® Enterprise Electronics Corporation TECHNICAL DOCUMENTATION SET OPERATIONS AND TECHNICAL MANUAL ® RANGER X5 FUNCTIONAL OVERVIEW AND THEORY OF OPERATIONS DESIGNED AND MANUFACTURED FOR: MOBILE CONFIGURATIONS SECTION 1 JOB 9819 EEC • 128 SOUTH INDUSTRIAL BOULEVARD • ENTERPRISE, ALABAMA 36330 TELEPHONE (334) 347-3478 • FAX (334) 393-4556 • www.eecradar.
Official Enterprise Electronics Corporation (EEC) Indemnification Clause The technical data and information (hereinafter “technical data”) contained herein is highly confidential and proprietary in nature and is the sole and exclusive intellectual property of the Enterprise Electronics Corporation ("EEC"). Any company, organization, entity or individual who seeks to benefit from the use of this technical data (“User”) agrees to hold said information in strict confidence.
FCC Part 15.19 Warning Statement- (Required for all Part 15 devices) THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS: (1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION. FCC Part 15.21 Warning Statement NOTE: THE GRANTEE IS NOT RESPONSIBLE FOR ANY CHANGES OR MODIFICATIONS NOT EXPRESSLY APPROVED BY THE PARTY RESPONSIBLE FOR COMPLIANCE.
Revision Information REVISION DATE 1.0 15 November 2014 1.1 3 February 2015 1.2 9 September 2015 MODIFICATION Initial Version Updated with latest technical changes per ECNs Updated with latest changes. Added the INDOOR Cabinet to the manuals. 1.3 7 April 2016 1.4N 31 October 2016 Updated information and graphics for pedestal section. Update for NBC TRUCK Configurations – BRANCH VERSION 1.5A 6 Feb 2017 Pre-Delivery Version for J9819 – part numbers not yet updated. 1.
TABLE OF CONTENTS 1. 1.1. 1.1.1. 1.1.1.1. 1.1.1.2. 1.1.1.3. 1.1.2. 1.1.2.1. 1.1.2.2. 1.1.2.3. 1.1.3. 1.1.4. 1.1.5. 1.1.6. 1.1.7. 1.1.8. 1.1.8.1. 1.1.8.2. 1.1.9. 1.1.10. 1.1.10.1. 1.1.10.2. 1.1.10.3. 1.1.10.4. 1.1.10.5. 1.1.10.6. 1.1.10.7. 1.1.11. 1.1.12. 2. 2.1. 2.1.1. 2.1.1.1. 2.1.1.2. 2.1.2. 2.1.2.1. 2.1.2.2. 2.1.3. 2.1.3.1. 2.1.3.2. 2.1.3.3. 2.1.4. 2.1.4.1. 2.1.4.1.1. 2.1.4.1.2. 2.1.4.1.3. 2.1.4.1.4. 2.1.4.1.5. 2.1.4.2. 2.1.4.2.1. 2.1.4.2.2. 2.1.4.2.3. 2.1.4.2.4. 2.1.4.2.5. 2.1.4.2.6. 2.1.4.2.7. 2.1.4.3.
2.1.4.3.2. 2.1.4.3.3. 2.1.4.3.4. 2.1.4.3.5. 2.1.4.3.6. 2.1.4.3.7. 2.1.4.4. 2.1.4.5. 2.1.5. 2.1.6. 2.1.6.1. 2.1.6.2. 2.1.6.3. 2.1.6.4. 2.1.6.5. 2.2. 3. 4. 4.1. 4.1.1. 4.2. 4.3. 4.3.1. 4.3.2. 4.3.3. 4.3.4. 4.3.5. 4.4. 4.4.1. 4.4.2. 4.5. 4.5.1. 4.5.2. 4.6. 4.6.1. 5. 5.1. 5.1.1. 5.1.1.1. 5.1.2. 5.1.2.1. 5.1.2.2. Vertical UDC / Transmitter Control (Unit 2 A1 A3 A3 A2) ........................................................... 57 Transceiver Power Supply Unit (Unit 2 A1 A3 A3 A3) ...............................
Figure 12. UPS, Powerware Model 9130, (PW9130I2000R-XL) ............................................................................. 19 Figure 13. DC Power Distribution Plate (134932-101) ................................................................................................ 21 Figure 14. Contactor (226-0516) ........................................................................................................................................ 22 Figure 15. Safety Relay (RT6-24VDC) ...............
Figure 110. OpenSuSE (EDGE) Login Screen .............................................................................................................. 91 Figure 111. EDGE A to EDGE B Script ICON ................................................................................................................ 92 Figure 112. EDGE Communications Window................................................................................................................. 92 Figure 113. EDGE Application Icon ...........
PROTECTING PEOPLE AND ASSETS® TECHNICAL DOCUMENTATION INTRODUCTION SYSTEM INTRODUCTION AND OVERVIEW DATE: 27 MARCH 2017 | VERSION: 1.
