FBTEST Reference Manual Contents 1 Introduction ................................................................................................. 3 1.1 Field of Application ......................................................................... 3 1.2 Date and Time Window ................................................................... 4 1.3 FBTEST Menu Overview ................................................................ 5 2 Installation Procedures ..................................................
BRU1/BRU3 MANUAL 6.2 6.3 6.4 6.5 6.6 6.7 6.8 6.9 6.1.12 Alt. 10 (BRU1): Set Parameters for FIB - FE Interface Board ...................................................................................31 6.1.13 Alt. 11: Set Params for FPB – FE Power Supply Board (BRU3 only) ........................................................................32 6.1.14 Alt.12: Look at Test Results ................................................33 Set Time ...............................................................
FBTEST REFERENCE MANUAL 1 3 (110) Introduction FBTEST is a test program for the Base Radio Unit 1 (BRU1) and Base Radio Unit 3 (BRU3). Two types of user interfaces are available through a serial communication port. One by a menu-oriented structure where test alternatives and parameters are selected by stepping through the menus. The other interface is by command frame input, suitable for automatic testing with computer supervision over a communication line.
(110) BRU1/BRU3 MANUAL The information applicable when commissioning shall take place is described in the following sections: • Set System Clock Menu • Radio Control and Calibration Menu, alternatives 1-3 • Status Overview Menu • Modem Operation Menu • Edit Loader Parameters Menu 1.2 Date and Time Window The date and time window in the upper right-hand corner shows the system clock, marked with SYS:. BRU1/BRU3 MANUAL, Doc.
FBTEST REFERENCE MANUAL 1.
(110) BRU1/BRU3 MANUAL --------Measurement Setup Menu -------------Select Transmitter ON/OFF -------------Save Test Data at Stop -------------Set Test Time --------Transceiver Control and Presentation Menu -------------Select Transmitter ON/OFF -------------Select Modulation ON/OFF -------------Save Test Data at Stop -------------Set Test Time -------------Start -------------Look at previous data --------Radio Calibration Menu -------------Bandgap Calibration Menu ------------------Increment -----------
FBTEST REFERENCE MANUAL -------------PR Reflected Power Calibration Menu ------------------Select TX Power Ind. P1-P8 for Offs./Abs.Mode ------------------Enter Temp. Index T1-T5 for Offset/Abs. Mode ------------------Read and enter Calibr. Value for Offset Mode ------------------Mark for Storage in EEPROM ------------------Select Transmitter ON/OFF ------------------Slot Number ------------------Attenuation -------------VCO Modulation Calibration Menu ------------------Enter Temp.
(110) BRU1/BRU3 MANUAL -------------Save Calibration in EEPROM -------------Setup Radio Operation Parameters -------------PA Bias and FDAC Calibration Menu ------------------PA Bias Driver ------------------PA Bias Final ------------------FDAC Rx ------------------FDAC Tx ------------------Setup Radio Operation Parameters ------------------Set Transmitter On/Off --------Radio Register Editor Menu -------------Read Radio Register -------------Write Radio Register --------Adjustment Menu -------------OCXO
FBTEST REFERENCE MANUAL 9 (110) -------------Unit Number -------------Local Port Number 95 96 -------------Modem Parameter Menu ------------------Modem in use ------------------Control Type ------------------Prompt ------------------Bit rate ------------------Dial Timeout ------------------Answer Timeout ------------------Init Commands Menu ----------------- Dial Commands Menu -------------X.25 Parameters Menu --------Channels Menu -------------X.
(110) 2 BRU1/BRU3 MANUAL Installation Procedures Load FBTEST by using ZMODEM during the procedure of installing the node software. For details, see NTE Client Library/Node Software/Software Commissioning Procedure. BRU1/BRU3 MANUAL, Doc.
FBTEST REFERENCE MANUAL 3 11 (110) Hardware, Equipment and Preparation The preparation work necessary for testing a node is kept at a minimum. A console terminal has to be attached to the Console Connector on the node, and if a test that requires external hardware is to be executed, special test cables are to be connected. 3.1 Configuration All terminal inputs and outputs are directed to the console. The console should be a VT100 terminal or the equivalent.
(110) 3.2 BRU1/BRU3 MANUAL External Tests requiring External Hardware Some of the external tests require external hardware. The external tests in question are: • Loopback Test of FNB Board • Loopback Test of Ethernet in FIB Board (BRU1 only) • RFTL Test of FRB Board • Modem Tests (BRU3 only) A Loopback test is carried out of the FNB Board by using a 25 pin D-Sub plug. One of the physical ports is selected according to strapping alternative RS232 or RS422.
FBTEST REFERENCE MANUAL 13 (110) Node Hardware Library/BRU1. When the OEM-Strap is set to Open, BOOT will automatically start FBTEST, and FBTEST will automatically start its command frame mode. This procedure is not described in this document. BRU1/BRU3 MANUAL, Doc.
(110) 4 BRU1/BRU3 MANUAL FBTEST User Modes FBTEST can be executed in two different user modes. One mode is implemented with menus while the other mode involves the use of a command frame protocol. The menu mode is interactive and the selected test is executed after set up of its parameters. The command frame mode is designed to allow control of execution from an external computer. BRU1/BRU3 MANUAL, Doc.
FBTEST REFERENCE MANUAL 5 15 (110) User Interface Description This section describes all the menus that are used in the FBTEST. When the FBTEST program is loaded and started, the Main Menu is displayed on the console terminal. The program is then ready to accept commands. 5.1 Working with Menus The user interface is quite straight-forward but the following must be noted: • To choose a menu alternative: Write the corresponding number and press .
(110) 5.1.2 BRU1/BRU3 MANUAL Menu Displays For the various menu examples shown in this document the respective “paths”, i.e., the hierarchic structure is indicated, to facilitate the selection of the desired menus. See the example below: [Main menu, Radio Operations, Calibration] BRU1/BRU3 MANUAL, Doc.
FBTEST REFERENCE MANUAL 6 17 (110) Main Menu When the FBTEST program is started, the Main Menu is displayed on the screen, see Figure 1 “Main menu (BRU3).” and Figure 2 “Main menu (BRU1).”. Depending on selected alternative, different submenus will be displayed, as described below the figure. [Main menu] Figure 1 Main menu (BRU3). BRU1/BRU3 MANUAL, Doc.
(110) Figure 2 BRU1/BRU3 MANUAL Main menu (BRU1). BRU1/BRU3 MANUAL, Doc.
