Wireless Keypad KP700
CONTENTS 1. INTRODUCTION Introduction Package Contents Features 1 1 2 2. BEFORE USE Power On Connecting Installation 3 4,5 5 3. SETTINGS Enter setup state Exit Delay SOS key Keyboard Tone RFID reader setting Direct disarm by RFID tag Change user code Change admin code Reset 6 6,7 7 8 8,9 9,10 10,11 11 11 4. USAGE Arm Disarm Stay mode Emergency Call Mute Mode 12 12,13 13 14 14 5. NOTICES & MAINTENANCE Usage notices Maintenance 15 15 6. FAQ 16 7. INSTRUCTIONS OF WIRED CABLES INTERFACE 17 8.
1.INTRODUCTION Thank you for purchasing this wireless keypad. This can be installed inside or outside the home and allows the user to arm, disarm alarm after inputting passcode. This keypad can also connect to an automatic door lock. KIT CONTENTS Keypad x 1 AAA 1.5V battery x 3 Screws x 4 Manual x 1 Wired cable x1 Note: RFID tags (125KHz) can be purchased separately. Max. 50 pieces are supported.
FEATURES LED indicator RFID reader Arm Disarm Stay mode RFID wake-up key SOS key Positive & negative terminals for battery AAA + + Battery compartment Tamper switch Wired cable interface Note: The keypad beeps twice every two seconds & LED indicator flashes once in case of low battery.
2.BEFORE USE POWER ON Remove the insulating strip for the first time. Keypad uses 3x AAA batteries. AAA + + 1 1 2 3 2 3 Loose the screw, open the case Put batteries in according to the positive and negative signs. Close the rear cover and screw on.
CONNECTING CONNECTING KEYPAD TO CONTROL PANEL Make sure the control panel is in connecting state, input user code 1 or admin code 2 on keypad, and then press any key of [Arm] [Disarm] [Stay Mode]. The connection succeeds after one beep. 1 2 Default User Code: 1234 Default Admin Code: 123456 User can remotely control the panel via the keypad after connection; for detailed connection steps, please refer to the user manuals of panels.
Note: Wrong input for 6 times continuously, the keypad will be locked for 20 seconds. 3 Put RFID tag close to the RFID reader, the connection succeeds after one beep and the LED indicator goes out. 3 If two beeps are heard, it indicates the RFID tag has been connected before. To clear the connection of RFID tags, input [admin code + #] to wake up the keypad and then press down [9] for six seconds. RFID tags are all cleared after one beep.
3.SETTINGS The keypad should enter setup state before all settings. ENTER SETUP STATE 1 1 2 2 Input [admin code + #] to wake up keypad. Press [3] to enter setup state, the LED indicator is on. Under setup state, if there is no operation within 10 seconds, the keypad will exit setup state automatically. You can also press [#] to exit. EXIT DELAY The exit delay allows time to leave after arming the system. After the delay time, if you are sill at home, you may trigger an alarm.
When one beep is heard and the LED indicator keeps on for 10 seconds, the setup is successful. Once the delay time is set, when you arm the keypad, it will beep once every two seconds to remind you to leave. The reminding rhythm will speed up in the last 15 seconds. After the delay time, the control panel enters arm state. Note: User can input digital 0-250 which refers to 0-250 seconds. Default setting: 0, no delay. SOS KEY You can choose to input code before pressing [SOS] key or not.
KEYBOARD TONE Keyboard tone can be turned on or off. If it is off, the successful setup tone will be closed too. TURN OFF KEYBOARD TONE Enter setup state, input: *4*0* When one beep is heard and the LED indicator keeps on for 10 seconds, the setup is successful. TURN ON KEYBOARD TONE Enter setup state, input: *4*1* When one beep is heard and the LED indicator keeps on for 10 seconds, the setup is successful. Note: Default setting: 1, turn on the keyboard tone.
When one beep is heard and the LED indicator keeps on for 10 seconds, the setup is successful. ENABLE RFID READER Enter setup state, input: *5*1* When one beep is heard and the LED indicator keeps on for 10 seconds, the setup is successful. Press [*] on the keypad and then disarm the system by RFID tag after this function was enabled. DISARMING SILENTLY BY RFID TAG The control panel and siren will hoot twice when disarming by RFID tag.
DISABLE DIRECT DISARM BY RFID TAG Enter setup state, input: *7*0* When one beep is heard and the LED indicator keeps on for 10 seconds, the setup is successful. ENABLE DIRECT DISARM BY RFID TAG Enter setup state, input: *7*1* When one beep is heard and the LED indicator keeps on for 10 seconds, the setup is successful. Note: Default setting: 0, disable the function of direct disarm by RFID tag.
When one beep is heard and the LED indicator keeps on for 10 seconds, the setup is successful. Note: User code is 4 digits; default code is “1234”. CHANGE ADMIN CODE Using admin code can wake up keypad, send Arm, Disarm, Stay Mode commands to the control panel, and also change any settings of the keypad. To avoid passcode reveal, please change admin code for first time.
4.USAGE Working with an alarm control panel, the keypad is more secure than the remote control. User code or admin code should be input before the operation of Arm, Disarm, Stay Mode, and Mute Mode. ARM Input user code or admin code, and press key, the LED indicator flashes once and the keypad beeps once and sends [Arm] command to the control panel. When the alarm panel receives the signal, the siren will beep once and the [Arm] indicator will light on. The alarm system enters armed state.
When the alarm panel receives the signal, the siren will beep twice and the Disarm indicator will light on, the alarm system enters disarmed state. In this state, the sensors being triggered will not cause an alarm. USING RFID TAG TO DISARM If direct disarm by RFID tag is disabled, user needs to press [*] to wake up the keypad and then put RFID tag close to the reader to disarm and unlock the door.
EMERGENCY CALL If not inputting code for SOS is set, user just holds the key for 3 seconds, the LED indicator flashes once, the keypad beeps once, and the control panel alarms immediately. If inputting code for SOS is set, user needs to input user code or admin code before holding the [SOS] key for 3 seconds to send an alarm. MUTE MODE Mute mode means that the LED indicators of control panel flash, but the siren does not beep, to avoid disturbing the neighbourhood.
5.NOTICES & MAINTENANCE In order to avoid any harm to the users or others during usage and prolong the usage life, please abide by the following notices. USAGE NOTICES GENERAL INSTRUCTION The keypad should be connected to control panel before use. The power supply of keypad will probably impact on the transmitting distance of wireless signal. The keypad can be powered by 3 pcs of AAA batteries, or wired by DC 12V. The keypad is compatible for any our alarm system.
6.
7.WIRED CABLES INTERFACE (L-R) +12V (RED WIRE): Positive of power GND (BLACK WIRE): Negative of power PUSH (YELLOW WIRE): Signal output for electronic lock GND (WHITE WIRE): Negative of power OPEN (GREEN WIRE): Signal input for exit switch 8.SPECIFICATION Power Supply Static Current: Transmitting Current: Transmitting distance: Radio Frequency: Housing Material: Operations Condition: Keypad Dimensions Weight DC 12V (AAA 1.5V x 3 Pcs) < 20uA < 24mA <80m (in open area) 433.