PROTECTING PEOPLE AND ASSETS® TECHNICAL DOCUMENTATION This page intentionally blank. DATE: 27 MARCH 2017 | VERSION: 1.
PROTECTING PEOPLE AND ASSETS® TECHNICAL DOCUMENTATION The Enterprise Electronics Corporation (EEC) Ranger-X5 radar system is a new generation, Xband (3 cm), Adaptive Polarization Doppler Weather Surveillance Radar that fills the gap between high-cost, high-power traditional radar systems and the passive ground-station weather sensors.
PROTECTING PEOPLE AND ASSETS® TECHNICAL DOCUMENTATION Figure 1. 1.8-Meter Ranger-X5 Variant The standard Ranger-X5 system configuration includes an elevation over azimuth pedestal providing on-board, environmentally sealed, and controlled electronics housing for the transmitters, receivers, and signal digitizer in conjunction with a NEMA 4 grade environmentally controlled ground interface enclosure.
PROTECTING PEOPLE AND ASSETS® TECHNICAL DOCUMENTATION detection sensitivity, bandwidth, dynamic range, measurement accuracy, and useful life. The IQ2-IFD converts the analog receiver IF signals into the digital domain. The IQ2-DSP Digital Signal Processor receives the digitized Inphase / Quadranture (I/Q) data via the PCI receiver card. The I/Q data stream is pre-processed and polar rays of meteorological moments are generated.
PROTECTING PEOPLE AND ASSETS® TECHNICAL DOCUMENTATION This page intentionally blank. DATE: 27 MARCH 2017 | VERSION: 1.
PROTECTING PEOPLE AND ASSETS® TECHNICAL DOCUMENTATION CHAPTER 1 CONTROL CABINET (UNIT 1) DATE: 27 MARCH 2017 | VERSION: 1.
PROTECTING PEOPLE AND ASSETS® TECHNICAL DOCUMENTATION This page intentionally blank. DATE: 27 MARCH 2017 | VERSION: 1.
PROTECTING PEOPLE AND ASSETS® TECHNICAL DOCUMENTATION 1. Control Components The Control Components are mounted in special configurations. The layout is significantly different that cabinet mounted versions of the Ranger-X5 systems. 1.1. Control Components Housing (Unit 1) The Ranger-X5 Control Cabinet houses the Keyboard Video Monitor (KVM), Signal Processor, and Radar Control Unit, Local UPS, Power Controller, DC Power Supplies and the Communications Interface for the radar system.
PROTECTING PEOPLE AND ASSETS® TECHNICAL DOCUMENTATION Figure 3. Control Cabinet (Climate Controlled) – 137043-100 (Rear) 1. 2. 3. 4. 5. 6. 7. 8. 9.
PROTECTING PEOPLE AND ASSETS® TECHNICAL DOCUMENTATION 1. 2. 3. 4. Air Conditioning Unit A/C Circuit Breaker Box GFCI Power Outlet I/O Panel Assembly (135204-100) 1.1.1. RCU with Serial Card (Unit 1 A1) The RCU host computer is a Linux based standard industrial PC that physically converts to Ethernet I/O slave modules to control and monitor radar hardware, using the open industrial standard ModbusTCP for communications.
PROTECTING PEOPLE AND ASSETS® TECHNICAL DOCUMENTATION 1.1.1.1. COBRA RCP Module The COBRA Radar Control Processor (RCP) module controls the radar hardware through a series of coordinated and supervised hardware Analog and Digital control modules. These I/O modules connect to the RCU by Ethernet.
PROTECTING PEOPLE AND ASSETS® TECHNICAL DOCUMENTATION Figure 6. IQ2-DSP Computer (134119-100) 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. Power Switch Power Indicator DVD Drive J7 - Fiber-Optic Connect J8 – Ethernet J6 – Antenna Serial Anglers J10 – PCIe Connect J1 – GPIO J2 – Waveform Generator (Primary) J3 – Waveform Generator (Secondary) J4 – Trigger Output 1.1.2.1.
PROTECTING PEOPLE AND ASSETS® TECHNICAL DOCUMENTATION When processing dual-polarization data, the IQ2-DSP also produces: • • • • • Differential Reflectivity (ZDR) Differential Phase ( DP) Specific Differential Phase (KDP) Correlation Coefficient ( HV) Linear Depolarization Ratio (LDR) Φ Ρ The standard IQ2-DSP algorithms for the horizontally and vertically polarized channels include but are not limited to the following: • • • • • • • • • Thresholding: Noise, SQI 1& 2, SIGPOW, CCOR, & RHOHV Speckle Rem
PROTECTING PEOPLE AND ASSETS® TECHNICAL DOCUMENTATION Figure 7. Keyboard, Video Monitor (132507-100) 1. 2. 3. 4. 5. 6. 7. 17-Inch Display Source Selection Keyboard Touchpad EDGE (V1) RCU (V2) IQ2-DSP (V3) The keyboard has a standard laptop-style touchpad with two command buttons for manipulation of the command cursor and executing operator commands. The display screen is a 17-in. liquid crystal display (LCD) color monitor.