FBTEST REFERENCE MANUAL 19 (110) The selected alternative will display other menus as follows: Alt. 1 BOARD TEST Displays the Board Test menu, Figure 3 for BRU3 and Figure 4 for BRU1. Alt. 2 SET TIME Displays the Set System Clock menu, Figure 17. Alt. 3 RADIO OPERATIONS Displays the Radio Control and Calibration menu, Figure 18. MODEM OPERATIONS Alt. 4 (BRU3) Displays the Modem Operation menu, Figure 47. Alt. 4 INTERFACE BOARD (BRU1) Displays the Interface Board (for BRU1 only), Figure 48. Alt.
(110) 6.1 BRU1/BRU3 MANUAL Board Test Menu This menu is shown if alternative 1, “Board Test”, is selected in the Main Menu. From this menu, all tests can be configured and executed. The batch test sequence for each board type is chosen from the different board type menus, and so are all the interactive tests. Figure 3 “Board Test menu (BRU3).” and Figure 4 “Board Test menu (BRU1).” shows the Board Test Menu.
FBTEST REFERENCE MANUAL 21 (110) Board Test menu SYS:2004-01-13 0:27 Current test selection is MEDIUM 1 2 3 4 5 6 7 8 1 Do the test Number of test cycles (0=Forever) Select/unselect boards Select extended test (External HW needed) Select medium test Unselect all tests Set test parameters for FCB Set test parameters for FRB 10 Set test parameters for FIB 12 Look at test results 0 Main menu Choose alternative: Figure 4 Board Test menu (BRU1). BRU1/BRU3 MANUAL, Doc.
(110) 6.1.1 BRU1/BRU3 MANUAL Alt. 1: Do the Test This alternative starts the batch test which will execute all selected tests on all selected boards. The tests is defined by: • number of cycles • type of board test mode (extended, medium userdefined) • selected boards • selected tests for each board 6.1.2 Alt. 2: Number of Test Cycles This alternative will display the question “Number of cycles”: (1). Accordingly, the default value is 1.
FBTEST REFERENCE MANUAL 6.1.3 23 (110) Alt. 3: Select/Unselect Boards Displays a submenu, where all boards can be selected or unselected, and included in or excluded from the test by using the toggle function. Figure 5 “Example of select/unselect menu (BRU3).” and Figure 6 “Example of select/unselect menu (BRU1).” gives an example of this menu.
(110) BRU1/BRU3 MANUAL Select/unselect boards SYS:2004-01-13 0:28 Current test selection is MEDIUM 1 2 3 + + + Board type FCB FRB FIB Comment 0. Board Test menu Choose alternative: Figure 6 Example of select/unselect menu (BRU1). Note: “ + ” = select “ - “ = unselect BRU1/BRU3 MANUAL, Doc.
FBTEST REFERENCE MANUAL 6.1.4 25 (110) Alt. 4: Select Extended Test The extended test is a quick-choice alternative to turn on all possible, not interactive tests, for those boards that are selected. External hardware is needed for certain tests. 6.1.5 Alt. 5: Select Medium Test The medium test is a quick-choice alternative to activate tests for selected boards, which do not require interactive operator involvement or external hardware. 6.1.6 Alt.
(110) BRU1/BRU3 MANUAL 6.1.8 Alt.7: Set Parameters for FCB – FE Computer Board [Main menu, Board Test, Set test parameters for FCB] Test for FCB Current test selection is MEDIUM 1 2 3 4 5 6 7 8 9 + + + + - 0. SYS:yyyy-mm-dd hh:mm DRAM test Exhaustive DRAM test DPRAM test Signal Processor test Communication IC Internal test FLASH Boot Memory test FLASH System Memory test Alarm test Ethernet Module test Test menu Choose alternative: Figure 7 Test for FCB – FE Computer Board (BRU3). Alt.
FBTEST REFERENCE MANUAL Test for FCB Current test selection is MEDIUM 1 2 3 4 5 6 7 + + + + - 0. 27 (110) SYS:2004-01-13 0:29 DRAM test Exhaustive DRAM test DPRAM test Signal Processor test Communication IC Internal test FLASH Boot Memory test FLASH System Memory test Test menu Choose alternative: Figure 8 Test for FCB – FE Computer Board (BRU1). Alt. 1 - 8 A toggle function between “+” (select) and ”-” (unselect), is used to include or exclude boards from the test.
(110) BRU1/BRU3 MANUAL 6.1.9 Alt. 8: Set Parameters for FRB – FE Radio Board [Main menu, Board Test, Set test parameters for FRB] Test for FRB SYS:yyyy-mm-dd hh:mm Current test selection is MEDIUM 1 2 3 0. + + - Alarm test EEprom test Radio Loopback test Test menu Choose alternative: Figure 9 Test for FRB – FE Radio Board. Alt. 1 - 3 A toggle function between “+” (select) and ”-” (unselect), is used to select the type of tests that should be performed.
FBTEST REFERENCE MANUAL 6.1.10 29 (110) Alt. 9: Set Parameters for FNB – FE Connection Board (BRU3 only) [Main menu, Board Test, Set test parameters for FNB] Test for FNB SYS:yyyy-mm-dd hh:mm Current test selection is MEDIUM 1 2 0. - Serial Loopback - RS232 or RS422 Alarm Interface test Test menu Choose alternative: Figure 10 Test for FNB – FE Connection Board. Alt. 1 - 2 A toggle function between “+” (select) and ”-” (unselect), used to include or exclude boards from the test.
(110) BRU1/BRU3 MANUAL 6.1.11 Alt. 10 (BRU3): Set Parameters for FMB – FE Modem Board [Main menu, Board Test, Set test parameters for FMB] Test for FMB SYS:yyyy-mm-dd hh:mm Current test selection is MEDIUM 1 2 3 0. - Internal Modem test Local Loopback test Remote Loopback test Test menu Choose alternative: Figure 11 Test for FMBF – FE Modem Board. Alt. 1 - 3 A toggle function between “+” (select) and ”-” (unselect), is used to include or exclude boards from the test.
FBTEST REFERENCE MANUAL 6.1.12 31 (110) Alt. 10 (BRU1): Set Parameters for FIB - FE Interface Board [Main menu, Board Test, Set test parameters for FIB] Tests for FIB SYS:2004-01-13 0:29 Current test selection is USER_DEFINED 1 2 3 4 5 0. + + + - Ethernet Loopback test Alarm test Power Alarm test Temperature Alarm test Serial Loopback - RS232 or RS422 Test menu Choose alternative: Figure 12 Test for FIB (BRU1). Alt.
(110) BRU1/BRU3 MANUAL 6.1.13 Alt. 11: Set Params for FPB – FE Power Supply Board (BRU3 only) [Main menu, Board Test, Set test parameters for FPB] Test for FPB SYS:yyyy-mm-dd hh:mm Current test selection is MEDIUM 1 0. - Alarm test Test menu Choose alternative: Figure 13 Alt. 1 Test for FPB – FE Power Supply Board. A toggle function between “+” (select) and ”-”(unselect). Note: “ + ” = select “ - “ = unselect BRU1/BRU3 MANUAL, Doc.
