USER MANUAL V1.2 Transmitter Module PTM 33x / PTM 33xC / PTM 330U May 16, 2013 Observe precautions! Electrostatic sensitive devices! Patent protected: WO98/36395, DE 100 25 561, DE 101 50 128, WO 2004/051591, DE 103 01 678 A1, DE 10309334, WO 04/109236, WO 05/096482, WO 02/095707, US 6,747,573, US 7,019,241 EnOcean GmbH Kolpingring 18a 82041 Oberhaching Germany Phone +49.89.67 34 689-0 Fax +49.89.67 34 689-50 info@enocean.com www.enocean.
USER MANUAL V1.2 PTM 33X / PTM 33XC / PTM 330U REVISION HISTORY The following major modifications and improvements have been made to the first version of this document: No 0.81 0.85 0.90 1.00 1.01 1.02 1.03 1.10 1.2 Major Changes CFG Pin: For test purposes only Antenna length 868 MHz changed to 86 mm; upper limit of operating temperature reduced to 65 °C Equivalent energy pulse definition added Max. supply voltage for programming interface added in 2.4. Digital input parameters added in 2.3.
USER MANUAL V1.2 PTM 33X / PTM 33XC / PTM 330U TABLE OF CONTENT 1 RELATED DOCUMENTS ................................................................................... 4 2 2.1 2.2 2.3 2.4 2.5 3 FUNCTIONAL DESCRIPTION ............................................................................ 7 3.1 Block diagram ............................................................................................... 7 3.2 Pin out ..................................................................................
USER MANUAL V1.2 PTM 33X / PTM 33XC / PTM 330U 1 RELATED DOCUMENTS In addition to this document additional information is available on our web site: Proposal for mechanical integration with ECO 200 in 2D and 3D format Footprint with positions of pads available in Protel and Gerber format AN102: Antenna Basics – Basic antenna design considerations for EnOcean based products 2 GENERAL DESCRIPTION 2.
USER MANUAL V1.2 PTM 33X / PTM 33XC / PTM 330U 2.3 Physical Dimensions PCB dimensions © 2010 EnOcean | www.enocean.com 26.2 x 21.15 x 3.5 mm PTM 33x / PTM 33xC / PTM 330U User Manual V1.
USER MANUAL V1.2 PTM 33X / PTM 33XC / PTM 330U 2.4 Environmental Conditions Operating temperature -25 °C … +65 °C Storage temperature -40 °C … +85 °C Storage temperature in Tape&Reel -20 °C … +50 °C Humidity 2.5 0% … 93% r.h., non-condensing Ordering Information Type Ordering Code PTM 330 S3001-A330 PTM 332 S3001-A332 PTM 330C S3031-A330 PTM 332C S3031-A332 PTM 330U S3051-A330 © 2010 EnOcean | www.enocean.com Frequency 868.3 MHz 868.3 MHz 315.0 MHz 315.0 MHz 902.
USER MANUAL V1.2 PTM 33X / PTM 33XC / PTM 330U 3 FUNCTIONAL DESCRIPTION 3.1 Block diagram At power-up by an energy pulse at AC1, AC2 a DC voltage is provided to the internal micro controller. The microcontroller reads the polarity of the supply voltage pulse and the status of the digital inputs A0, A1, B0, B1. After that 3 identical radio telegrams calculated from the status of these inputs are transmitted. PTM33x CFG A0 A1 RF_WHIP B0 µC B1 RF GND GND 3.
USER MANUAL V1.2 PTM 33X / PTM 33XC / PTM 330U 3.
USER MANUAL V1.2 PTM 33X / PTM 33XC / PTM 330U 3.4 Configuration Interface Via the programming interface the telegram content can be modified.
USER MANUAL V1.2 PTM 33X / PTM 33XC / PTM 330U 3.6 Maximum Ratings (operating) Symbol AC1 AC2 GND A0 A1 B0 B1 Parameter Supply voltage Ground connection Min 0 0 0 Max 6.0 0 0 Units V V V Voltage digital input pins © 2010 EnOcean | www.enocean.com PTM 33x / PTM 33xC / PTM 330U User Manual V1.
USER MANUAL V1.2 PTM 33X / PTM 33XC / PTM 330U 3.7 Radio telegram 3.7.1 Normal operation In default configuration PTM 33x transmits the same telegrams as a PTM 200 radio switch: Telegram type RPS: There are two message types depending on how many buttons (A0, A1, B0, B1) have been pressed (connected to GND) o N-message: Only one or two buttons have been pressed. o U-message: No pushbutton was pressed when activating the energy generator, or more than two pushbuttons have been pressed.
USER MANUAL V1.2 PTM 33X / PTM 33XC / PTM 330U U-message: DATA_BYTE3: 7 0 BUTTONS BUTTONS PR Reserved (3 bit) Number of simultaneously pressed buttons, as following: 0 = 0 Button 1 = not possible 2 = not possible 3 = 3 or 4 buttons 4 = not possible 5 = not possible 6 = not possible 7 = not possible PO Reserved (1 bit) (4 bit) Polarity, see table below STATUS: 7 Reserved 0 T21 Reserved T21 NU RP_COUNTER NU (2 (1 (1 (4 RP_COUNTER bit) bit) bit) bit) For future use 1 NU=0 U-message.
