211/1212/1311/1312
CONTENTS 3 Product and personal safety guidelines 8 Regulatory information 11 About EARU 1211/1212/1311/1312 16 Checking package contents 17 Installing EARU 1211/1212/1311/1312 25 Setting EARU 1211/1212/1311/1312 26 Open Source Software Notice
Product and personnel safety guidelines This section contains safety guidelines that you must follow for personal safety and to operate the equipment correctly. LG-Ericsson documentation contains precautionary messages and safety procedures that refer to specific tasks or conditions. You must read and follow all precautionary messages before you start to work on the equipment.
Safety standards LG-Ericsson products conform to all relevant safety standards.
Handling optical fibers When you work with optical fibers, you must take the following general precautions: • Wear safety glasses when you install optical fibers. • Do not look into the opening of an optical fiber, or the opening of an optical fiber connector, if the optical fiber is active or the unit has the power turned on. • Avoid direct exposure to optical fiber ends or optical connector ends where you can access the laser signal directly. • Clean your hands after you handle optical fibers.
Repairing optical fibers When an accidental break occurs in the optical fiber, do the following: • Report the location of the damaged optical fiber to both the service provider and the field repair personnel. • Power down all laser sources to the optical fiber or disconnect the remote optical fiber end from the laser sources.
CAUTIONS Warranty: Customers can receive repair services for this product under specified conditions. This warranty does not cover failure or damage of the product caused from, using a power adapter other than the one provided, PC failures, data loss, or negligent treatment of the product.
Regulatory information This chapter contains the following information: • a list of global technical standards (electromagnetic compatibility, safety) to which the EARU 1211/1212/1311/1312 complies. • a country-by-country list of specific regulatory text required by national authorities • information on the regulatory labels affixed to the product (artwork and location on the product) The list of global technical standards provided in this chapter is not exhaustive.
Country-specific regulatory information Canada This Class B digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada. United States of America This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
• EN 300 386 V1.4.
The product bears the CE mark as illustrated in figures on page14. A signed Declaration of Conformity is available upon request. Brazil The EARU 1211/1212/1311/1312 conforms with the requirements of Anatel Resolution Number 442:2006 (EMC) for a Class B product and Anatel Resolution NR 238:2000 for product safety. Japan (English translation) This is a Class B product based on the standard of the Voluntary Control Council for Interference from Information Technology Equipment (VCCI).
About EARU 1211/1212/1311/1312 Thank you for selecting EARU 1211/1212/1311/1312. The EARU 1211/1212/1311/1312 is an equipment working as a modem in WDM-PON (Wavelength Division Multiplexing - Passive Optical Network). This product multiplexes 1250Mbps to 1000Mbps Ethernet signals (maximum 4ea) into WDM-PON optical signal. This product will allow you to use the different services such as VoD (Video on Demand), EoD (Education on Demand), IP-TV, POTS and High speed internet access available from your provider.
Bottom view EARU 1211 ⑧ EARU 1212 EARU 1311 EARU1312 ⑦ ⑪ ⑨ ⑩ ⑥
LEDs and Port functions Number Indicator Usage Color Power ① PWR STS ② display ON : Power OK and normal status Green Blink : Firmware Downloading Status display Function ON : Alarm event Red Blink (by turns) : CPU booting ①+② Blink (at once) : Main application loading Combina Green OFF, Red ON : Boot Fail tion Green OFF, Red OFF : Check power supply Network L ③ WAN ON : Link ON Display E Green Blink : Activity D Ethernet ④ LAN ON : Link Green Blink : activity display ⑤ TEL POTS O
Labels ① ③ ② Number item Label Location PEC & SN Label 1 Rear 9.652mm x 27.94mm Hazard level 1 2 (per IEC 60825-2) Front 9.5mm x 15mm Regulatory 3 Rear 17.04mm x 80.
Specifications Item Dimensions in mm Power Ambient Temperature Humidity Specification 224.4(w) x 230.
Checking package contents Before installing this product, ensure all parts are provided. Checking what is in the package Check the package to make sure the following items are included. EARU 1211/1212/1311/1312 Main body User manual Pedestal (for desktop mounting (option)) Wall mounting kit (Option) No. Item Name Quantity Item Number 1 WALL MOUNTING PANEL 1 N04697-00 2 SCREW(BN82429-3-8) 4 P04932-00 3 SCREW(BN695-5.
Installing EARU 1211/1212/1311/1312 This section provides the specifications for EARU 1211/1212/1311/1312 installation, it also describes how to install it and connect it into a network. Installation environments Install the EARU 1211/1212/1311/1312 in an environment where the following specifications are met. - Operating temperature: 0℃ to 40℃(@EARU121x), 0℃ to 50℃(@EARU131x) - Relative humidity: 20% to 80% - Power consumption: Max 10.