FBTEST REFERENCE MANUAL 6.1.14 33 (110) Alt.12: Look at Test Results When the batch tests are started, the Test Status is shown. It tells you how many faults have been detected for each board, and how many test cycles have been completed. If a 'Q' is pressed before the test is finished, the test is interrupted after the current cycle, and the user has the option to select the alternative “Continue the test” or stop the test by selecting the “0” alternative.
(110) BRU1/BRU3 MANUAL [Main menu, Board Test, Look at test result] Test Status : SECOND Current test selection is MEDIUM SYS:yyyy-mm-dd hh:mm Comment 1. 2. 3. 4. 5. Board FCB FRB FNB FMB FPB 0. Board Test Menu Errors 0 NO_TEST 1 NO_TEST NO_TEST Choose Alternative: Figure 14 Test Status menu (BRU3). BRU1/BRU3 MANUAL, Doc.
FBTEST REFERENCE MANUAL Figure 15 Test Status menu (BRU1). BRU1/BRU3 MANUAL, Doc.
(110) BRU1/BRU3 MANUAL The “Examine Board” Screen Select any menu alternative except “17” or “0” in the “Test Status” menu to get the “Examine Board” screen for the corresponding board. There is one “Examine Board” screen for each board which has been tested. This screen contains information about what kind of errors have been detected, and at which time. If there is a printer connected to the terminal, it is possible to get a hardcopy for each tested board.
FBTEST REFERENCE MANUAL 6.2 37 (110) Set Time [Main menu, Set Time] Set the System Clock Current test selection is MEDIUM 1. 2. 3. 4. 5. 0. Change Change Change Change Change SYS:yyyy-mm-dd hh:mm year (1901 - 2099). month (1 - 12). day (1 - 31). hour (0 - 23). minute (0 - 59). Main menu Choose alternative: Figure 17 Set System Clock menu. Alt. 1 modifies the year (entering 4-digit value) Alt. 2 modifies the month (entering value 1 - 12) Alt. 3 modifies the day (entering value 1 - 31) Alt.
(110) BRU1/BRU3 MANUAL 6.3 Radio Operations 6.3.1 Radio Control and Calibration Menu [Main menu, Radio Operations] Radio Control and Calibration Menu Current test selection is MEDIUM SYS:yyyy-mm-dd hh:mm 1 2 3 4 5 6 7 TRANSCEIVER SETUP MENU MEASUREMENT SETUP MENU TRANSCEIVER CONTROL AND PRESENTATION MENU CALIBRATION RADIO REGISTER EDITOR ADJUSTMENT SETUP 0. Main menu Choose alternative: Figure 18 Radio Control and Calibration Menu. Alt.
FBTEST REFERENCE MANUAL Alt. 5 RADIO REGISTER EDITOR Displays the Radio Register Editor menu, Figure 43. Alt. 6 ADJUSTMENT Displays the Radio Adjustment menu, Figure 44. Alt. 7 SETUP Displays the Radio Setup menu, Figure 46. BRU1/BRU3 MANUAL, Doc.
(110) 6.3.2 BRU1/BRU3 MANUAL Transceiver Setup Menu [Main menu, Radio Operations, Transceiver Setup] Figure 19 Alt. 1 Transceiver Setup Menu (NUMBER MODE). SELECT NUMBER OR FREQUENCY MODE Displays the Transceiver Setup menu, (Number Mode in Figure 19 or Frequency Mode in Figure 20). This alternative is a toggle function between channel number mode and channel frequency mode. Conversion between these modes is done automatically.
FBTEST REFERENCE MANUAL • 41 (110) DIVERSITY, radio build with diversity function, YES (= 1) or NO (= 0). NUMBER MODE Alt. 2 SET TX CHANNEL NUMBER Displays TX_CHANNEL NUMBER, TXCH = (3840) This alternative sets the transmitter channel number. A check is made to eliminate incorrect channel values. Alt. 3 SET TX POWER Displays SELECT TX_POWER = - 21.0 PRESS Y TO SELECT N TO NEXT [-21.0 (def), -18.0, -15.0, -12.0, -9.0, -6.0, -3.0, 0.0] The transmitter power is set in the following steps: 0.0, -3.0, -6.
(110) Alt. 5 BRU1/BRU3 MANUAL SET RX CHANNEL NUMBER Displays RX_CHANNEL NUMBER, RXCH = (3040) This alternative sets the receiver channel number. A check is made to eliminate incorrect channel values. Alt. 6 SET LOW OUTPUT POWER ALARM LIMIT Displays OUTPUT ALARM LIMIT = (10) This alternative sets the low output power limit. This value is transferred to the signal processor part, where it is checked against the calculated radio value.
FBTEST REFERENCE MANUAL 43 (110) FREQUENCY MODE [Main menu, Radio Operations, Transceiver Setup] Figure 20 Alt. 2 Transceiver Setup Menu (FREQUENCY MODE). SET TX CHANNEL FREQUENCY Displays TX IN Hz, > = 890 000 000: TXFRQ = (939 000 000) This alternative sets the transmitter channel frequency. A check is made to eliminate incorrect channel values. Input frequency values are given in Hz as the channel separation is 12.5 kHz. Alt.3 SET TX POWER Please refer to NUMBER MODE BRU1/BRU3 MANUAL, Doc.
(110) Alt. 4 BRU1/BRU3 MANUAL SET TX MODULATION Please refer to NUMBER MODE Alt. 5 SET RX CHANNEL FREQUENCY Displays RX IN Hz, > = 890 000 000: RXFRQ =(900 000 000) This alternative sets receiver channel frequency. A check is made to eliminate incorrect channel values. Alt. 6 SET LOW OUTPUT POWER ALARM LIMIT Please refer to NUMBER MODE Alt. 7 SET VSWR ALARM LIMIT Please refer to NUMBER MODE BRU1/BRU3 MANUAL, Doc.
FBTEST REFERENCE MANUAL 6.
(110) Alt. 10: BRU1/BRU3 MANUAL SAVE TEST DATA AT STOP A toggle function between “+” (active) and “-” (inactive). This alternative, when active, stores test data when the test period is finished. This allows the operator to compare test data, while making test observations without saving, between the save instances. Alt. 11: SET TEST TIME Displays ENTER TEST_CYCLES (0) The number of test cycles is set, which is translated in to the time domain, if needed. BRU1/BRU3 MANUAL, Doc.
