User's Manual

Ensemble Communications Inc.
6-4
Operator’s Guide to the Fiberless System
ODU Installation
Note Installers are responsible for supplying mounting bolts.
Ground Mast All steel mounting structures attached to the building and the
antenna mast must be connected to the building grounding
system. If no grounding system or ring is available, ground the
antenna mounting structures to the nearest structural beam. The
grounding conductor should be set at least a # 2 (AWG) solid
tinned copper wire. Use exothermic welds (Cad Welds) when
possible to connect to the mounting structure and the building
grounding system.
Antenna Mounting 1. Attach the ODU mounting bracket to a mast between 2- and 4-
inches in diameter (1 in Figure 6-1).
2. Remove the nuts and washers (2 in Figure 6-1) from one side of
each of the two mounting clamps (3) and slide the mounting
clamps off the bolts. Set them aside in a safe place.
3. Slip the mounting rack (4 in Figure 6-1) around the mast.
4. Reattach each of the two mounting clamps with the flat washer,
lock washer, and nut.
5. Tighten with a 1/2-inch socket wrench until secure.