS:yyyy-mm-dd hh:mm Choose alternative: Figure 43 Note! Alt. 1 Edit Loader Parameters menu. Normally, an edit session starts with the selection of alt 5., to read in the present values from Flash.
FBTEST REFERENCE MANUAL Alt. 2 PORTS Displays the “Define Ports menu” in Figure 44. Alt. 3 CHANNELS Displays the “Define Channels menu” in Figure 50. Alt. 4 CONNECTIONS Displays the “Define Connections menu” in Figure 53. Alt. 5 READ PARAMETERS FROM FLASH Reads the parameters stored in flash. Alt. 6 STORE PARAMETERS TO FLASH Saves the parameters in FLASH. BRU3 MANUAL, Doc.
(102) 6.7.1 BRU3 MANUAL Ports [Main menu, Edit Loader Parameters, Ports] Define ports Current test selection is MEDIUM 1. 2. Port Not in use : 0. Previous menu SYS:yyyy-mm-dd hh:mm 1 Choose alternative: Figure 44 Alt. 1 Define Ports - “Not in use” menu. PORT Displays Port number [1-1]:(1) The desired physical port can only be set to “1” as only one port is available on the BRU3. Alt. 2 NOT IN USE Selects between “Not in use” or “In use” by toggling.
FBTEST REFERENCE MANUAL 85 (102) [Main menu, Edit Loader Parameters, Ports] Define ports SYS:yyyy-mm-dd hh:mm Current test selection is MEDIUM 1 2 3 4 5 6 Port In use Unit number Local port number Modem parameters X25 parameters 0. Previous menu : 1 : 0 : 1 Choose alternative: _ Figure 45 Alt. 1 Define Ports - “In use” menu. PORT Choose alternative: Port number [1 - 1]: (1) Alt. 2 IN USE Selects between “Not in use” or “In use” by toggling. The select “In use” displays the menu in Figure 44.
(102) Alt. 4 BRU3 MANUAL LOCAL PORT NUMBER Choose alternative: Local port number [1 - 1] (1) As only one local port is available on the BRU3, the set value should be “1”. Alt. 5 MODEM PARAMETERS Displays the Port - Modem Parameter menu in Figure 46. Alt. 6 X.25 PARAMETERS Displays the Port - X.25 Parameter menu in Figure 49. BRU3 MANUAL, Doc.
FBTEST REFERENCE MANUAL 87 (102) [Main menu, Edit Loader Parameters, Ports, Modem Parameters] Define modem parameters Current test selection is MEDIUM 1 2 3 4 5 6 7 8 Modem in use Control type Prompt Bitrate Dial timeout Answer timeout Init commands Dial commands 0. Previous menu : : : : : : SYS:yyyy-mm-dd hh:mm YES ATHAYES OK 9600 60 60 Choose alternative: Figure 46 Alt. 1 Edit Modem Parameters menu. MODEM IN USE A toggle function between YES or NO. Alt.
(102) Alt. 4 BRU3 MANUAL BIT RATE A toggle function between bit rates 1200, 2400, 4800, 9600 and 14400, where the bit rate normally should be set to 9600, but it is possible to select other rates by toggling. Note! This bit rate setting is related to asynchronous communication (sending initiation commands to the modem). Alt. 5 DIAL TIMEOUT The Dial Timeout in seconds should be entered. Dial timeout [sec][0 - 500]: (0) The value should normally be 60 sec. Alt.
FBTEST REFERENCE MANUAL Alt. 8 89 (102) DIAL COMMANDS Displays the 10 Dial Command sequences, please refer to the menu in Figure 48. [Main menu, Edit Loader Parameters, Ports, Modem Parameters, Init Commands] Modem Initial Command for Port 1 Current test selection is MEDIUM 1 2 3 4 5 Command Command Command Command Command 1 2 3 4 5 : : : : : 0. Previous menu SYS:yyyy-mm-dd hh:mm ATE0 AT&D2 AT&M1 Choose alternative: _ Figure 47 Note! Edit Modem Parameters menu, Init Commands.
(102) BRU3 MANUAL [Main menu, Edit Loader Parameters, Ports, Modem Parameters, Dial Commands] Modem Dial Command for Port 1 Current test selection is MEDIUM 1 2 3 4 5 6 7 8 9 10 SYS:yyyy-mm-dd hh:mm : ATD543301 : ATD543302 : : : : : : : : 1 2 3 4 5 6 7 8 9 10 Command Command Command Command Command Command Command Command Command Command 0. Previous menu Choose alternative: _ Figure 48 Edit Modem Parameters menu, Dial Commands. BRU3 MANUAL, Doc.
FBTEST REFERENCE MANUAL 91 (102) [Main menu, Edit Loader Parameters, Ports, X.25 Parameters] X25 parameters for port 1 Current test selection is MEDIUM 1 2 3 4 5 6 7 8 Local address Packet size Window size Bitrate Ltc channel Htc channel Network Network ID 0. Previous menu : : : : : : : : SYS:yyyy-mm-dd hh:mm 1 512 2 9600 bps 1 8 X25 Network 255 Choose alternative: Figure 49 Alt 1. Edit X.25 Parameters menu. Enter the LOCAL ADDRESS: Enter your own X.25 address. Alt 2.