FBTEST REFERENCE MANUAL 6.4.1 47 (110) Transceiver Control and Presentation Menu [Main menu, Radio Operations, Transceiver Control and Presentation] Transceiver Control and Presentation Menu Current test selection is MEDIUM TX: OFF TXCH: 1234 5 6 3840 PF: SYS:yyyy-mm-dd hh:mm 0 TXSEND:OFF SELECT TRANSMITTER ON/OFF SELECT MODULATION ON/OFF SAVE TEST DATA AT STOP SET TEST TIME:0 IS INDEFINITE START LOOK AT PREVIOUS TEST DATA RXCH: 3040 TEST CYCLES = 0 0.
(110) Alt. 3 BRU1/BRU3 MANUAL SAVE TEST DATA AT STOP A toggle function between “ + “ (YES) and “ - “ (NO). Measurement data is saved when the test period is finished. Alt. 4 SET TEST TIME Displays ENTER TEST_CYCLES (10) The test period is set in cycles, which also correspond to time. A sampling rate of about 1 second is selected, but can be changed to a practical value if necessary. Alt. 5 START The start command starts the measurement. Alt.
FBTEST REFERENCE MANUAL 49 (110) Operating conditions: TX: OFF TXCH: 3840 PF: 0 TXSEND: OFF RXCH: 3040 The status line, below the header, indicating the present operating conditions for the transceiver with the following meaning: • TX is the status of the transmitter, either OFF or ON. • TXCH or TXFRQ is the transmitter channel frequency or number. • PF is the transmitter power from 0 to -21 dB in 3 dB steps.
(110) 6.4.2 BRU1/BRU3 MANUAL Radio Calibration Menu [Main menu, Radio Operations, Calibration] Figure 23 Alt. 1 Radio Calibration Menu. BANDGAP CALIBRATION Gives the Bandgap Calibration Menu, Figure 24. Alt. 2 TEMPERATURE SENSOR CALIBRATION Gives the Temperature Calibration Menu, Figure 25. Alt. 3 REFERENCE OCXO CALIBRATION Gives Reference Oscillator OCXO Calibration menu 1, Figure 27. Alt. 4 PF POWER CALIBRATION Gives PF Power Calibration menu 1, Figure 29. BRU1/BRU3 MANUAL, Doc.
FBTEST REFERENCE MANUAL Alt. 5 51 (110) PR POWER CALIBRATION Gives PR Power Calibration menu 1, Figure 31. Alt. 6 VCO MODULATION CALIBRATION Gives VCO Calibration menu 1, Figure 33. Alt. 7 TCXO MODULATION CALIBRATION Gives TCXO Calibration menu 1, Figure 35. Alt. 8 RSSI CALIBRATION Gives RSSI Calibration menu 1, Figure 37. Alt. 9 EEPROM DISPLAY (EDITOR) This alternative selects a function that will display all calibration object values.
(110) 6.4.3 BRU1/BRU3 MANUAL Bandgap Calibration [Main menu, Radio Operations, Calibration, Bandgap Calibration] Bandgap Calibration Current test selection is MEDIUM SYS:yyyy-mm-dd hh:mm CONNECT VOLTMETER TO BANDGAP VOLTAGE SIGNAL BANDGAP REFERENCE SET VALUE IS 128 NUM IS MEASURED VALUE EQUAL TO 2.5 V ? 1 2 3 4 0. INCREMENT DECREMENT SET VALUE MARK FOR STORAGE IN EEPROM Calibration Menu Choose alternative: Figure 24 Bandgap Calibration menu.
FBTEST REFERENCE MANUAL 53 (110) Alt. 3 SET VALUE Displays VALUE (128) The value can be changed by increment, decrement or by set functions. Alt. 4 MARK FOR STORAGE IN EEPROM This alternative indicates that, this calibration object will be saved in EEPROM when the calibration procedure is finished. BRU1/BRU3 MANUAL, Doc.
(110) 6.4.4 BRU1/BRU3 MANUAL Temperature Sensor Calibration [Main menu, Radio Operations, Calibration, Temp. Sensor Calibration] Temperature Calibration SYS:yyyy-mm-dd hh:mm Current test selection is MEDIUM 1 2 SET OFFSET CALIBRATION MODE SET ABSOLUTE CALIBRATION MODE 0. Calibration Menu Choose alternative: _ Figure 25 Temperature Sensor Calibration menu. Alt. 1-2 Will display the Temperature Calibration menu, Figure 26. Alt. 1 Offset mode Alt. 2 Absolute mode BRU1/BRU3 MANUAL, Doc.
FBTEST REFERENCE MANUAL 55 (110) [Main menu, Radio Operations, Calibration, Temp. Sensor Calibration. 2] Temperature Calibration Current test selection is MEDIUM TX: OFF TXCH: 3840 TEMPERATURE A/D VALUE: 141 TEMPERATURE INDEX: 2 T1 T2 TDEG: -8.0 6.0 TNUM: 78 107 1 0 TXSEND:OFF T3 20.0 134 RXCH: T4 34.0 163 2 3 ENTER TEMPERATURE INDEX T1 - T5 FOR OFFSET/ABSOLUTE MODE ENTER CALIBRATION VALUE FOR OFFSET/ABSOLUTE MODE MARK FOR STORAGE IN EEPROM 0. Calibration Menu Figure 26 Alt 1.
(110) 6.4.5 BRU1/BRU3 MANUAL Reference Oscillator OCXO Calibration [Main menu, Radio Operations, Calibration, Reference OCXO Calibration] Reference Oscillator OCXO Calibration SYS:yyyy-mm-dd hh:mm Current test selection is MEDIUM 1 SELECT OFFSET CALIBRATION MODE 2 SELECT ABSOLUTE CALIBRATION MODE 0. Calibration Menu Choose alternative: _ Figure 27 Reference Oscillator OCXO Calibration - 1 menu. Alt. 1-2 Will display the Reference Oscillator OCXO Calibration menus in Figure 28. Alt.
FBTEST REFERENCE MANUAL 57 (110) [Main menu, Radio Operations, Calibration, Reference OCXO Calibration] Reference Oscillator OCXO Calibration Current test selection is MEDIUM TX: OFF TXCH: PF. INDEX: 2 T1 TDEG: -8.0 OCXO: 80 3840 T2 6.0 80 PF: 0 SYS:yyyy-mm-dd hh:mm TXSEND:OFF TEMP INDEX: 2 T3 20.0 81 RXCH: T4 34.0 81 IS OCXO FREQUENCY OK ON EXTERNAL INSTRUMENT ? 1 2 5 6 - 0.
(110) BRU1/BRU3 MANUAL Alt. 4 SET VALUE Sets VALUE (xx) The value can be changed by increment, decrement or by the set function. Alt. 5 MARK FOR STORAGE IN EEPROM After some changes of the old value, the new value can be marked for storage in EEPROM, when the calibration procedure is finished. Alt. 6 SELECT TRANSMITTER ON/OFF A toggle function between “ + “ (ON) and “ - “ (OFF). BRU1/BRU3 MANUAL, Doc.