PROTECTING PEOPLE AND ASSETS® TECHNICAL DOCUMENTATION 1.1.4. EDGE Workstation (Unit 1 A4) The EDGE Workstation (see separate EDGE Manual) is a standard computer system nearly identical to the IQ2-DSP computer system. The EDGE software operates on the Linux platform and shares the KVM with the IQ2-DSP and RCU systems. Figure 8. EDGE Workstation, Rack Mount 1. 2. 3. 4. 5.
PROTECTING PEOPLE AND ASSETS® TECHNICAL DOCUMENTATION 1.1.5. 16-Port Gigabit Ethernet Switch (Unit 1 A5) The 16-Port Ethernet Switch provides connectivity between components in the system and the RCU. The 16-Port Ethernet Switch has up to 48 Gbps of bandwidth and can blast 2000 Mbps per port. Each port is equipped with 10/100/1000 automatic speed and full/half-duplex sensing plus Auto Uplink to adjust for straight-through or crossover cables to make the right link. Figure 9.
PROTECTING PEOPLE AND ASSETS® TECHNICAL DOCUMENTATION 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. Setup Port ON LED READY LED Default Button Reset Button Output Status Indicators Branch A Current Usage Branch B Current Usage Branch A Circuit Breakers Branch B Circuit Breakers Branch A Power Inlet Branch B Power Inlet Branch A (A1-A4) Power Outlets Branch B (B1-B4) Power Outlets Alarm LEDs Ethernet Connection 1.1.7.
PROTECTING PEOPLE AND ASSETS® TECHNICAL DOCUMENTATION 1. 2. 3. 4. 1.1.8.1. Terminal Block End Stop (CA702) Fuse Block (3 Each), (CAFL4U) Power Supply, 24 VDC (DPP100-24) Ethernet Switch, 7-Port, 1 FO (EDS-308-M-SC-T) 7-Port Ethernet Switch with 1-Fiber Optic Port (Unit 1 A8 A1) The Ethernet Switch with Fiber-Optic Media Converter provides network access to the RCU computer for the Analog and Discrete Input Modules and converts a fiber-optic connection to Ethernet.
PROTECTING PEOPLE AND ASSETS® TECHNICAL DOCUMENTATION 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19.
PROTECTING PEOPLE AND ASSETS® TECHNICAL DOCUMENTATION Figure 13. DC Power Distribution Plate (134932-101) 1. 2. 3. 4. 5. 6. 7. Lightning Protect Module (A1) - HGLN-CAT6-HP Power Supply, 600W, 24V (PS3) – GEM600-24G Safety Relay (K2) – RT6-24VDC 3-Phase Contactor, 24VDC (K1) – 226-0516 Power Supply, 48VDC, 32A, (PS2) – RSP1500-48 Power Supply, 24VDC (PS1) – DPP50-24 Power Supply, 12VDC (PS4) – DPP30-12 DATE: 27 MARCH 2017 | VERSION: 1.
PROTECTING PEOPLE AND ASSETS® TECHNICAL DOCUMENTATION 1.1.10.1. Lightning Protection Module (Unit 1 A10 A1) (See Figure 13, Point 1) The lighting protection module protects the main Ethernet input from outside the Ranger-X5 radar system. 1.1.10.2. Contactor, 3-Phase, 24VDC (Unit 1 A10 K1) (See Figure 13, Point 4 and Figure 14) The Contactor (K1) receives DC power from the Safety Replay (K2).
PROTECTING PEOPLE AND ASSETS® TECHNICAL DOCUMENTATION Figure 15. Safety Relay (RT6-24VDC) 1.1.10.4. 24VDC Power Supply (Unit 1 A10 PS1) (See Figure 13, Point 6) The 24VDC Power Supply (PS1) is outside of the control of the Emergency Stop System. PS1 provides power to the Safety Replay (RT6), which in turn, controls the AC power supply to the other DC Power Supplies (PS2, PS3, and PS4). 1.1.10.5.
PROTECTING PEOPLE AND ASSETS® TECHNICAL DOCUMENTATION 1.1.10.7. 12VDC Power Supply (Unit 1 A10 PS4) The 12VDC Power Supply (PS4) provides all the 12VDC voltage for the Antenna / Pedestal Assembly. (See Figure 13, Point 7) 1.1.11. E-Stop Panel (Unit 1 A11) The E-Stop Control panel contains the E-Stop Reset button, the E-Stop Button, Power Indicators, and two Circuit Breakers. The Main Power circuit breaker (CB1) controls power to the entire system.
PROTECTING PEOPLE AND ASSETS® TECHNICAL DOCUMENTATION 1.1.12. I/O Panel Assembly (Unit 1 A12) The Indoor Control Cabinet is equipped with an I/O Panel Assembly to connect the Control Cabinet to the Pedestal Unit. The AC Input for the Outdoor Control Cabinet is through a standard, commercial grade circuit breaker box. Figure 17. I/O Panel Assembly, 19-inch Rack (134938-100) 1. 2. 3. 4. 5. 6.