USER MANUAL V1.2 PTM 33X / PTM 33XC / PTM 330U 4 APPLICATIONS INFORMATION 4.1 How to connect an energy harvester PTM 330 can be connected to ECO 200 without soldering. ECO 200 provides contact springs which can directly be connected to contact pads of PTM 330. The contact pads on the bottom of the PCB are shown below (left). A second orientation where PTM 330 is rotated 180° with respect to ECO 200 is also possible as shown with dashed lines. 4.
USER MANUAL V1.2 PTM 33X / PTM 33XC / PTM 330U 4.3 Antenna 315 MHz Option 1: 150 mm wire, connect to RF_WHIP Option 2: A 50 Ω antenna can be connected to RF_50.
USER MANUAL V1.2 PTM 33X / PTM 33XC / PTM 330U 4.4 Layout recommendations Proposal for foot print on host PCB Keep out area on host PCB. No copper surface area allowed! © 2010 EnOcean | www.enocean.com PTM 33x / PTM 33xC / PTM 330U User Manual V1.
USER MANUAL V1.2 PTM 33X / PTM 33XC / PTM 330U 4.5 Soldering information PTM 332/332C PTM 332 has to be soldered according to IPC/JEDEC J-STD-020C standard. PTM 332 shall be handled according to Moisture Sensitivity Level MSL4 which means a floor time of 72 h. PTM 332 may be soldered only once, since one time is already consumed at production of the module itself. Once the dry pack bag is opened, the desired quantity of units should be removed and the bag resealed within two hours.
USER MANUAL V1.2 PTM 33X / PTM 33XC / PTM 330U 4.6 Transmission range The main factors that influence the system transmission range are type and location of the antennas of the receiver and the transmitter, type of terrain and degree of obstruction of the link path, sources of interference affecting the receiver, and “Dead” spots caused by signal reflections from nearby conductive objects.
USER MANUAL V1.2 PTM 33X / PTM 33XC / PTM 330U 5 AGENCY CERTIFICATIONS The modules have been tested to fulfil the approval requirements for CE (PTM 33x) and FCC/IC (PTM 33xC, PTM 330U) based on the built-in firmware. 5.1 CE approval The modules bear the EC conformity marking CE and conform to the R&TTE EU-directive on radio equipment. The assembly conforms to the European and national requirements of electromagnetic compatibility.
USER MANUAL V1.2 PTM 33X / PTM 33XC / PTM 330U 5.2 FCC (United States) Certification 5.2.1 PTM 330C and PTM 332C FCC LIMITED MODULAR APPROVAL This is an RF module approved for Limited Modular use operating as an intentional transmitting device with respect to 47 CFR 15.231(a-c) and is limited to OEM installation. The module is optimized to operate using small amounts of energy, and may be powered by a battery.
USER MANUAL V1.2 PTM 33X / PTM 33XC / PTM 330U OEM Requirements In order to use EnOcean’s FCC ID number, the OEM must ensure that the following conditions are met: End users of products, which contain the module, must not have the ability to alter the firmware that governs the operation of the module. The agency grant is valid only when the module is incorporated into a final product by OEM integrators. The end-user must not be provided with instructions to remove, adjust or install the module.
USER MANUAL V1.2 PTM 33X / PTM 33XC / PTM 330U 5.2.2 PTM 330C and PTM 332C FCC LIMITED MODULAR APPROVAL Certificate © 2010 EnOcean | www.enocean.com PTM 33x / PTM 33xC / PTM 330U User Manual V1.
USER MANUAL V1.2 PTM 33X / PTM 33XC / PTM 330U 5.2.3 PTM 330U FCC (United States) Single Transmitter Approval PTM 330U is an RF module approved by the FCC as Single Transmitter with the following ID: FCC ID: SZV-PTM330U The Original Equipment Manufacturer (OEM) must ensure that FCC labeling requirements are met. This includes a clearly visible label on the outside of the final product. Attaching a label to a removable portion of the final product, such as a battery cover, is not permitted.
USER MANUAL V1.2 PTM 33X / PTM 33XC / PTM 330U 5.2.4 FCC (United States) Regulatory Statements This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any changes or modifications not expressly approved by manufacturer could void the user’s authority to operate the equipment.
USER MANUAL V1.2 PTM 33X / PTM 33XC / PTM 330U 5.3 IC (Industry Canada) Certification 5.3.1 PTM 330C and PTM 332C IC (Industry Canada) Certification PTM 330C and PTM 332C have been granted an IC number as outlined below: IC: 5713A-PTM33XC In order to use EnOcean’s IC number, the OEM must ensure that the following conditions are met: Labeling requirements for Industry Canada are similar to those required by the FCC.
USER MANUAL V1.2 PTM 33X / PTM 33XC / PTM 330U 5.3.2 PTM 330C / PTM 332C Industry Canada Certification Document © 2010 EnOcean | www.enocean.com PTM 33x / PTM 33xC / PTM 330U User Manual V1.
USER MANUAL V1.2 PTM 33X / PTM 33XC / PTM 330U 5.3.3 PTM 330U IC (Industry Canada) Certification PTM 330U has been granted an IC number as outlined below: IC: 5713A-PTM330U Labeling requirements for Industry Canada are similar to those required by the FCC. The Original Equipment Manufacturer (OEM) must ensure that IC labeling requirements are met.
USER MANUAL V1.2 PTM 33X / PTM 33XC / PTM 330U 5.3.4 Industry Canada Regulatory Statements This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.