FBTEST REFERENCE MANUAL 6.4.6 59 (110) PF Output Power Calibration [Main menu, Radio Operations, Calibration, PF Power Calibration] PF Power Calibration Current test selection is MEDIUM SYS:yyyy-mm-dd hh:mm 1 2 SELECT OFFSET CALIBRATION MODE SELECT ABSOLUTE CALIBRATION MODE 0. Calibration Menu Choose alternative: Figure 29 PF Power Calibration menu. Alt. 1-2 Will display the PF Power Calibration menu in the next figure, Figure 30. Alt. 1 Offset mode Alt.
(110) BRU1/BRU3 MANUAL [Main menu, Radio Operations, Calibration, PF Power Calibration] PF Power Calibration Current test selection is MEDIUM TX: OFF TXCH: 3840 PF: PF. INDEX: 2 TDEG PFNUM: PFM: T1 -8.0 108 128 1 PFSET: -21.0 PFNUM: 101 PFM 1 2 3 7 118 0 SYS:yyyy-mm-dd hh:mm TXSEND:OFF RXCH: 3040 TEMP INDEX: 2 T2 6.0 107 126 2 -18.0 107 126 T3 20.0 107 124 3 -15.0 117 137 T4 34.0 107 121 4 -12.0 128 150 T5 48.0 106 117 5 -9.0 141 167 6 -6.0 157 186 7 -3.0 177 211 8 0.
FBTEST REFERENCE MANUAL 61 (110) Alt. 2 ENTER TEMPERATURE INDEX FOR PF IN OFFSET/ ABSOLUTE MODE Displays TEMPERATURE INDEX (2) Alt. 3 INCREMENT Increases the value in steps. Alt. 4 DECREMENT Decreases the value in steps. Alt. 5 SET VALUE Displays VALUE (x) The alternatives, if the temperature check was OK, modify the output reference value. The measured output power on the external instrument is calibrated to the defined nominal value for the selected PF index.
(110) 6.4.7 BRU1/BRU3 MANUAL PR Reflected Power Calibration [Main menu, Radio Operations, Calibration, PR Power Calibration] PR Power Calibration Current test selection is MEDIUM SYS:yyyy-mm-dd hh:mm 1 2 SELECT OFFSET CALIBRATION MODE SELECT ABSOLUTE CALIBRATION MODE 0. Calibration Menu Choose alternative: Figure 31 PR Power Calibration - 1 menu. Alt. 1-2 Will display PR Power Calibration menu 2, Figure 32. Alt. 1 Offset mode Alt. 2 Absolute mode BRU1/BRU3 MANUAL, Doc.
FBTEST REFERENCE MANUAL 63 (110) [Main menu, Radio Operations, Calibration, PR Power Calibration] Figure 32 Alt. 1 PR Power Calibration - 2 menu. SELECT TX POWER INDEX P1-P8 FOR OFFSET/ABSOLUTE MODE Displays SELECT TX_POWER = -21.0 PRESS Y TO SELECT N TO NEXT [-21.0 (def), -18.0, -15.0, -12.0, -9.0, -6.0, -3.0, 0.0] Alt.
(110) Alt. 4 BRU1/BRU3 MANUAL MARK FOR STORAGE IN EEPROM This alternative indicates that this calibration object will be saved in EEPROM when the calibration procedure is finished. Alt. 5 SELECT TRANSMITTER ON/OFF A toggle function between “ + “ (ON) and “ - “ (OFF). Alt. 6 SLOT NUMBER [1-2] Displays the selected slot number. Enter the desired slot number Alt.
FBTEST REFERENCE MANUAL 6.4.8 65 (110) VCO Modulation Calibration [Main menu, Radio Operations, Calibration, VCO Calibration] VCO Calibration Current test selection is MEDIUM 1 2 0. SYS:yyyy-mm-dd hh:mm SELECT OFFSET CALIBRATION MODE SELECT ABSOLUTE CALIBRATION MODE Calibration Menu Choose alternative: _ Figure 33 VCO Calibration - 1 menu. Alt. 1-2 Will display the VCO Calibration menu 2, Figure 34. BRU1/BRU3 MANUAL, Doc.
(110) BRU1/BRU3 MANUAL [Main menu, Radio Operations, Calibration, VCO Calibration] VCO Calibration Current test selection is MEDIUM TX: OFF TXCH: TEMP INDEX: 2 T1 TDEG: -8.0 VCO: 212 1 2 5 6 7 8 9 10 0. - 3840 PF: SLOT: T2 6.0 201 SYS:yyyy-mm-dd hh:mm 0 1 TXSEND:OFF CHANNEL: T3 20.0 189 RXCH: 3800 T4 34.0 182 3040 T5 48.
FBTEST REFERENCE MANUAL Alt. 3 67 (110) DECREMENT Decreases the value in steps. Alt. 4 SET VALUE Displays SET VCO (201) The value can be changed by increment, decrement or by set functions. Alt. 5 MARK FOR STORAGE IN EEPROM This alternative indicates that this calibration object will be saved in EEPROM when the calibration procedure is finished. Alt. 6 SELECT TRANSMITTER ON/OFF This alternative is a toggle function between “+” (ON) and “-” (OFF). Alt.
(110) Alt. 9 BRU1/BRU3 MANUAL SELECT SLOT Displays SLOT NUMBER [1-3] (1) 34xx: For each slot the calibration has to be done at three different frequencies. The frequency band, selected in the “Radio Operation Parameters in menu” in Figure 23, shall be divided into the current number of slots. The number of slots is determined by the total frequency band covered by the BRU3 variant. 38xx and 39xx: The calibration is done at one frequency. Enter SLOT NUMBER = 1. Alt.
FBTEST REFERENCE MANUAL 6.4.9 TCXO Modulation Calibration [Main menu, Radio Operations, Calibration, TCXO Calibration] TCXO Calibration Current test selection is MEDIUM SYS:yyyy-mm-dd hh:mm 1 2 SELECT OFFSET CALIBRATION MODE SELECT ABSOLUTE CALIBRATION MODE 0. Calibration Menu Choose alternative: Figure 35 TCXO Calibration - 1 menu. Alt. 1-2 Displays TCXO Calibration menu 2, Figure 36. BRU1/BRU3 MANUAL, Doc.
(110) BRU1/BRU3 MANUAL [Main menu, Radio Operations, Calibrations, TCXO Calibration] TCXO Calibration Current test selection is MEDIUM TX: OFF TXCH: 3840 PF: SYS:yyyy-mm-dd hh:mm 0 TXSEND:OFF RXCH: 3040 TEMP INDEX: 2 TDEG: TCXO: 1 T1 -8.0 234 T2 6.0 234 T3 20.0 234 T4 34.0 234 T5 48.