(102) 6.7.2 BRU3 MANUAL Channels Alt. 3 “Channels” in the Edit Loader Parameters Menu displays the following menu: [Main menu, Edit Loader Parameters, Channels] Define channels SYS:yyyy-mm-dd hh:mm Current test selection is MEDIUM 1. 2. Channel Not in use : 1 0. Previous menu Choose alternative: _ Figure 50 Define Channels menu. If alternative 1 is selected, the “Choose alternative” will change to: Channel number [1 - 5]: (1). BRU3 MANUAL, Doc.
FBTEST REFERENCE MANUAL 93 (102) [Main menu, Edit Loader Parameters, Channels] Define channels SYS:yyyy-mm-dd hh:mm Current test selection is MEDIUM 1. 2. 3. 4. 5. Channel In use Port Local channel number X.25 Parameters 0. Previous menu : 1 : : 1 1 Choose alternative: _ Figure 51 Define Channels menu. Alt 1. Enter the Channel number [1 - 5]:(1), select the channel number to be edited. Alt 3. Enter the Port number [1 - 1]:(1) Alt 4. Enter the Local channel number [0 - 255]:(1) Alt 5.
(102) BRU3 MANUAL [Main menu, Edit Loader Parameters, Channels, X.25 Parameters] X.25 parameters for channel 1 Current test selection is MEDIUM 1. 2. 3. 4. 5. 6. 7. 8. Remote address Packet size Window size Connection type Logical channel Request rev chg Accept rev chg Accept empty addr 0. Previous menu : : : : : : : : SYS:yyyy-mm-dd hh:mm 00000 128 2 VC -1 No Yes No Choose alternative: _ Figure 52 25 Parameters for Channel 1 menu. Alt 1. Enter the Remote address: The Address for the MOX.
FBTEST REFERENCE MANUAL 6.7.3 95 (102) Connections Alt. 4 “Connections” in the Edit Loader Parameters Menu displays the following menu: [Main menu, Edit Loader Parameters, Connections] Define connections Current test selection is MEDIUM 1. 2. Connection Not in use : 0. Previous menu SYS:yyyy-mm-dd hh:mm 1 Choose alternative: Figure 53 Define Connection menu. Alt 1. Enter the Connection number [1 - 5]:(1) Alt 2. A choice between NOT IN USE and IN USE.
(102) BRU3 MANUAL [Main menu, Edit Loader Parameters, Connections] Define connections Current test selection is MEDIUM 1. 2. 3. 4. 5. Connection In use Remote node Priority Channel 0. Previous menu : 1 : : : 0 0 1 Choose alternative: Figure 54 SYS:yyyy-mm-dd hh:mm _ Edit Loader Parameters menu - selection of connection. Alt 1. Enter the Connection number [1 - 5]:(0) Alt 2. Enter the Remote node number [0 - 99999]:(0) Alt 3. Enter the Priority [0 - 255]:(0) Alt 4.
FBTEST REFERENCE MANUAL 6.7.4 97 (102) Read Parameters from FLASH [Main menu, Edit Loader Parameters, Read Parameters from FLASH] Edit loader parameters Current test selection is MEDIUM 1 2 3 4 5 6 Node XXXXX Ports Channels Connections Read parameters from Flash Store parameters to Flash 0. Main menu SYS:yyyy-mm-dd hh:mm Choose alternative: Figure 55 Edit Loader Parameters menu - selection of parameters. Alt 1. Enter your own node number [0 - 9999]: (xxxxx) Alt 2.
(102) 6.7.5 BRU3 MANUAL Store Parameters in FLASH The messages “Storing data in Flash”, followed by “Data stored successfully in Flash” will be briefly displayed. The menu will then return to normal display: [Main menu, Edit Loader Parameters, Store Parameters in FLASH] Edit loader parameters Current test selection is MEDIUM 1 2 3 4 5 6 Node XXXXX Ports Channels Connections Read parameters from Flash Store parameters to Flash 0.
FBTEST REFERENCE MANUAL 7 99 (102) Index Adjustment Alarm Limit Answer Timeout Bandgap Bit rate Board Test Cable loss Calibration Calibration Value Channels Connections Control Type Dial Commands Dial Timeout DTR Status EEPROM Extended Test Frequency Frequency Mode Init Commands Line Speed Loader Parameters Low Output Power Main Menu Measurement Setup Medium Test Modem Operation Modem Parameters Modulation Modulation ON/OFF Node 0 Number Mode OCXO Age Adjustment Parameters PF Output Power Port Number Po
(102) BRU3 MANUAL Prompt Radio Radio Control Radio Operation Radio Register Radio Setup Reference Oscillator OCXO RSSI RSSI Index S1-S10 RTS Status RX Channel Frequency RX Channel Number Set Time Setup Slot Channel Slot Selection Status Overview Store Parameters in FLASH TCXO Modulation Temperature Index Temperature Index for OCXO Temperature Index T1 - T5 Temperature Sensor Test Cycles Test Parameters, FCB - FE Computer Board Test Parameters, FMB - FE Modem Board Test Parameters, FNB - FE Connection
FBTEST REFERENCE MANUAL 7.
(102) BRU3 MANUAL BRU3 MANUAL, Doc.