Installing the product Mounting method Only use these two types of mounting methods. Other mounting types will not work properly. Desktop mounting Step1. Insert the lower side projections of the pedestal to the lower side holes of main body.
Step2. Push upper side projections of pedestal toward the upper side holes of main body till they join.
Wall mounting Step 1: Drill anchor holes through the wall with a drill bit (diameter 8mm) to minimum 38mm depth. Step 2: Insert the SPRIAL PLASTIC PLUGs into the hole. Step 3: Insert the supplied screws through the WALL MOUNTING PANEL and screw them into the PLUGs. Step 4: Hang the EARU 1211/1212/1311/1312 BODY on the WALL MOUNTING PANEL. No. Item Name Quantity Item Number 1 WALL MOUNTING PANEL 1 N04697-00 2 SCREW(BN82429-3-8) 4 P04932-00 3 SCREW(BN695-5.
Connecting optical cable (@EARU 1211, 1212) Check that the power is off. Insert the SC APC connector into the optical port of the EARU 1211 or 1212 . Insert the other end of the APC optical cable into the optical outlet on your wall. SC APC Optical cable at the EARU 1211 and Connecting SFP module (@EARU 1311, 1312) Check that the power is off. Insert the SFP module into the SFP port of the EARU 1311 or 1312.
Fiber cable Management Route fiber drop cable. Step 1 : Determine the cable entry location. Unfasten 2 screws on the storage cover of EARU 1211/1212/1311/1312 and open it. Cable exit location Step 2 : Cable can only enter the slack storage device from the lower left slot. Route the cable (about 2m) in the slack storage device in a clockwise direction.
Step 3 : The fiber drop cable must exit the slack storage devicefrom the uper, right or left slot. Step 4 : Leave enough fiber drop cable extending from the slack storage device to allow for a drip loop when connected to EARU 1211/1212/1311/1312 unit. Step 5 : Fasten 2 screws on the storage cover of EARU 1211/1212/1311/1312.
Connecting Ethernet cable Connect Ethernet cables to the RJ45 Ethernet port numbered 1 to 4 in EARU 1211/1212/1311/1312. Connect the other side of the Ethernet cable to the Ethernet port of your home device.
Connecting Telephone cable Connect Telephone cables to the RJ11 POTS port numbered 1 to 2 in EARU 1212 or 1312. Connect the other side of the POTS cable to the POTS port of your home telephone. CAUTION All of Ethernet and POTS(Tel Line) cables from EARU should be connected only to in-house and in-building without direct routing to the outside plant.
Connect the DC Power Adapter to the Power connection Make sure that both ends of the optical cable and the Ethernet cables are installed. And insert the connector of adapter into the port of the EARU 1211/1212/1311/1312. Make sure that the PWR LED (green) turns on. Power connection Power Adapter The cable cover always should be installed with correct position after insertion all cables into the ports of EARU 1211/1212/1311/1312.
Checking the connection status Checking the connection status of service provider line (Link) When the EARU 1211/1212/1311/1312 is first powered on, the STS LED should turn red momentarily. Once communication is established, this LED turns off. The LAN LED should turn green and blink. STS LED LAN LED Checking the connection status of user devices When EARU 1211/1212/1311/1312 is power-fed, the Green and Orange LEDs should be on. The green LED is the data indicator.
Setting EARU 1211/1212/1311/1312 When you select to receive WDM-PON service, you do not have to make additional settings on the product to use it. Using Internet With a web browser such as the Internet Explorer on your PC, you can surf freely through the Internet. Note EARU 1211/1212/1311/1312 does not require any access program. Use your regular internet browser.
Open Source Software Notice The following open source software used in this product: o o o o o o o o o o uclibc 0.9.29 MIPS Linux kernel, version 2.6 STP bridge in kernel BusyBox 1.0.0 toolset iptables‐1.3.8 Telnet server, login Ftp server: bftpd 1.0.24 Tcpdump and libpcap dproxy: dproxy‐nextgen Iproute2: iproute2‐2.4.
Copyright © 2010 LG-Ericsson Co., Ltd. All Rights Reserved. Copyright of this manual belongs to LG-Ericsson Co., Ltd. Reproduction, distribution or revision of part or all of contents in this manual in any form without written permission of LG-Ericsson Co., Ltd. is prohibited. The information in this manual is subject to change for the reason of function improvement, design alteration, etc. without any prior notification. http://www.lgericsson.com P/N : SM0-000-S00529 Feb/2011/Ver 1.