FBTEST REFERENCE MANUAL Alt. 1 71 (110) ENTER TEMPERATURE INDEX T1-T5 FOR OFFSET/ ABSOLUTE MODE Displays TEMPERATURE INDEX (2) The temperature index is selected and the temperature check, as described for temperature calibration, is initiated. Alt. 2 INCREMENT Increases the value in steps. Alt. 3 DECREMENT Decreases the value in steps. Alt. 4 SET VALUE Display SET TCXO (215) If the temperature check was OK these alternatives modify the output gain value.
(110) Alt. 7 BRU1/BRU3 MANUAL SELECT MODULATION Selects the modulation Displays SELECT MODULATION = NONE SELECT NO FOR NEXT PRESS Y TO [NONE (default), AC, LOW, HIGH, PRBS, PERIOD, SINE] Alt. 8 SELECT MODULATION ON/OFF This function is a toggle function between “+” (ON) and “-” (OFF). Alt. 9 VCO MODULATION ON/OFF This function is a toggle function between “+” (ON) and “-” (OFF). BRU1/BRU3 MANUAL, Doc.
FBTEST REFERENCE MANUAL 6.4.10 73 (110) RSSI Calibration [Main menu, Radio Operations, Calibration, RSSI Calibration] RSSI Calibration Current test selection is MEDIUM TX: OFF TXCH: RSSI INDEX: 2 T1 T2 TDEG: -7.0 3.0 RSSI: 85 108 3840 T3 13.0 126 T4 23.0 143 PF: T5 33.0 164 SYS:yyyy-mm-dd hh:mm 0 TXSEND:OFF T6 43.0 169 T7 53.0 169 T8 63.0 167 RXCH: 3040 T9 T10 73.0 83.
(110) BRU1/BRU3 MANUAL Alt. 1 SELECT RSSI INDEX S1-S10 FOR OFFSET/ABSOLUTE MODE Displays RSSI SIGNAL INDEX (2) The RSSI index is selected. The measured RSSI value is entered at reference index point, when the signal strength is set to the defined value at the external instrument. Alt. 2 READ AND ENTER CALIBRATION VALUE Alt 3 MARK FOR STORAGE IN EEPROM This alternative indicates that this calibration object will be saved in EEPROM when the calibration procedure is finished. BRU1/BRU3 MANUAL, Doc.
FBTEST REFERENCE MANUAL 6.4.11 75 (110) EEPROM Display Editor Menu [Main menu, Radio Operations, Calibration, EEPROM Display Editor-1] Figure 38 Alt.1 EEPROM Display menu - screen 1. SELECT SCREEN 1 This menu BRU1/BRU3 MANUAL, Doc.
(110) BRU1/BRU3 MANUAL Alt. 2 SELECT SCREEN 2 [Main menu, Radio Operations, Calibration, EEPROM Display Editor-2] Figure 39 EEPROM Display menu - screen 2. BRU1/BRU3 MANUAL, Doc.
FBTEST REFERENCE MANUAL Alt. 3 77 (110) SELECT SCREEN 3 [Main menu, Radio Operations, Calibration, EEPROM Display Editor-3] Figure 40 EEPROM Display menu - screen 3. BRU1/BRU3 MANUAL, Doc.
(110) BRU1/BRU3 MANUAL Alt. 4 SELECT SCREEN 4 [Main menu, Radio Operations, Calibration, EEPROM Display Editor-4] Figure 41 EEPROM Display menu - screen 4. BRU1/BRU3 MANUAL, Doc.
FBTEST REFERENCE MANUAL 6.4.12 79 (110) PA Bias and FDAC Calibration Menu [Main menu, Radio Operations, Calibration, PA Bias and FDAC Calibration] Figure 42 Alt. 1 PA Bias and FDAC Calibration Menu. SET PA BIAS DRIVER Shows the current setting of the driver bias (a). Alt. 2 SET PA BIAS FINAL Shows the current setting of the final bias (a). Alt. 3 SET FDAC RX Shows the current setting of the Rx syntheziser (a). Alt. 4 SET FDAC TX Shows the current setting of the Tx syntheziser (a).
(110) Alt. 5 BRU1/BRU3 MANUAL SETUP RADIO OPERATION PARAMETERS Shows the current setting of the radio operation parameters (a). Alt. 6 SELECT TRANSMITTER ON/OFF Shows the current setting of the transmitter (a). Alt. 7 SAVE PA BIAS AT LOW POWER SLOT Saves the current setting of PA BIAS at low power slot. Alt. 8 SAVE PA BIAS AT HIGH POWER SLOT Saves the current setting of PA BIAS at high power slot. (a) When a new value is entered it takes effect on the radio board immediately.
FBTEST REFERENCE MANUAL 6.4.13 81 (110) Radio Register Editor Menu [Main menu, Radio Operations, Radio Register Editor] Radio Register Editor Menu Current test selection is MEDIUM 1 2 READ RADIO REGISTER WRITE RADIO REGISTER 0. Previous Menu SYS:yyyy-mm-dd hh:mm Choose alternative: _ Figure 43 Alt. 1 Radio Register Editor Menu. READ RADIO REGISTER Displays “ADDRESS = (1)”. enabling reading of the address number. Alt. 2 WRITE RADIO REGISTER Displays “ADDRESS = (1)”.
(110) 6.4.14 BRU1/BRU3 MANUAL Adjustment [Main menu, Radio Operations, Adjustment] Radio Adjustment Menu Current test selection is MEDIUM SYS:yyyy-mm-dd hh:mm 1 2 OCXO AGE ADJUSTMENT SAVE ADJUSTMENT IN EEPROM 0. Radio Control and Calibration Menu Choose alternative: _ Figure 44 Alt. 1 Radio Adjustment Menu. OCXO AGE ADJUSTMENT Displays the menu in Figure 45. Alt. 2 SAVE ADJUSTMENT IN EEPROM Saves the adjustment in EEPROM. BRU1/BRU3 MANUAL, Doc.
FBTEST REFERENCE MANUAL 83 (110) [Main menu, Radio Operations, Adjustment, OCXO Age Adjustment] OCXO Age Adjustment Menu Current test selection is MEDIUM SYS:yyyy-mm-dd hh:mm CURRENT ADJUSTMENT VALUE IS 0 1 2 3 4 INCREMENT DECREMENT SET VALUE MARK FOR STORAGE IN EEPROM 0. Adjustment menu Choose alternative: _ Figure 45 Alt. 1 OCXO Age Adjustment Menu. INCREMENT Increases the CURRENT ADJUSTMENT VALUE in steps. Alt. 2 DECREMENT Decreases the CURRENT ADJUSTMENT VALUE in steps. Alt.
