User's Manual Part 3

RBS 2109 User’s Guide
P010476A
Figure 66 Reading Fault Status
3. In the Available monitors box, select ‘MO fault maps’’ and click to add
‘‘RBS’’ into the Monitors to start box.
4. Click Start monitor.
5. In the RBS Event Monitor window, check the MO faults box to see if there
are any faults. If there are, then correct these before continuing.
When an MO fault is selected, corresponding fault description, action and
related faults are displayed. See also Appendix Fault List.
6. Close the RBS Event Monitor window.
7.8 Testing External Alarms
This section describes how to use the OMT to test that all external alarms, if
used, are recognized and handled correctly. The test is passed when all alarms
are recognized.
1
36
E
N/LZT 720 0090 Uen R1A 2004-09-17