(110) Alt. 4 BRU1/BRU3 MANUAL MARK FOR STORAGE IN EEPROM This alternative indicates that this calibration object will be saved in EEPROM when the calibration procedure is finished. BRU1/BRU3 MANUAL, Doc.
FBTEST REFERENCE MANUAL 6.4.15 85 (110) Setup [Main menu, Radio Operations, Setup] Figure 46 Alt. 1 Radio Setup Menu. FREQUENCY BAND A toggle function between 400-1, 400-2, 800, 819 and 900 MHz. This alternative is used to choose between the 400-1 and 400-2 MHz, 800 and 819 MHz and 900 MHz bands. 400-2 equals the UK National frequency band. 400-1 equals all other 400 MHz frequency bands including the UK City frequency band.
(110) Alt. 3 BRU1/BRU3 MANUAL RADIO BOARD ROA Toggles radio board between: Alt. 4 • Unknown (old) • ROA 1179842/1 (900 MHz) • ROA 1179842/3 (800 MHz) • ROA 117 8897 (400 MHz) RADIO BOARD ROA REVISION Sets radio board revision number Alt. 5 DEFAULT TX CHANNEL NUMBER Displays DISPL. TX CHAN. (3840) Sets the transmitter channel number. Alt. 6 DEFAULT RX CHANNEL NUMBER Displays DISPL. RX CHAN. (3040) Sets the receiver channel number. Alt.
FBTEST REFERENCE MANUAL 6.5 87 (110) Modem Operation Menu (BRU3 only) [Main menu, Modem Operations] Modem Operation SYS:yyyy-mm-dd hh:mm Current test selection is MEDIUM 1. 2. 3. 4. Line Speed on Modem port DTR status RTS status Transparent Mode access 0. Main menu 9600 OFF OFF Choose alternative: Figure 47 Alt. 1 Modem Operation menu.
(110) 6.6 BRU1/BRU3 MANUAL Interface Board Parameters Menu (BRU1 only) [Main menu, Interface Board Parameters] Figure 48 Interface Board Parameters menu (BRU1 only). Alt. 1 SERIAL PORT IN USE In BRU1 the serial port in use is set here, instead of the strap used in BRU3. Alt. 2 ETHERNET DUPLEX Sets Ethernet duplex. Alt. 3 DISPLAY CONFIGURATION DATA Displays the “Configuration Data Display” in Figure 49. BRU1/BRU3 MANUAL, Doc.
FBTEST REFERENCE MANUAL 6.6.1 89 (110) Configuration Data Display [Main menu, Interface Board Parameters, Display Configuration Data] Figure 49 Configuration Data Display menu. (BRU1 only) BRU1/BRU3 MANUAL, Doc.
(110) 6.7 BRU1/BRU3 MANUAL Status Overview Menu [Main menu, Status Overview] Figure 50 Status Overview menu (BRU3). Figure 50 “Status Overview menu (BRU3).” and Figure 51 “Status Overview menu (BRU1).” shows an example of the Status Overview menu. Status Line “DAA Status” will display the current country code. BRU1/BRU3 MANUAL, Doc.
FBTEST REFERENCE MANUAL Figure 51 Status Overview menu (BRU1). BRU1/BRU3 MANUAL, Doc.
(110) 6.8 BRU1/BRU3 MANUAL Edit Loader Parameters Menu (BRU3 and System Release R14 only) [Main menu, Edit Loader Parameters] Edit Loader Parameters Current test selection is MEDIUM 1. 2. 3. 4. 5. 6. Node 0 Ports Channels Connections Read parameters from Flash Store parameters to Flash 0. Main menu SYS:yyyy-mm-dd hh:mm Choose alternative: Figure 52 Note: Alt. 1 Edit Loader Parameters menu. Normally, an edit session starts with the selection of alt 5.
FBTEST REFERENCE MANUAL Alt. 2 PORTS Displays the “Define Ports menu” in Figure 53. Alt. 3 CHANNELS Displays the “Define Channels menu” in Figure 59. Alt. 4 CONNECTIONS Displays the “Define Connections menu” in Figure 62. Alt. 5 READ PARAMETERS FROM FLASH Reads the parameters stored in flash. Alt. 6 STORE PARAMETERS TO FLASH Saves the parameters in FLASH. BRU1/BRU3 MANUAL, Doc.
(110) 6.8.1 BRU1/BRU3 MANUAL Ports [Main menu, Edit Loader Parameters, Ports] Define ports Current test selection is MEDIUM 1. 2. Port Not in use : 0. Previous menu SYS:yyyy-mm-dd hh:mm 1 Choose alternative: Figure 53 Alt. 1 Define Ports - “Not in use” menu. PORT Displays Port number [1-1]:(1) The desired physical port can only be set to “1” as only one port is available on the BRU3. Alt. 2 NOT IN USE Selects between “Not in use” or “In use” by toggling.
FBTEST REFERENCE MANUAL 95 (110) [Main menu, Edit Loader Parameters, Ports] Define ports SYS:yyyy-mm-dd hh:mm Current test selection is MEDIUM 1 2 3 4 5 6 Port In use Unit number Local port number Modem parameters X25 parameters 0. Previous menu : 1 : 0 : 1 Choose alternative: _ Figure 54 Alt. 1 Define Ports - “In use” menu. PORT Choose alternative: Port number [1 - 1]: (1) Alt. 2 IN USE Selects between “Not in use” or “In use” by toggling. The select “In use” displays the menu in Figure 54.
(110) Alt. 4 BRU1/BRU3 MANUAL LOCAL PORT NUMBER Choose alternative: Local port number [1 - 1] (1) As only one local port is available on the node, the set value should be “1”. Alt. 5 MODEM PARAMETERS Displays the Port - Modem Parameter menu in Figure 55. Alt. 6 X.25 PARAMETERS Displays the Port - X.25 Parameter menu in Figure 58. BRU1/BRU3 MANUAL, Doc.
FBTEST REFERENCE MANUAL 97 (110) [Main menu, Edit Loader Parameters, Ports, Modem Parameters] Define modem parameters Current test selection is MEDIUM 1 2 3 4 5 6 7 8 Modem in use Control type Prompt Bitrate Dial timeout Answer timeout Init commands Dial commands 0. Previous menu : : : : : : SYS:yyyy-mm-dd hh:mm YES ATHAYES OK 9600 60 60 Choose alternative: Figure 55 Alt. 1 Edit Modem Parameters menu. MODEM IN USE A toggle function between YES or NO. Alt.
(110) Alt. 4 BRU1/BRU3 MANUAL BIT RATE A toggle function between bit rates 1200, 2400, 4800, 9600 and 14400, where the bit rate normally should be set to 9600, but it is possible to select other rates by toggling. Note: This bit rate setting is related to asynchronous communication (sending initiation commands to the modem). Alt. 5 DIAL TIMEOUT The Dial Timeout in seconds should be entered. Dial timeout [sec][0 - 500]: (0) The value should normally be 60 sec. Alt.
FBTEST REFERENCE MANUAL Alt. 8 99 (110) DIAL COMMANDS Displays the 10 Dial Command sequences, please refer to the menu in Figure 57. [Main menu, Edit Loader Parameters, Ports, Modem Parameters, Init Commands] Modem Initial Command for Port 1 Current test selection is MEDIUM 1 2 3 4 5 Command Command Command Command Command 1 2 3 4 5 : : : : : 0. Previous menu SYS:yyyy-mm-dd hh:mm ATE0 AT&D2 AT&M1 Choose alternative: _ Figure 56 Note: Edit Modem Parameters menu, Init Commands.
(110) BRU1/BRU3 MANUAL [Main menu, Edit Loader Parameters, Ports, Modem Parameters, Dial Commands] Modem Dial Command for Port 1 Current test selection is MEDIUM 1 2 3 4 5 6 7 8 9 10 SYS:yyyy-mm-dd hh:mm : ATD543301 : ATD543302 : : : : : : : : 1 2 3 4 5 6 7 8 9 10 Command Command Command Command Command Command Command Command Command Command 0. Previous menu Choose alternative: _ Figure 57 Edit Modem Parameters menu, Dial Commands. BRU1/BRU3 MANUAL, Doc.
FBTEST REFERENCE MANUAL 101 (110) [Main menu, Edit Loader Parameters, Ports, X.25 Parameters] X25 parameters for port 1 Current test selection is MEDIUM 1 2 3 4 5 6 7 8 Local address Packet size Window size Bitrate Ltc channel Htc channel Network Network ID 0. Previous menu : : : : : : : : SYS:yyyy-mm-dd hh:mm 1 512 2 9600 bps 1 8 X25 Network 255 Choose alternative: Figure 58 Alt 1. Edit X.25 Parameters menu. Enter the LOCAL ADDRESS: Enter your own X.25 address. Alt 2.
(110) 6.8.2 BRU1/BRU3 MANUAL Channels Alt. 3 “Channels” in the Edit Loader Parameters Menu displays the following menu: [Main menu, Edit Loader Parameters, Channels] Define channels SYS:yyyy-mm-dd hh:mm Current test selection is MEDIUM 1. 2. Channel Not in use : 1 0. Previous menu Choose alternative: _ Figure 59 Define Channels menu. If alternative 1 is selected, the “Choose alternative” will change to: Channel number [1 - 5]: (1). BRU1/BRU3 MANUAL, Doc.
FBTEST REFERENCE MANUAL 103 (110) [Main menu, Edit Loader Parameters, Channels] Define channels SYS:yyyy-mm-dd hh:mm Current test selection is MEDIUM 1. 2. 3. 4. 5. Channel In use Port Local channel number X.25 Parameters 0. Previous menu : 1 : : 1 1 Choose alternative: _ Figure 60 Define Channels menu. Alt 1. Enter the Channel number [1 - 5]:(1), select the channel number to be edited. Alt 3. Enter the Port number [1 - 1]:(1) Alt 4. Enter the Local channel number [0 - 255]:(1) Alt 5.
(110) BRU1/BRU3 MANUAL [Main menu, Edit Loader Parameters, Channels, X.25 Parameters] X.25 parameters for channel 1 Current test selection is MEDIUM 1. 2. 3. 4. 5. 6. 7. 8. Remote address Packet size Window size Connection type Logical channel Request rev chg Accept rev chg Accept empty addr : : : : : : : : SYS:yyyy-mm-dd hh:mm 00000 128 2 VC -1 No Yes No 0. Previous menu Choose alternative: _ Figure 61 X.25 Parameters for Channel 1 menu. Alt 1.
FBTEST REFERENCE MANUAL 6.8.3 105 (110) Connections Alt. 4 “Connections” in the Edit Loader Parameters Menu displays the following menu: [Main menu, Edit Loader Parameters, Connections] Define connections Current test selection is MEDIUM 1. 2. Connection Not in use : 0. Previous menu SYS:yyyy-mm-dd hh:mm 1 Choose alternative: Figure 62 Define Connection menu. Alt 1. Enter the Connection number [1 - 5]:(1) Alt 2. A choice between NOT IN USE and IN USE.
(110) BRU1/BRU3 MANUAL [Main menu, Edit Loader Parameters, Connections] Define connections Current test selection is MEDIUM 1. 2. 3. 4. 5. Connection In use Remote node Priority Channel 0. Previous menu : 1 : : : 0 0 1 Choose alternative: Figure 63 SYS:yyyy-mm-dd hh:mm _ Edit Loader Parameters menu - selection of connection. Alt 1. Enter the Connection number [1 - 5]:(0) Alt 2. Enter the Remote node number [0 - 99999]:(0) Alt 3. Enter the Priority [0 - 255]:(0) Alt 4.
FBTEST REFERENCE MANUAL 6.8.4 107 (110) Read Parameters from FLASH [Main menu, Edit Loader Parameters, Read Parameters from FLASH] Edit loader parameters Current test selection is MEDIUM 1 2 3 4 5 6 Node XXXXX Ports Channels Connections Read parameters from Flash Store parameters to Flash 0. Main menu SYS:yyyy-mm-dd hh:mm Choose alternative: Figure 64 Edit Loader Parameters menu - selection of parameters. Alt 1. Enter your own node number [0 - 9999]: (xxxxx) Alt 2.
(110) 6.8.5 BRU1/BRU3 MANUAL Store Parameters in FLASH The messages “Storing data in Flash”, followed by “Data stored successfully in Flash” will be briefly displayed. The menu will then return to normal display: [Main menu, Edit Loader Parameters, Store Parameters in FLASH] Edit loader parameters Current test selection is MEDIUM 1 2 3 4 5 6 Node XXXXX Ports Channels Connections Read parameters from Flash Store parameters to Flash 0.
FBTEST REFERENCE MANUAL 109 (110) Index Adjustment Menu Bandgap Calibration Menu Board Test Menu Channels Menu Connections Menu Edit Loader Parameters Menu EEPROM Display Editor Menu Frequency Mode Menu Interface Configuration Menu Main Menu Measurement Setup Menu Modem Operation Menu Modem Parameters Menu Number Mode Menu OCXO Age Adjustment Menu PA Bias and FDAC Calibration Menu PF Output Power Calibration Menu PF Reflected Power Calibration Menu Radio Calibration Menu Radio Control and Calibration Menu
(110) X.25 Parameters Menu BRU1/BRU3 MANUAL 101, 104 BRU1/BRU3 MANUAL, Doc.